New

Anaesthesia Machine Model 50

$0.00

Shipped From Abroad

The Anesthesia Workstation Model 30 is an advanced medical device featuring precise ventilation control, integrated vaporizers, safety alarms, and a user-friendly interface for efficient anesthesia delivery in surgical environments.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: Medovo

Description

Features
  • Contains Output interface for Anesthesia information management system.
  • Complete with backup battery for working more than 120 minutes.
  • Built-in 10.4” color anesthesia ventilator

  • Traditional CO₂ absorber (autoclavable, Patent)

  • Dual high-end precise vaporizers (Volume > 280ml)

  • Three gas sources system (O₂/N₂O/Air)

  • Continuous FiO₂ monitoring & bain circuit interface

  • Electronic tidal volume (Innovation)

  • Battery backup for all systems over 60 mins

  • Optional: Backup Yoke system (O₂, N₂O)

  • Optional: Anesthesia gas scavenging system

  • Optional: Anesthesia gas modular patient monitor

  • Structure made of ABS

  • Large pressure gauges for easy reading

  • CO₂ absorber with easy changeover system

  • Optional: Yoke system for backup 1×O₂, 1×N₂O A-Type cylinder

Safety Features
  • Gases interlocking system with hypoxy guard

  • Oxygen exhaust alarm

  • Blow-off valve in top circuit

 

Technical Specification

Anaesthesia main unit

  • High resolution 10.4″ color TFT LCD screen

  • Dual-end pressure flow sensor, the unit can monitor Tidal Volume, Respiratory frequency, airway pressure, pressure-time wave, flow-time wave (two-way), High Pressure limitation, Low Pressure limitation, Apnea, Oxygen concentration under both two operating modes (Auto, Manual)

  • Respiration loop function

  • Close, semi-close, semi-open

  • Application: Adult, Pediatric

  • Low gas alarming: It gives an alarm if it lasts more than 7 seconds.

  • High pressure Limitation: Whenever airway pressure exceeds the pre-set High pressure, the ventilator offers automatic protection to ensure patient safety.

  • Low pressure protection: Once O₂ pressure is less than 0.1MPa, N₂O gas supply stops automatically.

  • Power failure alarming, power extendable function

  • O₂ flush: 25 ~ 75L/min

  • Gas Pressure:

    • O₂: 0.3 ~ 0.5MPa

    • N₂O: 0.3 ~ 0.5MPa

    • AIR: 0.3 ~ 0.5MPa

  • Power: 220V±10%, 50Hz±1%; Backup USP Battery.

  • Optional: Yoke system for backup O₂, N₂O cylinders

Flow meter

  • O₂, N₂O, AIR – six tubes (0.05 ~ 1 L/min, 1 ~ 10L/min)

  • O₂/N₂O inter-lock system, to keep O₂ concentration no less than 25%

Anaesthesia Ventilator

  • Adult, Pediatric bellows 1 set each

  • Pneumatic-driven electric control

  • Monitor Parameters: Tidal volume, Respiratory frequency, I:E rate, M.V., FiO₂, Apnea, Peak airway pressure, airway pressure waves (P-T, F-T) etc.

  • Working mode: Manual, Auto (IPPV, SIMV, A/C, SIGH, PCV, PSV, Demo.)

  • Tidal volume: 50 ~ 1500 mL

  • Respiratory frequency: 4 ~ 99 bpm

  • I:E Ratio: 1.0:5 ~ 1:8 (adjustable)

  • Synchronizer trigger Pressure: -2 ~ 0 kPa

  • High pressure limitation: 2 ~ 6 kPa

  • Low pressure limitation: 0 ~ 2 kPa

Respiratory Circuit

  • Consolidated compact CO₂ absorber (autoclavable).

Vaporizer

  • High-end precise vaporizer (Halothane, Isoflurane, Sevoflurane)

  • Halothane/Isoflurane adjustable range: 0.5 ~ 5% VOL

  • Sevoflurane adjustable range: 0.5 ~ 8% VOL

  • Automatic compensation function – flow, pressure, temperature

  • Self-lock function & inter-lock function

  • Volume: >280 ml

Reviews

There are no reviews yet.

Be the first to review “Anaesthesia Machine Model 50”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsAnaesthesia Machine Model 50 removeHersill Genesis Anaesthetic Machine removeRender SD-M2000A(P) Transport/Portable Anesthetic Machine removeSpinal Epidural Pack removeElastomeric Pump (Disposable Infusion Pump) with PCA removeRender SD-M2000B Anesthetic Machine remove
NameAnaesthesia Machine Model 50 removeHersill Genesis Anaesthetic Machine removeRender SD-M2000A(P) Transport/Portable Anesthetic Machine removeSpinal Epidural Pack removeElastomeric Pump (Disposable Infusion Pump) with PCA removeRender SD-M2000B Anesthetic Machine remove
ImageHersill Genesis Anaesthetic Machine
SKUSF1033560450-1SF1033560011-12SF1033560084-25SF1033560084-18SF1033560011-10
Rating
Price

$0.00

$0.00

$1,320.00

$0.00

$0.00

$4,840.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad The Anesthesia Workstation Model 30 is an advanced medical device featuring precise ventilation control, integrated vaporizers, safety alarms, and a user-friendly interface for efficient anesthesia delivery in surgical environments.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation. Application Field: Neonates, Pediatrics & Adults Ventilation Modes: Volume controlled (VC), Pressure controlled (PC), Adaptive Pressure with Volume Guaranteed (APVG) & Pressure Support Ventilation (PSV) Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad
  • High quality & Durability Design
  • Easy operation & easy maintenance
  • Compact construction
  • Beautiful & delicate
  • Space saving for operation room.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock It is for performing spinal/epidural or combined spinal/epidural or never-block loco-regional anaesthesia on patinet in clinical surgery.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock This product make the tension of silicon capsule as the driving force to control the flow by micro porous tube, it was pre-selected by doctor base on patients'situation, and then and then handed over to the patients ' self- management “to relieve or ease the pain

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad
  • Contains Output interface for Anesthesia information management system.
  • Complete with backup battery for working more than 30 minutes.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features
  • Contains Output interface for Anesthesia information management system.
  • Complete with backup battery for working more than 120 minutes.
  • Built-in 10.4” color anesthesia ventilator

  • Traditional CO₂ absorber (autoclavable, Patent)

  • Dual high-end precise vaporizers (Volume > 280ml)

  • Three gas sources system (O₂/N₂O/Air)

  • Continuous FiO₂ monitoring & bain circuit interface

  • Electronic tidal volume (Innovation)

  • Battery backup for all systems over 60 mins

  • Optional: Backup Yoke system (O₂, N₂O)

  • Optional: Anesthesia gas scavenging system

  • Optional: Anesthesia gas modular patient monitor

  • Structure made of ABS

  • Large pressure gauges for easy reading

  • CO₂ absorber with easy changeover system

  • Optional: Yoke system for backup 1×O₂, 1×N₂O A-Type cylinder

Safety Features
  • Gases interlocking system with hypoxy guard

  • Oxygen exhaust alarm

  • Blow-off valve in top circuit

 
Technical Specification

Anaesthesia main unit

  • High resolution 10.4" color TFT LCD screen

  • Dual-end pressure flow sensor, the unit can monitor Tidal Volume, Respiratory frequency, airway pressure, pressure-time wave, flow-time wave (two-way), High Pressure limitation, Low Pressure limitation, Apnea, Oxygen concentration under both two operating modes (Auto, Manual)

  • Respiration loop function

  • Close, semi-close, semi-open

  • Application: Adult, Pediatric

  • Low gas alarming: It gives an alarm if it lasts more than 7 seconds.

  • High pressure Limitation: Whenever airway pressure exceeds the pre-set High pressure, the ventilator offers automatic protection to ensure patient safety.

  • Low pressure protection: Once O₂ pressure is less than 0.1MPa, N₂O gas supply stops automatically.

  • Power failure alarming, power extendable function

  • O₂ flush: 25 ~ 75L/min

  • Gas Pressure:

    • O₂: 0.3 ~ 0.5MPa

    • N₂O: 0.3 ~ 0.5MPa

    • AIR: 0.3 ~ 0.5MPa

  • Power: 220V±10%, 50Hz±1%; Backup USP Battery.

  • Optional: Yoke system for backup O₂, N₂O cylinders

Flow meter

  • O₂, N₂O, AIR – six tubes (0.05 ~ 1 L/min, 1 ~ 10L/min)

  • O₂/N₂O inter-lock system, to keep O₂ concentration no less than 25%

Anaesthesia Ventilator

  • Adult, Pediatric bellows 1 set each

  • Pneumatic-driven electric control

  • Monitor Parameters: Tidal volume, Respiratory frequency, I:E rate, M.V., FiO₂, Apnea, Peak airway pressure, airway pressure waves (P-T, F-T) etc.

  • Working mode: Manual, Auto (IPPV, SIMV, A/C, SIGH, PCV, PSV, Demo.)

  • Tidal volume: 50 ~ 1500 mL

  • Respiratory frequency: 4 ~ 99 bpm

  • I:E Ratio: 1.0:5 ~ 1:8 (adjustable)

  • Synchronizer trigger Pressure: -2 ~ 0 kPa

  • High pressure limitation: 2 ~ 6 kPa

  • Low pressure limitation: 0 ~ 2 kPa

Respiratory Circuit

  • Consolidated compact CO₂ absorber (autoclavable).

Vaporizer

  • High-end precise vaporizer (Halothane, Isoflurane, Sevoflurane)

  • Halothane/Isoflurane adjustable range: 0.5 ~ 5% VOL

  • Sevoflurane adjustable range: 0.5 ~ 8% VOL

  • Automatic compensation function – flow, pressure, temperature

  • Self-lock function & inter-lock function

  • Volume: >280 ml

The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation, accuracy and performance, cost saving, design and ergonomics, safety and versatility.   TECHNICAL SPECIFICATION OPERATING DATA
  • Weight - 105 kg
  • Dimensions - 92 cm Wide x 68 cm Deep x 139 cm High (93 cm to the table surface)
  • Packaging Dimensions - 105 cm Wide x 75 cm Deep x 160 cm High
  • Operating voltage supply - 110 to 240 V~, 47 to 63 Hz (12 to 6 A)
  • Power input - 120 W typically (max. 1.2 kW with auxiliary outlets used)
  • Battery autonomy - 90 min typically
  • Auxiliary power outlets - 4, with automatic protection
  • O2, N2O and Air supply - 2.7 to 6.9 bar (39.1 to 100 psi)
  • Screen - TFT 18.5" (47 cm) projected capacitive touchscreen
  • Protection class - Class I, gas analyser type BF defibrillation proof
  • Classification - Class II b
  • Storage - One front drawer with self-brake system and two back cabinets with door
  • Lighting - LED bar below the screen controlled from the touchscreen
  • Auxiliary integrated systems - Auxiliary 02 flow meter (0-15 L/min), Auxiliary 02 suppy valve (NF standard) and Suction device
  • Communication ports - 1 x RS-232, 2 x USB, 1 x LAN Ethernet
Fresh Gases (02, N20 and Air, electronically controlled)
  • Fresh gas flow - 0 and 0.1 to 18 L/min 02/N20/Air
  • Accuracy - 0.1 to 0.5 L/min = ±0.05 L/min; 0.5 to 18 L/min = ±10 %
  • 02 concentration - 21 to 100% vol. with Air, 25 to 100% with N20 (minimum 200 ml/min 02)
  • 02 Safety fresh gas (backup) - 0-0.2-0.4-0.7-1-1.5- 2- 3- 4- 6- 8-10-12-15 L/min 02
  • 02 flush (+02) - 40 L/min standard (adjustable 25 - 75 L/min upon requirement)
Breathing System (CABS)
  • Autoclavable - 134 °C
  • Weight of breathing system - 9.8 kg
  • C02 absorber volume - 1.5 L
  • Leakage - < 150 mL/min (at 30 hPa)
  • Pressure limiting valve APL - 0 to 70 hPa
  • Pressure relief valve - 125 hPa
  • Vacuum safety valve - 0.3 hPa
  • resistance at 60L/min - 5.80 hPa
  • resistance at 60L/min - 2.90 hPa
  • resistance at 30L/min - 3.55 hPa
  • resistance at 30L/min - 0.89 hPa
  • Internal Compliance at 30 hPa - 15 mL
  VENTILATOR Operation / Ventilation Modes Volume controlled (VC) modes:
  • Volume Controlled Ventilation (VCV)
  • VC Synchronized Intermittent Mandatory Ventilation (VC-SIMV)
  • VC-SIMV with Pressure Support (VC-SIMV-PS) *
Pressure controlled (PC) modes:
  • Pressure Controlled Ventilation (PCV)
  • PC Synchronized Intermittent Mandatory (PC-SIMV)
  • PC-SIMV with Pressure Support (PC-SIMV-PS) *
Adaptive Pressure with Volume Guaranteed (APVG) modes (other trade names: Autoflow,PCVR, PRVC, AVAPS, VC+)
  • Adaptive Pressure with Volume Guaranteed (APVG) *
  • APVG Synchronized Intermittent Mandatory (APVG-SIMV) *
  • APVG -SIMV with Pressure Support (APVG-SIMV-PS) *
Pressure Support Ventilation (PSV) *
  • (other trade names: PS, ASB, SPS, IPS)
  Non-mechanical Operation / Ventilation Modes
  • Manual ventilation through the CABS system (Auto/Manual software controlled)
  • Spontaneous ventilation either through the bellows (auto mode) or through the bag
  • (manual mode) Manual ventilation through the external fresh gas outlet for non-rebreathing systems (Bain, Mapleson, ...)
Application field: Neonates, Pediatrics & Adults
  • Tidal volume - 5 to 1500 mL
  • Inspiratory pressure - 0 to 68 hPa
  • Ventilation frequency ­- 3 to 120/min
  • Inspiratory time - 0.05 to 16.6s
  • l:E ratio - 5:1 to 1:8
  • Inspiratory pause - 0 to 60%
  • Inspiratory flow - max. 150 L/min
  • PEEP - 0 to 30 hPa
  • Flow trigger - 0.2 to 15 L/min
  • Pressure support - 5 to 50 hPa
  • Ramp time - 0.1 to 2 s
  • Maximum pressure - 0 to 68 hPa
  MONITORING
  • 5" (47 cm) projected capacitive touchscreen, supported on a 360° rotating and 2 axis tilting arm.
  • Measurements displayed: Peak pressure; Plateau pressure; Mean pressure; Expiratory minute ventilation; Expiratory tidal volume; Inspiratory tidal volume; Expiratory volumeter; Breathing rate; Compliance and Resistance (in VC modes); Patient info (age, weight, MAC, Class ASA); Connected sensors; Battery status; Power supply status; Gases supply pressures for 02, N20 and Air; Inspiratory and expiratory concentration of 02, N20, C02 and Anaesthetic gas*
  • Parametres charted as curves (up to 3 simultaneously): Airway pressure; Expiratory flow; Inspiratory flow; Volume; Fresh gases (Rotstyle); Concentration of 02, N20, C02 and Anaesthetic gas*; Trends: Minute volume, MAC and gases (02, N20, C02 and Anaesthetic gas).
  • Display for the performance of the hospital Anaesthetic Gas Scavenging System (AGSS).
  • Configurable interface: bright/dark, multi-language.
  • Loops (up to 2 simultaneously): Volume-Pressure, Flow-Volume, Pressure-Flow, C02-Volume.
  • Fresh gas virtual rotameters for 02, N20, Air. * C02, N20 and Anaesthetic gas monitoring with the accessory multigas analyzer main-stream or side-stream; 02 real-time monitoring via paramagnetic
 
