STERIPLUS 80
$0.00
Shipped From Abroad
INTEGRATED INFECTIOUS WASTE PRE-SHREDDING AND STEAM STERILIZATION SYSTEM
Tesalys STERIPLUS ™ systems are the ideal solution to safely inactivate your infectious waste on site. Their integrated TESASHRED ™ shredding system not only allows a consequent reduction in the volume and weight of waste, but also guarantees their treatment at heart.
Click here to download Catalogue
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
STERIPLUS 80
On-site infectious risk waste treatment solution
Features
Fully automated
The STERIPLUS™ 80 is an easy-to-use, on-site processing solution.
Large capacity
The loading chamber has a capacity of 80 litres, i.e. 1 TESABOX 80 or 2 TESABOX 40 or 4 TESABOX 20.
Fully integrated system
The STERIPLUS™ 80 is a fully automated solution for pre-grinding and steam sterilization of infectious wastes.
Technical Data
LOADING CHAMBER CAPACITY | 80 L |
LOADING CHAMBER USEFUL DIMENSIONS (W x D x H) | 370 x 360 x 628 mm |
LOADING CAPACITY (containers) | 1 X TESABOX 80 or 2 X TESABOX 40 or 4 X TESABOX 20 |
TOTAL CYCLE TIME (NF X30-503-1 standard) (1) | 30 to 35 min |
TOTAL CYCLE TIME in working conditions (2) | 30 to 50 min. |
LOADING CAPACITY (KG/CYCLE) | 6,4 to 9,6 kg/cycle – Based on an average waste density of 0,08 to 0,12kg/L for HealthCare Waste 9,6 to 16 kg/cycle- Based on an average waste density of 0,12 to 0,2kg/L for Lab/Humid/Liquid |
TREATMENT CAPACITY (KG/H) (3) | 8 to 12 kg/h – Based on an average waste density of 0,08 to 0,12kg/L for HealthCare Waste 12 to 20 kg/h – Based on an average waste density of 0,12 to 0,2kg/L for Lab/Humid/Liquid |
MAX QUANTITY OF LIQUID RECOMMENDED PER CYCLE (4) | 24 L |
EXTERNAL DIMENSIONS (w x d x h) | 1550 x 1200 x 1800 mm |
NET WEIGHT | 1300 kg |
LOADING CHAMBER | Stainless steel with PTFE coating |
TREATMENT CHAMBER | AISI 304L stainless steel |
STEAM GENERATOR | AISI 304L stainless steel (chamber) & Highly corrosion-resistant Hastelloy® |
WATER SOFTENER | Built-in |
WATER BOOSTER PUMP AND AIR COMPRESSOR | Built-in |
WASTER SHREDDER | Structure: AISI 304L stainless steel & Blades: High-strength steel |
PIPING | Stainless steel/PTFE flexible hosing |
CHASSIS | Painted steel |
BODYWORK | Composite material / Painted steel |
CYCLE TRACEABILITY – THROUGH PRINTOUT | Built-in |
USB PORT | Built-in |
Utilities
WATER | |
Requirements | Softened water (4-8°TH) |
Consumption | 15 liters / cycle |
ELECTRICITY | |
Requirements | 380-400 V III N, 50Hz/60Hz, 20 kW |
Consumption | 3 kWh/cycle |
DRAIN | ø 32 mm internal (heat-resistant) |
STEAM/COMPRESSED AIR | Produced by the integrated steam generator and air compressor; no external connection required. |
Accessories
- Maintenance parts kit STERIPLUSTM
- System waste unloading system
- Adaptation to different voltages / frequencies
- Special packaging
Quick Comparison
STERIPLUS 80 remove | Keewell Gel Warmer KGW-1 remove | Keewell Gel Warmer KGW-2 remove | BEING BBC-3S1 Biosafety Cabinet remove | Genoray OSCAR 15 Surgical C-Arm Machine remove | ADE M501660 Wheelchair Scale remove | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | STERIPLUS 80 remove | Keewell Gel Warmer KGW-1 remove | Keewell Gel Warmer KGW-2 remove | BEING BBC-3S1 Biosafety Cabinet remove | Genoray OSCAR 15 Surgical C-Arm Machine remove | ADE M501660 Wheelchair Scale remove | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SKU | SF103356013097-3 | SF1033560085 | SF1033560086 | SF1033560101 | SF1033560422-1 | SF1033560099 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Price |
| $153.00 | $175.00 |
|
|
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Stock | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Availability | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Description | Shipped From Abroad
INTEGRATED INFECTIOUS WASTE PRE-SHREDDING AND STEAM STERILIZATION SYSTEM
Tesalys STERIPLUS ™ systems are the ideal solution to safely inactivate your infectious waste on site. Their integrated TESASHRED ™ shredding system not only allows a consequent reduction in the volume and weight of waste, but also guarantees their treatment at heart.
Click here to download CatalogueDelivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
A typical complaint in ultrasound procedures is the cold ultrasound gel. This device can safely heat the ultrasound gel to the body temperature.
By this way it can remove the uncomfortable cold feeling of the patients, help the patients more relaxation to the diagnosis. At the same time, it can also improve the performance of the ultrasound gel, increase the image and signal quality.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
A typical complaint in ultrasound procedures is the cold ultrasound gel. This device can safely heat the ultrasound gel to the body temperature.
By this way it can remove the uncomfortable cold feeling of the patients, help the patients more relaxation to the diagnosis. At the same time, it can also improve the performance of the ultrasound gel, increase the image and signal quality.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
This product has a front window operation port, through which the operator can operate inside the safety cabinet. The negative pressure air inhaled from the front window operation port is used to protect the safety of the operator; the downflow filtered by the high efficiency filter is used to protect the experimental articles in the safety cabinet; the air flow filtered by the high efficiency filter is discharged from the safety cabinet to protect the environment.
Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from Abroad The OSCAR 15 is a culmination of several years worth of developmental experience from Genoray. With CMOS imaging excellence & 15kW HFG you diagnosis need will be met while improving your productivity especially DSA (Digital Subtraction Angiography). Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Abroad
Electronic wheelchair scale with integrated ramps on both sides. Two handgrips and transport castors allow an easy handling of the scale. The all steel construction provides extra stability and takes weight up to 300 kg.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Content | STERIPLUS 80On-site infectious risk waste treatment solutionhttps://youtu.be/ahPvNNrzIMk?si=8dLL5Pn1YWY_sUM7![]() ![]() ![]() FeaturesFully automated
The STERIPLUS™ 80 is an easy-to-use, on-site processing solution.
Large capacity
The loading chamber has a capacity of 80 litres, i.e. 1 TESABOX 80 or 2 TESABOX 40 or 4 TESABOX 20.
Fully integrated system
The STERIPLUS™ 80 is a fully automated solution for pre-grinding and steam sterilization of infectious wastes.
Technical Data
Utilities
Accessories | A typical complaint in ultrasound procedures is the cold ultrasound gel. This device can safely heat the ultrasound gel to the body temperature. By this way it can remove the uncomfortable cold feeling of the patients, help the patients more relaxation to the diagnosis. At the same time, it can also improve the performance of the ultrasound gel, increase the image and signal quality. FEATURES: High bright LED display Adjustable temperature control range 34-40℃ Programmable timer to switch on and switch off 360 degree surround heater unit Digital temperature control technology High energy efficiency Ergonomic design Built-in durable waIl mountable construction STANDARDS CONFORMED TO: EN 55014-1: 2006+A1:2009 EN 55014-2: 1997+A2:2008 EN 61000-3-2: 2006+A2:2009 EN 61000-3-3: 2008 EN 60335-1: 2002+A1:2004+A11:2004+A12:2006+A2:2006+A13:2008+A14:2010 EN 62233:2008 SPECIFICATIONS: Power Supply: AC100-240V, 50/60Hz, 30VA; DC12V, 2A Operating Ambient Temperature: 0-40℃ Operating Relative Humidity: 30-90% Temperature Control Range: 34-40℃ Temperature Control Accuracy: ± 1℃ (After Heat Balance) Auto Switch On Timer: 00:00-23:59 Auto Switch Off Timer: 00:00-23:59 | A typical complaint in ultrasound procedures is the cold ultrasound gel. This device can safely heat the ultrasound gel to the body temperature. By this way it can remove the uncomfortable cold feeling of the patients, help the patients more relaxation to the diagnosis. At the same time, it can also improve the performance of the ultrasound gel, increase the image and signal quality. FEATURES: High bright LED display Adjustable temperature control range 34-40℃ Programmable timer to switch on and switch off 360 degree surround heater unit Digital temperature control technology High energy efficiency Ergonomic design Built-in durable waIl mountable construction STANDARDS CONFORMED TO: EN 55014-1: 2006+A1:2009 EN 55014-2: 1997+A2:2008 EN 61000-3-2: 2006+A2:2009 EN 61000-3-3: 2008 EN 60335-1: 2002+A1:2004+A11:2004+A12:2006+A2:2006+A13:2008+A14:2010 EN 62233:2008 SPECIFICATIONS: Power Supply: AC100-240V, 50/60Hz, 30VA; DC12V, 2A Operating Ambient Temperature: 0-40℃ Operating Relative Humidity: 30-90% Temperature Control Range: 34-40℃ Temperature Control Accuracy: ± 1℃ (After Heat Balance) Auto Switch On Timer: 00:00-23:59 Auto Switch Off Timer: 00:00-23:59 | This product has a front window operation port, through which the operator can operate inside the safety cabinet. The negative pressure air inhaled from the front window operation port is used to protect the safety of the operator; the downflow filtered by the high efficiency filter is used to protect the experimental articles in the safety cabinet; the air flow filtered by the high efficiency filter is discharged from the safety cabinet to protect the environment.
Features:
LCD large screen
Ergonomic 5 ° inclination design
Backlight design to relieve eyesight fatigue
Platform type hand rest
304 stainless steel liner
Timing function
Easy to clean and disinfect
Technical Specification:
Internal Dimensions (W×D×H) mm: 920×580×655
External Dimensions (W×D×H) mm: 1040×810×2100
Downflow Velocity: 0.33m/s
Inflow Velocity: 0.33m/s
Working Access Opening Height: 200mm
Opening MAX.: 450mm
HEPA Filter Typical Efficiency: 99.99% @ 0.3µm
Noise: <65dB
Fluorescent Lamp Intensity: >900Lux
| The OSCAR 15 is a culmination of several years worth of developmental experience from Genoray. With CMOS imaging excellence & 15kW HFG you diagnosis need will be met while improving your productivity especially DSA (Digital Subtraction Angiography).
APPLICATION
Click Here To Download Catalogue | Electronic wheelchair scale with integrated ramps on both sides. Two handgrips and transport castors allow an easy handling of the scale. The all steel construction provides extra stability and takes weight up to 300 kg.
Features:
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Weight | N/A | N/A | 50 kg | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Dimensions | N/A | N/A | 120 × 350 × 150 cm | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Additional information |
|
Reviews
There are no reviews yet.