Description | Shipped From Abroad
The ED-8000C is a bi-directional wave automated external defibrillator with versatility designed to meet everyone's needs. It is suitable for use in the military, medical, home, and hospitality settings wherever an ADE device is required. It incorporates proven defibrillation technology that analyzes a person's heart rate during a cardiac arrest.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR).
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
- Total Volume: 60mL.
- Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
- Made of premium PP material, it is durable for usage.
- Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Aboard
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
- Microprocessor control.
- Digital display setting and actual temperature.
- Over temperature alarm, PID self-tuning.
- Digital display running timer.
- Stainless steel interior.
- Electricity leakage protection.
- With glass inner door, With hidden door locks.
- Mechanical overheat protection, cut off the heating sources.
- Automatic alarm after operation.
- Suitable for constant temperature tests.
- Suitable for bacteria cultivation, breeding, ferment.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
Content | Advantages of AED Defibrillator:
Whether you are a medical professional, you can quickly operate the instrument. When you need to fight for time in cardiac arrest, the AED's voice prompts can guide you through the pre-use preparations and quickly enter the defibrillation stage. And the high-resolution touchscreen makes it easy to view and respond to notifications or adjust settings.
The ED-8000C is a portable automated external defibrillator that connects to your cell phone to view and locate data if lost.
The ED-8000C wirelessly automates maintenance tasks and provides full visibility of your device. If the AED device is intended to be used with an older adult or needs to be used remotely, then you can monitor the device wirelessly. Easily share valuable data.
This AED device's small size and light weight make it easy to use and carry. And the whole machine is made of durable materials to ensure its long service life. It supports both rechargeable and battery power supply to ensure that it does not affect the life-saving performance.
Automated External Defibrillator Specifications:
Model |
ED-8000C |
Display |
Screen Type |
High-resolution display, TFT colour display |
Screen Size |
7 inches (17.7cm) diagonally |
Sweep Speed |
12.5/25/50mm/sec |
Information |
Heart Rate, Nibp, Spo2, Temp, Delivered Energy |
Resolution |
800x480 |
ECG |
Patient Connection |
3-lead ECG cable, or 5-lead ECG cable, paddles |
Lead Selection |
Displayed on monitor, paddles, I, II, III, AVR, AVL, AVF, V |
ECG Size |
2.5, 5, 10, 20, 30 mm/mV display on monitor |
Heart Rate |
20-350BPM |
Protection |
With stand 4000vAc/50Hz voltage in isolation and work against electrosurgical knife and defibrillation |
NIBP |
Working Mode |
Manual/Automatic |
Method |
Automatic oscillation |
Cuff Type |
Standard Adult; Optional Pediatric/Neonatal |
Temp. |
Measurement Range |
0~50℃ |
Resolution |
0.1℃ |
Pulse Oximetry (SpO2) |
Display |
SpO2 value, waveform, Pulse |
Range |
0~99%for adult, pediatric and neonatal patients |
Probe |
Standard adult finger clip |
Optional |
Pediatric Y-type clip and neonatal wrap |
Defibrillator |
Waveform |
Biphasic |
Defibrillator Type |
Manual External Synchronous/Asynchronous Defibrillation |
Charge Time |
Less than 10 seconds to 360 Joules |
Energy Display |
Monitor display indicates both selected and delivered energy. |
Charge Prompt Type |
Voice and visual prompts. |
Energy Selection |
Selectable at 0, 3, 5, 7, 10, 20, 30, 50, 100, 200, 300, 360 joules |
Standard Adult/ Pediatric Paddles |
Reusable external adult paddles (pediatric paddles integrated) |
Battery Description |
Standard Type |
Li-ion battery Li1104c 11.1Vdc 4000mAh X2 |
Standard Capacity |
Up to 10 hours ECG monitoring or 60 full-energy discharges. |
Low Battery Indicator |
Flashing low battery icon on display and Bat Indicator on the panel of
defi-monitor be on |
Recharge Rate |
80% in 3 hours.,100% in 5 hours |
Built-in Recorder |
Paper |
50mm thermal. |
Printing Method |
High-resolution, thermal print head |
Record date, time, sweep speed, waveform gain, heart rate, energy (joule) and ECG waveform |
Print Mode |
HR exceed limits alarm recording |
Auto timed recording |
Real-Time Recording |
Defibrillation discharge trigger recording |
Power Supply |
AC-DC dual-use |
Use the batteries AC100V~240V, 50/60 Hz |
Vehicle Voltage (Optional) |
DC 12V |
Main Unit |
Portable |
Maximum Power (W) |
600W |
Size(W×D×H)(mm) |
320x205x410 |
Shipping Size (W×D×H)(mm) |
580x480x490 |
N.W./G.W. (kg) |
8.3/18 |
AED
(Optional) |
Voice prompts and screen prompts |
Energy Programmable Sequence |
200, 300, 360 Joules; |
150,150, 200 Joules; |
50, 75, 100 Joules; |
30, 30, 50 Joules; |
Discharge Control |
Control on device front panel |
| The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr.
Features:
-
-
100µL sample drawn directly from primary EDTA tube
-
Fully automated, walk-away operation
-
-
Positive patient identification via internal barcode reader
-
Compatible with pediatric tube
Technical Specifications:
Principle of Measure: |
Photometrical |
Results: |
“Printed mm/hr, Range from 1-130 mm/hr” |
Sample Requirements: |
500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated. |
Tube Requirements: |
13 x 75 mm, pierceable capped tube |
Quality Control: |
Barcoded Seditrol® QC |
Barcode Reader: |
Internal |
Printer: |
Internal |
Interface Specifications: |
serial RS232 port for LIS connection |
Weight: |
14 kg |
Dimensions (H x W x D): |
36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in) |
Voltage: |
100-240VAC |
Frequency Range: |
50-60 Hz |
Power: |
160W |
Click Here To Download Catalogue |
- Total Volume: 60mL.
- Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
- Made of premium PP material, it is durable for usage.
- Some measurements can be used to not only use urine samples, it can also be used for other liquids.
| The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric
analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Feature
- Auto zero function: Manual blanking not required
- Dual wavelength measurement system:
- 2 wave lengths 455nm and 575nm
- Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
- LED Light source:
- LED does not require replacement as it lasts longer
- As compared to Lamp, LED are more suitable as there is no intensity fluctuations
- No warm up time required.
- Flexible unit selection:
- Two units either mg/dl or umol/L are selectable, ease of reporting
- Compact slot for Capillary:
- Accuracy of results are directly related to proper alignment of Capillary
- B-111 has the easiest mode to ensure precise values
- Data transfer:
- External device can be connected to instrument through RS232 por
- USB port
Technical Specification
- Light source - LED
- Wavelength - 455nm and 575nm
- Net weight - 1kg
- Measuring range - 0-30 mg/dl , 510 umol/L
- Display - 16×2 LCD module with backlight
- Auto calibration - Yes
- Sample type - Serum or plasma
- Sample volume - 40-80μL
- Test time - <5sec
- Units - mg/dl or umol/L
- Dimensions - 150 (W) × 115 (H) × 190 (D) mm
- Interface - RS232
- Reading cuvette - Heparinized micro capillary holder
- Storage temperature - 15-40°c
- Power supply - DC 9V(DC adapter)
- Power consumption - <2W
| Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use.
Size and packing of Medical Alcohol pad:
- Pad Size: Unfolded: 30 x 60 mm (other size can be request ).
- Folded: 30x30 mm, 30 x 35mm,can be 2ply or 4ply ( other size, ply can be request ).
- Aluminum Package: 60 x 50 mm , 50 x 50mm approximate ( other size can be request ).
- Packing: 100/200 pcs per inner box, 50/ 100 boxes per carton(packing can be request).
Use of Medical Alcohol pad:
- For cleaning prior to injection or to disinfect the hurted skin for family and medical treatment organization use.
- For preparation and immediate disinfection of skin, wound area orr Instrument and utensil.
Notice of Medical Alcohol pad:
- Not for eyes;
- keep out of reach of children;
- For external use only;
- please stop using if you feel allergic or amyctic
Materials - Non-Woven Fabric
Specification - CE&ISO13485
| Features:
- Microprocessor control.
- Digital display setting and actual temperature.
- Over temperature alarm, PID self-tuning.
- Digital display running timer.
- Stainless steel interior.
- Electricity leakage protection.
- With glass inner door, With hidden door locks.
- Mechanical overheat protection, cut off the heating sources.
- Automatic alarm after operation.
- Suitable for constant temperature tests.
- Suitable for bacteria cultivation, breeding, ferment.
Technical Specification:
Model: IB-9025A
Working size: 250x250x250mm/9.84x9.84x9.84inch
Power: 150W
Temperature range: Room temperature+5~65℃
Temperature resolution: 0.1℃
Temperature fluctuation: ±0.5℃
Timer: 0-9999min
Voltage: 110V 60Hz / 220V 50Hz
Dimension: 380x370x580mm/14.96x14.57x22.83inch
Size: 52cm*46cm*75cm / 20.5in*18.2in*29.6in
Gross Weight:42kg / 93lb
Net Weight: 23kg / 51lb