Click Here To Download Catalogue
  • High quality & Durability Design
  • Easy operation & easy maintenance
  • Compact construction
  • Beautiful & delicate
  • Space saving for operation room.
 
Click Here To download Catalogue
   
 
It is for performing spinal/epidural or combined spinal/epidural or never-block loco-regional anaesthesia on patinet in clinical surgery. Component:
  • Epidural needle 16G,
  • Epidural catheter,
  • Epidural filter 0.2 um,
  • Catheter connector,
  • LOR syringe
This product make the tension of silicon capsule as the driving force to control the flow by micro porous tube, it was pre-selected by doctor base on patients'situation, and then and then handed over to the patients ' self- management “to relieve or ease the pain Product Components: one-way valve medicated device, elastic liquid storage device, liquid medicine filter, current limiting device, automatic liquid feeding device ( CBI & PCA ), pipe and the external connector; Product Features: 1. The continued to liquid (CBI) make the drug-stored sac mechanical stretch as a driving force, limited the flow through the micro porous tube to the patient safely, effectively, slightly, continuous uniform injection of liquid to analgesic effect; extrusion pump body does not affect the liquid normal velocity; liquid filtering device which can control the particles enter the body better; 2. Continued to liquid + self control to liquid ( CBI+PCA ) make the drug-stored sac mechanical stretch as a driving force, limited the flow through the micro porous tube to the patient safely, effectively, slightly, continuous uniform injection of liquid to analgesic effect; Automatic medicated function is the patients can medicate according to pain independently. Extrusion pump body does not affect the liquid normal velocity; liquid filtering device which can control the particles enter the body better; How to use: 1. Get analgesia pump out from sterile packaging, removing the cap of medicine inlet and outlet; pour the analgesic liquid in the liquid storage device, draw out the air from the liquid storage. 2. Finish medicating, waiting for the liquid outflow from the medicine outlet; please clamp tightly to stop flowing for preparation. 3. Control keys (PCA key) is a function key to add the medicine base on continue to medicated by patients' self-controlled. So the patients can self-control the PCA key under the guidance of doctors, according to the needs while they are in treatment. At the same time, doctor should fill in PCA treatment card, so that they can analyze the condition from PCA additional times.
Features:
  • Contains Output interface for Anesthesia information management system.
  • Complete with backup battery for working more than 30 minutes.
  Technical Specifications:
Model: SD-M2000B
Brand: RENDER
Origin: Made In China
Category: Electronics & Electricity / Electronic Instrument / Electricity Meter & Instrument
Label: anesthesia machine , anesthesia ventilator , anesthesia machine
 
Click Here To Download Catalogue
 
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare