Genoray ZEN-7000 Surgical Mobile C-Arm
$0.00
Shipped From Abroad
Fluoroscopy Powerful, Light and Versatile Performance with the 9″ high-resolution image intensifier and million pixel (1K x 1K) high-definition camera, the Zen-7000 supports clear images without distortion to provide the best diagnostic imaging environment possible.
Delivery & Availability:
Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Fluoroscopy Powerful, Light and Versatile Performance with the 9″ high-resolution image intensifier and million pixel (1K x 1K) high-definition camera, the Zen-7000 supports clear images without distortion to provide the best diagnostic imaging environment possible.
Exceptional Image Quality
- 9″ or 12” image intensifier
- 1K x 1K High resolution CCD Camera
- Wide FOV (Field-of-View)
- Low Dose, Low Noise
- High-Definition
- High Contrast
- Rotating Anode Tube
X-Ray Dose Management
- Low Dose Mode
- Auto / Virtual Collimator
Iris Collimator
Compact & Intelligent Design
- Lightweight Architecture
- Intelligent operation
- Compact, Hybrid Body
- 7″ Touch Screen LCD Monitor
19-inch LCD Two Monitor
Powerful Software
- Image Management
- DICOM 3.0
- Database Management
- Approved Format
Air Cooling
- High Performance
Protection from Overheating and Damage
Click Here To Download Catalogue
Review(1)
Quick Comparison
| Genoray ZEN-7000 Surgical Mobile C-Arm remove | Biopsy Needle remove | Operating Light Four (4) Halogen bulbs remove | Instrument Tray remove | Agary I.V. Cannula remove | Keewell FT-2800 Blood & Infusion Warmer remove | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Name | Genoray ZEN-7000 Surgical Mobile C-Arm remove | Biopsy Needle remove | Operating Light Four (4) Halogen bulbs remove | Instrument Tray remove | Agary I.V. Cannula remove | Keewell FT-2800 Blood & Infusion Warmer remove | ||||||||||||
| Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||
| SKU | SF1033560088 | SF1033560084-133 | SF1033560084-170 | SF1033560084-199 | SF1033560084-221 | SF1033560075 | ||||||||||||
| Rating | ||||||||||||||||||
| Price |
|
|
| $6.90 | $7.10 | $1,238.00 | ||||||||||||
| Stock | ||||||||||||||||||
| Availability | ||||||||||||||||||
| Add to cart | ||||||||||||||||||
| Description | Shipped From Abroad
Fluoroscopy Powerful, Light and Versatile Performance with the 9″ high-resolution image intensifier and million pixel (1K x 1K) high-definition camera, the Zen-7000 supports clear images without distortion to provide the best diagnostic imaging environment possible.
Delivery & Availability:
Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock
| In stock
| In stock
| In stock
I.V Cannula with wings & injection port 24G/19mm, 0.70mm/20ml/min Injection port with unidirectional valve for facilitating extra medication and preventing back flow. Specially engineered recessed plug with protective ring to avoid risk of contamination. Angle & grooved wings for easy cannulation and to prevent rolling of cannula over patient body. Colour coded cap for easy identification of guage size.
| Shipped From Abroad
Technology of control:
Microprocessor integrated with temperature sensors provides high precise control
Safety system:
Permanent running self-tests, 24 hours continuous operating
Double independent over-heating protections and automatic cut off
Visual and acoustic alarm for high temperature / low temperature/sensor fault
Dual channels:
Each channel can work independently with own temp. setting and temp control
Two channels can be combined to enlarge the warming capacity
Heating up to the patient: IV tube is completely wrapped in, no heat loss
Delivery & Availability:
Typically 7-14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| ||||||||||||
| Content | Fluoroscopy Powerful, Light and Versatile Performance with the 9″ high-resolution image intensifier and million pixel (1K x 1K) high-definition camera, the Zen-7000 supports clear images without distortion to provide the best diagnostic imaging environment possible. Exceptional Image Quality
Click Here To Download Catalogue | Bone marrow biopsy needle core can be used to biopsy various organ and be equipped with various needles for a variety of soft tissue biopsies, such as liver, kidney, mammary glands, spleen, lungs or lymph nodes. Small and light weight designing, for easy handling.Two available puncture depths, 10mm(location"1") and 18mm(location"2"), provide convenient clinical choice.The external needle could be took down, then equipped with the core needle portable for convenient orientation and multiple sampling.
|
|
| I.V Cannula with wings & injection port 24G/19mm, 0.70mm/20ml/min Injection port with unidirectional valve for facilitating extra medication and preventing back flow. Specially engineered recessed plug with protective ring to avoid risk of contamination. Angle & grooved wings for easy cannulation and to prevent rolling of cannula over patient body. Colour coded cap for easy identification of guage size. | Features:Technology of control: Microprocessor integrated with temperature sensors provides high precise controlSafety system:Permanent running self-tests, 24 hours continuous operating Double independent over-heating protections and automatic cut off Visual and acoustic alarm for high temperature / low temperature/sensor faultDual channels:Each channel can work independently with own temp. setting and temp control Two channels can be combined to enlarge the warming capacity Heating up to the patient: IV tube is completely wrapped in, no heat lossUser friendly interface:Big LED screen showing set temp., actual temp., heating time and fault situation Easy and quick to set up, ready to use within minutes. Open system: Accepts standard IV tube, no special disposables needed The most economical warming solution without extra consumable costs TECHNICAL SPECIFICATIONS Model: FT2800 Temperature setting: 33 - 41˚C Power supply: a.c.100~240V/50~60Hz Power consumption: Max. 180VA Type of protection against electric shock: Class I Degree of protection against electric shock: BF Applied part; Defibrillation-protected Degree of protection against ingress of liquids: IPX2 Temperature accuracy: ±1.0˚C Overheat protection: 42˚C /43˚C Low temperature alarm: 32˚C Warming up time: From 20˚C to 36˚C approx.2 min. Operating mode: Continuous Dimension (W*D*H): 200×130×250mm Net Weight: 2.3kg Warming profile: - length 1400mm - compatible IV tube 3.5-5.0mm O.D.Click Here To Download Catalogue | ||||||||||||
| Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||
| Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||
| Additional information |














muneer alkojak
good morning
i need soft ware for this device