/

SonoLong SoftSecure-Catheter Placement for Peripheral Nerve Blocks

$0.00

Shipped From Abroad

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: Pajunk

Description

Clinical Requirements – Precision in Catheter Placement

Precise and permanent placement of the catheter is of crucial importance for reliable performance of peripheral nerve blocks. Marhofer et al.1 have analyzed the causes and consequences of catheter misplacement in detail. Among other things, they found a highly significant correlation between dwell time and dislocation rate of the catheter for interscalene and femoral nerves.

Primary dislocation
If the catheter is pushed further through the nerve, the anesthetic not only misses its target area, but serious complications such as injury to nerve structures and blood vessels can also occur.

Secondary dislocation
Early mobilization of patients also carries the risk of catheter migration. This can damage vessels or nerves and the effectiveness of regional anesthesia cannot be guaranteed.

Relevance of the Catheter Material – Atraumatic, Flexible Catheter Tip

An important starting point for reducing the dislocation rate is the quality of the catheter tip. In 2012, Shih et al. found a direct correlation between the stiffness of the catheter material and the dislocation rate during epidural block.2

This is exactly where the PAJUNK® development started off from. The result is the SonoLong SoftSecure catheter, which is characterized by a soft catheter material and is equipped with a stylet, a stainless steel spiral, and three lateral openings.

The soft tip of the SonoLong SoftSecure catheter ensures precise placement, as the tip is deflected away from the nerve wall due to the wall’s resistance.

For the same reason, the catheter is also held back by the surrounding, firmer structures of the fascia and rolls up in the immediate vicinity. Further advancement of the catheter and subsequent dislocation during patient mobilization should be avoided.

SonoLong SoftSecure Catheter Features & Advantages

Soft Catheter Material

Makes the tip soft and flexible:

  • Designed to minimize the primary and secondary dislocation rates.
  • Injury to nerve structures and blood vessels can be prevented from occurring.

Markings and Graduations

Outlet markings for the SonoLong needle 50 mm, 100 mm, 150 mm, and six ascending 360° markings in 5 cm increments up to 30 cm:

  • Indicate where the catheter tip exits the needle.
  • Support easy control of catheter position.

Catheter Container with Integrated Insertion Aid

Supports one-handed catheter insertion through the needle and tactile perception:

  • Catheter placement is possible under sterile conditions since the catheter is protected by the catheter container.
  • Memory effect can be avoided.

Three Lateral Openings

Arranged around the first 1.1 cm, the tip is closed:

  • Optimize even distribution of the anesthetic.

Stylet Ensures Stability

Stylet is set back 5 cm from the distal end:

  • Supports convenient and secure placement.
  • The soft catheter tip maintains its atraumatic properties.

Integrated Stainless Steel Helical Coil

Ensures kink resistance and flexibility, and a stable inner lumen3.

  • Enables a high anesthetic flow rate
  • and a smooth connection to the injection pump.
SonoLong NanoLine® Needle Features & Advantages

Cornerstone Reflectors

360° graduations on the first 20 mm of the needle in two sections:

  • Optimized ultrasound visibility of the needle shaft4.
  • Reliable and optimized needle echogenicity at higher insertion angles.

NanoLine Coating

Ultra-thin polymer layer in the inner and outer lumen:

  • Increased stimulation precision only through the non-insulated needle tip.

Click here to download Brochure

Reviews

There are no reviews yet.

Be the first to review “SonoLong SoftSecure-Catheter Placement for Peripheral Nerve Blocks”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsSonoLong SoftSecure-Catheter Placement for Peripheral Nerve Blocks removeFlowMir Disposable Turbine with Cardboard Mouthpiece removeFoyomed Nasal Oxygen Cannula removeCouch Cover removeAmbu Bag with Reservior removeHearing Aid remove
NameSonoLong SoftSecure-Catheter Placement for Peripheral Nerve Blocks removeFlowMir Disposable Turbine with Cardboard Mouthpiece removeFoyomed Nasal Oxygen Cannula removeCouch Cover removeAmbu Bag with Reservior removeHearing Aid remove
ImageFlowMir Disposable Turbine with Cardboard Mouthpiece
SKUSF1033560084-22SF1033560084-24SF1033560084-66SF1033560084-41SF1033560084-119
Rating
Price

$0.00

$145.00

$1.30

$8.50

$17.00

$16.90

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Spirometry testing requires maximum accuracy and hygiene. Each Flowmir disposable turbine, which includes a cardboard mouthpiece, has been individually factory calibrated with a computerized system and it is packaged individually. FlowMIR® is an inexpensive alternative to a costly reusable flowmeter and replaces the need for an antibacterial filter Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

In Stock

Foyomed Nasal Oxygen Cannula: The nasal cannula are used for patients needing only low-flow supplemental oxygen.  Patients with breathing difficulties and conditions such as emphysema or other pulmonary pathologies require the nasal cannula.  The flow rate for the cannula is around .5 to 4 liters per minute (LPM). All materials used in construction of the Oxygen Mask ,and the Oxygen Tubing are latex free, soft and smooth surface without sharp edge and object, They have no undesirable effects on the Oxygen/Medication passing through under ordinary conditions of use. Mask Material are hypoallergenic and shall resist ignition and rapid buring. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
In stock Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
Ambu Bag with Reservior: The ventilation bag is highly reactive with fast recoil and excellent stroke volume which help relieving fatigue to the rescuer. The thin-walled compression bag provides an excellent feel of lung compliance and helps avoid excessive ventilation that could damage the lungs.
  Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Material: Plastic
  • Sales Package - 1 Hearing Aid, Ear Plugs With 12 Batteries
  • Full-on Gain 50 dB, Frequency Range 300-4000 Hz, Equivalent Input Noise 30 dB
  • Battery Type: P675.
  • Please read the operation/manual instruction before using the product.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Clinical Requirements - Precision in Catheter Placement
Precise and permanent placement of the catheter is of crucial importance for reliable performance of peripheral nerve blocks. Marhofer et al.1 have analyzed the causes and consequences of catheter misplacement in detail. Among other things, they found a highly significant correlation between dwell time and dislocation rate of the catheter for interscalene and femoral nerves. Primary dislocation If the catheter is pushed further through the nerve, the anesthetic not only misses its target area, but serious complications such as injury to nerve structures and blood vessels can also occur. Secondary dislocation Early mobilization of patients also carries the risk of catheter migration. This can damage vessels or nerves and the effectiveness of regional anesthesia cannot be guaranteed.
Relevance of the Catheter Material - Atraumatic, Flexible Catheter Tip
An important starting point for reducing the dislocation rate is the quality of the catheter tip. In 2012, Shih et al. found a direct correlation between the stiffness of the catheter material and the dislocation rate during epidural block.2 This is exactly where the PAJUNK® development started off from. The result is the SonoLong SoftSecure catheter, which is characterized by a soft catheter material and is equipped with a stylet, a stainless steel spiral, and three lateral openings. The soft tip of the SonoLong SoftSecure catheter ensures precise placement, as the tip is deflected away from the nerve wall due to the wall's resistance. For the same reason, the catheter is also held back by the surrounding, firmer structures of the fascia and rolls up in the immediate vicinity. Further advancement of the catheter and subsequent dislocation during patient mobilization should be avoided.
SonoLong SoftSecure Catheter Features & Advantages

Soft Catheter Material

Makes the tip soft and flexible:
  • Designed to minimize the primary and secondary dislocation rates.
  • Injury to nerve structures and blood vessels can be prevented from occurring.

Markings and Graduations

Outlet markings for the SonoLong needle 50 mm, 100 mm, 150 mm, and six ascending 360° markings in 5 cm increments up to 30 cm:
  • Indicate where the catheter tip exits the needle.
  • Support easy control of catheter position.
Catheter Container with Integrated Insertion Aid
Supports one-handed catheter insertion through the needle and tactile perception:
  • Catheter placement is possible under sterile conditions since the catheter is protected by the catheter container.
  • Memory effect can be avoided.
Three Lateral Openings
Arranged around the first 1.1 cm, the tip is closed:
  • Optimize even distribution of the anesthetic.

Stylet Ensures Stability

Stylet is set back 5 cm from the distal end:
  • Supports convenient and secure placement.
  • The soft catheter tip maintains its atraumatic properties.
Integrated Stainless Steel Helical Coil
Ensures kink resistance and flexibility, and a stable inner lumen3.
  • Enables a high anesthetic flow rate
  • and a smooth connection to the injection pump.
SonoLong NanoLine® Needle Features & Advantages
Cornerstone Reflectors
360° graduations on the first 20 mm of the needle in two sections:
  • Optimized ultrasound visibility of the needle shaft4.
  • Reliable and optimized needle echogenicity at higher insertion angles.
NanoLine Coating
Ultra-thin polymer layer in the inner and outer lumen:
  • Increased stimulation precision only through the non-insulated needle tip.

Click here to download Brochure

    • Comfortable Packaging
    • Singularly Tested and Packed
    • Always 100% accurate and hygienic
    • No Calibration required
    • No Sterilization required
    • No Antibacterial Filter required
    • No Cross Contamination
    • Not affected by Vapour Condensation
    • Not affected by Ambient conditions
    •  A full Spirometry session can be performed, including a Bronchial Challenge and POST Bronchodilator test. For each patient after the Spirometry test, both turbine and spirometer mouthpiece are thrown away
    • .
   
Foyomed Nasal Oxygen Cannula: The nasal cannula are used for patients needing only low-flow supplemental oxygen.  Patients with breathing difficulties and conditions such as emphysema or other pulmonary pathologies require the nasal cannula.  The flow rate for the cannula is around .5 to 4 liters per minute (LPM). All materials used in construction of the Oxygen Mask ,and the Oxygen Tubing are latex free, soft and smooth surface without sharp edge and object, They have no undesirable effects on the Oxygen/Medication passing through under ordinary conditions of use. Mask Material are hypoallergenic and shall resist ignition and rapid buring. Features:
  • Material: clear, non-toxic PVC.
  • A single-use, disposable nasal cannula.
  • A highly flexible and lightweight piece with two prongs.
  • Comes in an over-the-ear design to ensure premium comfort.
  • Available with an anti-crush, 7 ft tubing.
  • Different types of prongs are available.
  • A must-have medical equipment for hospitals and more.
 
   
Ambu Bag with Reservior: The ventilation bag is highly reactive with fast recoil and excellent stroke volume which help relieving fatigue to the rescuer. The thin-walled compression bag provides an excellent feel of lung compliance and helps avoid excessive ventilation that could damage the lungs.
Features:
  • Brand: OEM
  • Item No.: AM-DMR-M06-0/1/4
  • Color: Green
  • Size: Adult/Pediatric/Infant
  • Material: Disposable
  • Application: Emergency Resuscitation
  • MOQ: 300
  • Lead Time: 60 days
  • Shipping Terms: FOB
  • Packaging Details: Each set is packed into a white PP box
  • Carton Size: 57 x 34 x 46 CM / 12 SETS
  • Shipping Weight: 9.8 Kilos
  Technical Specifications:
Type Infant Pediatric Adult
Patient weight ≤10kg 10kg-40kg >40kg
Stroke volume 150ml 400ml 800ml
Resuscitator volume 280ml 600ml 1650ml
Dimensions L x D 135 x 75mm 146 x 100mm 212 x 131mm
Resuscitator weight 350g 410g 600g
Pressure limiting valve 40cmH2O 40cmH2O 60cmH2O
Inspiratory resistance <5cmH2O (at 50L/min)
Expiratory resistance <5cmH2O (at 50L/min)
Bag volume 1600ml 1600ml 2000ml
Patient connector ISO5356-1:φ22/15mm Male/Female
Recommended operating temperature -18℃~+50℃
Storage Tested at -40℃ and 60℃
 
 
  • Material: Plastic
  • Sales Package - 1 Hearing Aid, Ear Plugs With 12 Batteries
  • Full-on Gain 50 dB, Frequency Range 300-4000 Hz, Equivalent Input Noise 30 dB
  • Battery Type: P675.
  • Please read the operation/manual instruction before using the product.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare