DynaMesh-CICAT

$0.00

Shipped From Abroad

DynaMesh-CICAT and DynaMesh-CICAT visible implants are intended for the surgical treatment of epigastric hernias, umbilical or incisional hernias, and the prevention of incisional hernias, and permanently bridge and reinforce the soft tissue of the abdominal wall in the area of the abdominal wall defect.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130161-5
Brands:: Dyna Mesh

Description

Anti-Slip Surface
The devices have an anti-slip surface that ensures stable positioning of the mesh with reduced fixation compared to other devices available on the market. [132PB, 133PB, 134]

Dynamometric Positioning
For the correct dynamometric positioning of the device, ensure that the green or black marking strips are in a cranio-caudal orientation.

High Effective Porosity
The devices have a high effective porosity, which is known to reduce inflammation and the risk of excessive scar formation. [103P, TR33, TR35]

 

The device must not be placed partially or completely intraperitoneally.

 

Specifications
Product DynaMesh®-CICAT (1)
DynaMesh®-CICAT visible (2)
Surgical Treatment Epigastric Hernias / Umbilical Hernias / Incisional Hernias
Prevention: Incisional Hernia
Surgical Approach Minimally Invasive / Open
Mesh Position Extraperitoneal
(onlay, sublay and/or preperitoneal)
Fixation Sutures / Tacks / Tissue Adhesives
Marking Strips Green (1) / Black (2)
Visible Technology graue_punkte (1) / gruene_punkte (2)
Materials – Polyvinylidene fluoride (PVDF) (CAS 24937-79-9) > 99% (w/w) (1) (2)
– Phthalocyanine green (CAS 1328-53-6) < 1% (w/w) (1)
– Triiron tetraoxide (CAS 1317-61-9) < 1% (w/w) (2)
Polymer (Monofilament)
PVDF
Biocompatibility
gruene_punkte[TR1]
Ageing Resistance
gruene_punkte[2A, 5VIT, 27A, 52VIT, 93A, 101]
Dynamometric Properties
gruene_punkte[TR38, 128P, 129]
Tear Propagation Resistance
gruene_punkte[TR31]
Anti-Slip Surface
gruene_punkte[132PB, 133PB, 134]
Effective Porosity gruene_punkteHigh effective porosity reduces inflammation and the risk of excessive scar formation. [103P, TR33, TR35]
Klinge’s Mesh Classification Class 1a [102P, TR33, TR35]
DynaMesh®-CICAT implants must be placed extraperitoneally in onlay, sublay and/or preperitoneal mesh position.
gruene_punkte Applies to all product sizes
gaue_punkte Does not apply
[#] Reference “#” (see “References”)
[TR#] Internal test report (see “internal test report references”)
Limitations “A” animal trial, “B” bench test, “VIT” in-vitro trial,
“P” published results based on the analysis of human mesh explants,
“PB” published results mainly based on bench tests

Click here to download Catalogue

Reviews

There are no reviews yet.

Be the first to review “DynaMesh-CICAT”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsDynaMesh-CICAT removeOxygen Regulator (Japan Technology) removePortable Stainless Steel Autoclave Sterilizer removeElectric Suction Machine removeOxygen Concentrator removeElastomeric Pump (Disposable Infusion Pump) with PCA remove
NameDynaMesh-CICAT removeOxygen Regulator (Japan Technology) removePortable Stainless Steel Autoclave Sterilizer removeElectric Suction Machine removeOxygen Concentrator removeElastomeric Pump (Disposable Infusion Pump) with PCA remove
Image
SKUSF1033560130161-5SF1033560084-48SF1033560084-4SF1033560084-16SF1033560084-31SF1033560084-18
Rating
Price

$0.00

$17.00

$216.00

$152.00

$350.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad DynaMesh-CICAT and DynaMesh-CICAT visible implants are intended for the surgical treatment of epigastric hernias, umbilical or incisional hernias, and the prevention of incisional hernias, and permanently bridge and reinforce the soft tissue of the abdominal wall in the area of the abdominal wall defect.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Full brass+chrome plated
  • Easy to read dual scal gauge with screw-on polycarbonate lens for durability.
  • Precision engineered pressure compensated design flowmeter for precise flow.
  • Flowmeter with easy to read tube and virtually unbreakable transparent polycarbonate outer cover for strength and 360 visibility.
  • Sintered metal inlet filter to trap impurities.
  • Reliable external safety relief valve.
  • Flush feature permits emergency oxygen to 40LPM.
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock
  • Can be set as required sterilization temperature, working tem. range:room tem.:+5~126 Degree.
  • Can ge set as required sterilization time of heat preservation, setting range:1~99min.
  • Having a low water to stop heating function.
  • This product uses the high quality stainless steel SUS304. Having to work under normal conditions adequate safety strength.
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Power consumption: 120W Maximum negative pressure: ≥0.09 MPa Pump rate: ≥20 L/min Noise: ≤60 dB Continuous Working Time: 0-30 min Bottle volume: 2500 ml, 2 pcs

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
Theory: Psa
Certification: CE, ISO13485
LCD Display: With LCD Display
Group: Adult
Oxygen Flow Rate: 0.5~8L/Min
Oxygen Density: >90%
 
  Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock This product make the tension of silicon capsule as the driving force to control the flow by micro porous tube, it was pre-selected by doctor base on patients'situation, and then and then handed over to the patients ' self- management “to relieve or ease the pain

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content

Anti-Slip Surface The devices have an anti-slip surface that ensures stable positioning of the mesh with reduced fixation compared to other devices available on the market. [132PB, 133PB, 134]

Dynamometric Positioning For the correct dynamometric positioning of the device, ensure that the green or black marking strips are in a cranio-caudal orientation.

High Effective Porosity The devices have a high effective porosity, which is known to reduce inflammation and the risk of excessive scar formation. [103P, TR33, TR35]
 

The device must not be placed partially or completely intraperitoneally.  
Specifications
Product DynaMesh®-CICAT (1) DynaMesh®-CICAT visible (2)
Surgical Treatment Epigastric Hernias / Umbilical Hernias / Incisional Hernias Prevention: Incisional Hernia
Surgical Approach Minimally Invasive / Open
Mesh Position Extraperitoneal (onlay, sublay and/or preperitoneal)
Fixation Sutures / Tacks / Tissue Adhesives
Marking Strips Green (1) / Black (2)
Visible Technology graue_punkte (1) / gruene_punkte (2)
Materials – Polyvinylidene fluoride (PVDF) (CAS 24937-79-9) > 99% (w/w) (1) (2) – Phthalocyanine green (CAS 1328-53-6) < 1% (w/w) (1) – Triiron tetraoxide (CAS 1317-61-9) < 1% (w/w) (2)
Polymer (Monofilament)
PVDF
Biocompatibility
gruene_punkte[TR1]
Ageing Resistance
gruene_punkte[2A, 5VIT, 27A, 52VIT, 93A, 101]
Dynamometric Properties
gruene_punkte[TR38, 128P, 129]
Tear Propagation Resistance
gruene_punkte[TR31]
Anti-Slip Surface
gruene_punkte[132PB, 133PB, 134]
Effective Porosity gruene_punkteHigh effective porosity reduces inflammation and the risk of excessive scar formation. [103P, TR33, TR35]
Klinge’s Mesh Classification Class 1a [102P, TR33, TR35]
DynaMesh®-CICAT implants must be placed extraperitoneally in onlay, sublay and/or preperitoneal mesh position.
gruene_punkte Applies to all product sizes
gaue_punkte Does not apply
[#] Reference “#” (see “References”)
[TR#] Internal test report (see “internal test report references”)
Limitations “A” animal trial, “B” bench test, “VIT” in-vitro trial, “P” published results based on the analysis of human mesh explants, “PB” published results mainly based on bench tests

Click here to download Catalogue

  • Full brass+chrome plated
  • Easy to read dual scale gauge with screw-on poly carbonate lens for durability.
  • Precision engineered pressure compensated design flow meter for precise flow.
  • Flow meter with easy to read tube and virtually unbreakable transparent poly carbonate outer cover for strength and 360 visibility.
  • Sintered metal inlet filter to trap impurities.
  • Reliable external safety relief valve.
  • Flush feature permits emergency oxygen to 40LPM.
         
 
 
Features:
  • Can be set as required sterilization temperature, working tem. range:room tem.:+5~126 Degree.
  • Can ge set as required sterilization time of heat preservation, setting range:1~99min.
  • Having a low water to stop heating function.
  • This product uses the high quality stainless steel SUS304. Having to work under normal conditions adequate safety strength.
Technical Specifications:
Model No.: YX280A
Sterilizing volume 18L
Working pressure 0.14-0.16Mpa
Working temperature 126ºC
Max. safety pressure 0.165Mpa
Characteristics Electric heated
Specification : Voltage: AC 220V, 50Hz or 110V, 60Hz Power consumption: 120 W Maximum negative pressure: ≥0.09 MPa Negative pressure range: 0.02 MPa to Max negative pressure Pump rate: ≥20 L/min Noise: ≤60 dB Continuous Working Time: 0-30 min Rest Time≥30min Bottle volume: 2500 ml, 2 pcs Accessory: pedal switch (1pc), power switch(1pc), filter(2 pcs), suction pipe(1pc, 2m in length, silica gel), celiac suction pipe(1pc, 31cm in length, chrome copper) Package: 1pc/carton Box Size : 46.5*41.5*64.5cm Net Weight: 11.5KGS Gross Weight:13.8 KGS
Click Here To Download Catalogue
 
* French imported molecule sieve, long life and more efficiency. * Adopts american PSA technology, use Physical method to separate pure oxygen from air. * Brand-new design, Small size and nice looking * Compact structure design, light weight, easy to move * Advanced oil-free compressor, save 30% power energy * Big LCD Screen easy to operate * Displaying the oxygen concentration in real time. * Optional nebuylizer and oxygen purity alarm function * Power off alarm, abnormal voltage alarm
 
 
This product make the tension of silicon capsule as the driving force to control the flow by micro porous tube, it was pre-selected by doctor base on patients'situation, and then and then handed over to the patients ' self- management “to relieve or ease the pain Product Components: one-way valve medicated device, elastic liquid storage device, liquid medicine filter, current limiting device, automatic liquid feeding device ( CBI & PCA ), pipe and the external connector; Product Features: 1. The continued to liquid (CBI) make the drug-stored sac mechanical stretch as a driving force, limited the flow through the micro porous tube to the patient safely, effectively, slightly, continuous uniform injection of liquid to analgesic effect; extrusion pump body does not affect the liquid normal velocity; liquid filtering device which can control the particles enter the body better; 2. Continued to liquid + self control to liquid ( CBI+PCA ) make the drug-stored sac mechanical stretch as a driving force, limited the flow through the micro porous tube to the patient safely, effectively, slightly, continuous uniform injection of liquid to analgesic effect; Automatic medicated function is the patients can medicate according to pain independently. Extrusion pump body does not affect the liquid normal velocity; liquid filtering device which can control the particles enter the body better; How to use: 1. Get analgesia pump out from sterile packaging, removing the cap of medicine inlet and outlet; pour the analgesic liquid in the liquid storage device, draw out the air from the liquid storage. 2. Finish medicating, waiting for the liquid outflow from the medicine outlet; please clamp tightly to stop flowing for preparation. 3. Control keys (PCA key) is a function key to add the medicine base on continue to medicated by patients' self-controlled. So the patients can self-control the PCA key under the guidance of doctors, according to the needs while they are in treatment. At the same time, doctor should fill in PCA treatment card, so that they can analyze the condition from PCA additional times.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare