SURTRON 400 HP

$0.00

Shipped From Abroad

SURTRON 400 HP can be used to simultaneously perform monopolar and bipolar surgery in application fields that require high precision and reliability.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: LED Surtron

Description

Features

DOUBLE ACTIVITY ‘OPERATION
• Two output channels for monopolar cutting
• Two independent settings and output channels for monopolar coagulation are more frequent

CONTROLLED CUTTING PROCEDURES
• cutting currents for eschar-free incision
• Cutting current with selectable coagulating property for bleeding-controlled dissection
• Low capacitive coupling by current endoscopic procedures, Slow BLEND

DOUBLE PROCEDURES SUBSIDIARIES COAGULATION
• SPEEDY Coag Coag DEEP ** * and two operators
• SPRAY COAG is achievable with a handpiece or pedal

WIDE BIPOLAR FEATURES
• Bipolar cutting with bleeding control
• Cutting current Slow BLEND
• Start and stop automatically activate separately

TOTAL SAFETY FOR PATIENT AND SURGEON
• Acceptability of contact impedance between the patient’s body and the neutral plate is constantly verified by the electronic control Skin Plate Electronic Control called SPEC
• Continuous monitoring of leakage current
• Change in automatically compensated mains voltage before starting the RF power output

CUSTOM PROCEDURES
• Independent choice of coagulation currents and power levels of each of the two operators
• Ten configurable personal procedures and immediately recallable

CONDUCT OF EXTENSIONS AND SIGNAL CONNECTION
• outputs for connections driven by argon plasma units and smoke aspirator

AUTOMATIC SELF-DIAGNOSIS WITH SURTRON 400 HP
• Automatic diagnostic control of the actual complete electronic drive functionality and accessories, connected and coded report of found failures

* Coag SPEEDY is also called Fulgurate or Forced
** Coag DEEP is also called Pin Point, Desicate, or Soft

 

Technical Data
  • Max output power monopolar pure CUT
    400 W – 300 Ω
  • Max output power monopolar cut-coag CUT80%
    300 W – 300 Ω
  • Max output power monopolar cut-coag CUT60%
    250 W – 300 Ω
  • Max output power monopolar cut-coag CUT40%
    200 W – 300 Ω
  • Max output power monopolar cut ENHANCED
    250 W – 500 Ω
  • Max output power monopolar cut-coag BLEND
    250 W – 300 Ω
  • Max output power monopolar coag SPEEDY
    120 W – 500 Ω
  • Max output power monopolar coag DEEP
    120 W – 200 Ω
  • Max output power monopolar coag SPRAY
    100 W – 2000 Ω
  • Max output power monopolar coag SPRAY ARGON
    100 W – 2000 Ω
  • Max output power of bipolar CUT
    120 W – 50 Ω
  • Max output power bipolar cut-coag CUT80%
    120 W – 50 Ω
  • Max output power bipolar cut-coag CUT60%
    120 W – 50 Ω
  • Max output power bipolar cut-coag CUT40%
    100 W – 50 Ω
  • Max output power bipolar cut-coag BLEND
    120 W – 150 Ω
  • Max output power bipolar coag COAG
    120 W – 50 Ω
  • Vessel sealing
    200 W – 50 Ω
  • Working frequency Monopolar / Bipolar
    425 kHz / 525 kHz
  • Patient circuit
    F
  • Selectable input voltage
    115 – 230 Vac
  • Mains frequency
    50 – 60 Hz
  • Electrical input power
    1000 VA
  • Size WxHxD
    470x150x400 mm
  • Weight
    17,5 Kgs

CONTROLS

  • Patient/Plate circuit monitoring
  • Output power monitoring
  • Self-check control
  • H.F. Leakage currents control
  • Compensation for mains fluctuation

SAFETY

  • EN60601-1
  • EN60601-1-2
  • EN60601-2-2
  • Level of protection provided by housing: IP21

Reviews

There are no reviews yet.

Be the first to review “SURTRON 400 HP”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsSURTRON 400 HP removeReusable Electrosurgical Pencil removeDisposable ECG Monitoring Electrode removeOBS-100C LCD Version Dual cold RF Electrosurgical Unit removeBipolar Irrigated Coagulator removeDisposable Skin Stapler remove
NameSURTRON 400 HP removeReusable Electrosurgical Pencil removeDisposable ECG Monitoring Electrode removeOBS-100C LCD Version Dual cold RF Electrosurgical Unit removeBipolar Irrigated Coagulator removeDisposable Skin Stapler remove
Image
SKUSF1033560130165-11SF1033560130165-24SF1033560130165-1SF1033560130165-12SF1033560130165-21
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad SURTRON 400 HP can be used to simultaneously perform monopolar and bipolar surgery in application fields that require high precision and reliability.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Disposable ECG Electrodes consist of snap set, conductive gel, backing material with medical adhesive, and release film. OBS Disposable ECG Electrodes model 301 are Non-woven, Micropore fabric backing Electrodes . These electrodes are applied by or on the order of a physician on a patient’s skin, the model 301 is fit for the general electrocardiographic application of both adults and children.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Unique dual radio frequency design. Combines 4Mhz and 1.7Mhz into one generator. Realizes the best operation result effectively. Suitable for  Plastic, Dermatology, ENT, Ophthalmology, Dentistry, Podiatry and Spinal surgery
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Sterile Disposable Skin Stapler is a disposable equipment that applies to skin sutures during general surgical operation, Cardiothoracic Surgery, plastic surgery, neurosurgery operation, gynecologic surgery, burn surgery, emergency operation, and field rescue. It can be used in operating room, delivery room, emergency department, outpatient surgery, and clinics.
Content
Features
DOUBLE ACTIVITY ‘OPERATION • Two output channels for monopolar cutting • Two independent settings and output channels for monopolar coagulation are more frequent CONTROLLED CUTTING PROCEDURES • cutting currents for eschar-free incision • Cutting current with selectable coagulating property for bleeding-controlled dissection • Low capacitive coupling by current endoscopic procedures, Slow BLEND DOUBLE PROCEDURES SUBSIDIARIES COAGULATION • SPEEDY Coag Coag DEEP ** * and two operators • SPRAY COAG is achievable with a handpiece or pedal WIDE BIPOLAR FEATURES • Bipolar cutting with bleeding control • Cutting current Slow BLEND • Start and stop automatically activate separately TOTAL SAFETY FOR PATIENT AND SURGEON • Acceptability of contact impedance between the patient’s body and the neutral plate is constantly verified by the electronic control Skin Plate Electronic Control called SPEC • Continuous monitoring of leakage current • Change in automatically compensated mains voltage before starting the RF power output CUSTOM PROCEDURES • Independent choice of coagulation currents and power levels of each of the two operators • Ten configurable personal procedures and immediately recallable CONDUCT OF EXTENSIONS AND SIGNAL CONNECTION • outputs for connections driven by argon plasma units and smoke aspirator AUTOMATIC SELF-DIAGNOSIS WITH SURTRON 400 HP • Automatic diagnostic control of the actual complete electronic drive functionality and accessories, connected and coded report of found failures * Coag SPEEDY is also called Fulgurate or Forced ** Coag DEEP is also called Pin Point, Desicate, or Soft  
Technical Data
  • Max output power monopolar pure CUT 400 W – 300 Ω
  • Max output power monopolar cut-coag CUT80% 300 W – 300 Ω
  • Max output power monopolar cut-coag CUT60% 250 W – 300 Ω
  • Max output power monopolar cut-coag CUT40% 200 W – 300 Ω
  • Max output power monopolar cut ENHANCED 250 W – 500 Ω
  • Max output power monopolar cut-coag BLEND 250 W – 300 Ω
  • Max output power monopolar coag SPEEDY 120 W – 500 Ω
  • Max output power monopolar coag DEEP 120 W – 200 Ω
  • Max output power monopolar coag SPRAY 100 W – 2000 Ω
  • Max output power monopolar coag SPRAY ARGON 100 W – 2000 Ω
  • Max output power of bipolar CUT 120 W – 50 Ω
  • Max output power bipolar cut-coag CUT80% 120 W – 50 Ω
  • Max output power bipolar cut-coag CUT60% 120 W – 50 Ω
  • Max output power bipolar cut-coag CUT40% 100 W – 50 Ω
  • Max output power bipolar cut-coag BLEND 120 W – 150 Ω
  • Max output power bipolar coag COAG 120 W – 50 Ω
  • Vessel sealing 200 W – 50 Ω
  • Working frequency Monopolar / Bipolar 425 kHz / 525 kHz
  • Patient circuit F
  • Selectable input voltage 115 – 230 Vac
  • Mains frequency 50 – 60 Hz
  • Electrical input power 1000 VA
  • Size WxHxD 470x150x400 mm
  • Weight 17,5 Kgs
CONTROLS
  • Patient/Plate circuit monitoring
  • Output power monitoring
  • Self-check control
  • H.F. Leakage currents control
  • Compensation for mains fluctuation
SAFETY
  • EN60601-1
  • EN60601-1-2
  • EN60601-2-2
  • Level of protection provided by housing: IP21
Features
  • High-quality tried-and-tested materials guarantee a long service life for OBS reusable electrosurgical pencils.
  • Material is durable for high temperature and high press disinfection for more than 30 times.
  • Cost compared to disposable instruments
  • The initial cost of the reusable electrosurgical pencil is easily recouped after only a fraction of the expected number of uses and compares favorably to the cost of disposable pencils.
Indications for Use:

Disposable ECG Electrodes are pre-gelled, non-sterile, single use disposable electrocardiographic electrodes which are intended for use as an accessory to ECG equipment for ECG monitoring , diagnostic procedures and can used for stress test & holter.

Instruction for Use:

1. Clean the skin area where the electrode will stick on. Make sure the skin area for sticking is intact (uninjured). 2. Connect the leadwire with the electrode. Make sure it is fastened and in good contact. 3. Tear off the release film from the bottom (the part away from metal stud) of electrode. 4. Press lightly when stick the electrodes to the skin and make sure the conductive gel and adhesive backing stick on the skin tightly. Caution

  • Don’t peel the release film from the metal stud of the electrode. It may break the structure and affect the function of electrodes.
  • ECG electrodes should only be used by or in consultation with a healthcare provider familiar with their proper placement and use.
  • ECG electrodes may damage the skin if removed carelessly.
  • ECG electrodes should be applied only to intact, clean skin (e.g., not over open wounds, lesions, or infected, or inflamed areas).
  • Do not reuse this device. It may cause infection and affect the performance of the reuse of this device.
Features
  • Clinic result proves that higher frequency can get less tissue resists nee. 4Mhz frequency can reduces heat injury a ind carbonizing to tissue at maximum. It realizes low temperature cutting.
  • The antenna pad is unnecessary for skin touch, no current goes through the body, and no possibility of burning
  • No pressure cutting and the pencil is operated easily and it's full of flexibility.
  • No carbonation, less bleeding, and no adhesions.
  • Less pain, scarring, and fast healing after operation.
Technical Parameters
Image
Product Details
OUTPUT MODE 
  • CUT - For micro-smooth cutting
  • BLEND - For cutting with coagulation
  • HEMO - For pure Hemostasis-Coagulation to control most forms of bleeding
  • FULGURATION - For desiccation or fulgurate spark-gap
  • BIPOLAR - For precise coagulation utilizing bipolar energy
INTENDED USE
  • Cutting: snoring, submucosal palatal shrinkage, traditional uvulopalatoplasty (RAUP), myringotomy with effective hemorrhage control, epistaxis treatment, turbinate shrinkage, skin incisions, biopsy, cysts, abscesses, tumors, cosmetic repairs, development of skin flaps, skin tags and blepharoplasty.
  • Blended (cutting and coagulation): snoring, submucosal palatal shrinkage, traditional uvulopalatoplasty (RAUP), myringotomy with effective hemorrhage control, epistaxis treatment, turbinate shrinkage, skin tags, papilloma keloids, keratosis, verrucae. basal cell carcinoma, nevi, fistulas, epithelioma, cosmetic repairs, cysts, abscesses, and development of skin flaps.
  • Hemostasis: control of bleeding, epilation, telangiectasia.
  • Fulguration: basal cell carcinoma, papilloma, cyst destruction, tumors, verrucae, hemostasis.
  • Bipolar: pinpoint precise coagulation, pinpoint hemostasis in any field (wet or dry), snoring, submucosal palatal shrinkage, traditional uvulopalatoplasty (RAUP), myringotomy with effective hemorrhage control, epistaxis treatment and turbinate shrinkage.
Transportation Data :
  • WxHxD:34(L)'23.5(W)*10.6(H) 49(L)*35.5(W)'31(H)cn Weight:8.2kg(NetWeight);12. cm(Generator) i(outer carton) 1kg(Gross Weight)
  • Standard Matching Accessories
  • Instruction for Use: 1pc
  • Power Cord: 1pc
  • Dual Pedal Switch: 1pc
  • Disposable ESU Pencil: 2 pes
  • Reusable Antenna Pad with cable: 1 set
  • Reusable Bipolar Forceps with Cable: 1 set
  • Reusable ESU pencil: 1 pc
  • Reusable Fine Electrode tips (Needle, curved, Needle .Ball): 7pcs
  • Disposable leep Electrode tips: 5pcs
Features

1. LED light positioned between the electrodes enhances the vision during surgery.

2. Massive area hemostasis can be performed in a short time in order to reduce intraoperative blood loss 3. Saline line and dripping device are equipped in an attempt to contain the heat on the treated tissue and avoid thermal tissue damage
Indications for Use
  • Ensure that both electrodes are in contact with the tissue to be treated. Activation and saline flow occur simultaneously.
  • Ensure that saline is flowing at the time of activation
  • These devices should never be used when:
  • There is visible evidence of damage to the exterior of the device such as cracked or damaged plastic or connector damage.
  • These devices fail the inspection described herein.
  • In the presence of flammable gases, flammable prep solutions or drapes. Oxidizing. Gases such as Nitrous Oxide (N2O), or in oxygen-riched environments.
  • Do not use monopolar electrosurgery on small appendages, as in circumcision or finger surgery.
Features
  • Concise and reasonable design, which is easy and convenient to operate.
  • Safe and efficient for surgery, and the needle could be withdrawn fluently and accurately.
  • Smooth and beautiful suture, small and micro healing scar.
  • There's good compatibility with tissues and less inflammatory response.
  • It's easy and convenient to take out the stitches, which will promote wound healing.
  • Sterile Disposable Skin Stapler reduces the patient's pain and improves operation efficiency.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare