Exhaled Nitric Oxide Detector

$3,850.00

Shipped From Abroad

Exhaled nitric oxide detection is to measure the concentration of NO in human exhaled breath, referred to as FeNO detection

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130159-6
Brands:: Ancool

Description

Exhaled Nitric Oxide Analyzer

The test can be performed with just 10 seconds of exhalation, and the test analysis time only takes 60 seconds.

For common diseases in departments such as respiratory medicine, pediatrics, otolaryngology, physical examination, and allergy, such as cough, asthma, chronic obstructive pulmonary disease, etc., during routine clinical examinations, it helps doctors to safely, quickly, and conveniently identify the type of inflammation, assess the level of inflammation, guide treatment, and monitor prognosis.

Detection principle:

Nitric oxide can be produced by a variety of intrinsic cells and inflammatory cells on the surface of the airways under the oxidation of nitric oxide synthase. Allergens and other stimuli induce airway inflammation, and cells such as eosinophils (EOS) release cytokines, activate nitric oxide synthase, and increase airway nitric oxide levels. Currently, FeNO detection can be used to identify chronic airway diseases with similar clinical manifestations such as COPD, asthma, and asthma -COPD overlap syndrome, and can be used to predict the treatment effect and prognosis of COPD patients. FeNO detection helps to improve the diagnosis and treatment of airway inflammatory diseases and can raise the clinical management level of airway inflammation to a new level. FeNO detection has the advantages of accurate results, reliable data, and good repeatability. It is an ideal non-invasive examination technology for airway inflammatory diseases.

Note:

1. Avoid eating, drinking, smoking, strenuous exercise, lung function, or other tests within 1 hour before sampling.

2. Avoid eating foods rich in nitrates or nitrites, such as broccoli, kale, lettuce, celery, radish, and smoked, pickled, or grilled foods within 3 hours.

3. Also ask and record the test time, medication, etc.

Reviews

There are no reviews yet.

Be the first to review “Exhaled Nitric Oxide Detector”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsExhaled Nitric Oxide Detector removeFlexible Endoscope removeMIR Spirobank II Basic removeMIR Spirobank II Advance removeHersill V7 Plus AC High Vacuum Portable Suction Machine removeMIR Minispir Light Spirometer remove
NameExhaled Nitric Oxide Detector removeFlexible Endoscope removeMIR Spirobank II Basic removeMIR Spirobank II Advance removeHersill V7 Plus AC High Vacuum Portable Suction Machine removeMIR Minispir Light Spirometer remove
ImageSpirobank II BasicMIR Spirobank II AdvanceHersill V7 Plus AC High Vacuum Portable Suction Machine
SKUSF1033560130159-6SF103356013089-2SF10335601293SF10335601291SF1033560450-5SF10335601294
Rating
Price

$3,850.00

$0.00

$0.00

$0.00

$359.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Exhaled nitric oxide detection is to measure the concentration of NO in human exhaled breath, referred to as FeNO detection
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features
  • Crystal clear optics
  • Precise motion for perfect control
  • The flexible tip can be moved 130°
  • Waterproof design
  • Supplied in a carrying case with leak tester and Storz/Wolf adaptors
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock
The Spirobank II Spirometer basic is an affordable way for you to offer screening spirometry for a great price to your practice. You can use this spirometer remotely, or you can use it as an online spirometer with your PC. Delivery & Availability: Typically 7-14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock
The new Spirobank II Advanced from MIR is a user-friendly, intuitively operable mobile spirometer that has enough storage space to record up to 10,000 tests and enables immediate diagnosis thanks to the traffic light display. Delivery & Availability: Typically 7-14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The V7 range of high vacuum portable suction units are ideal for use in healthcare facilities (surgery, gynaecology, ENT), homes, ambulances, transportation and use in emergency situations. Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In Stock
The Minispir Light is an economical and easy to use PC spirometer for essential examinations. The Minispir light comes with the Winspiro Light software to help determine the most important parameters for a diagnostic spirometry. Delivery & Availability: Typically 7-14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Exhaled Nitric Oxide Analyzer
The test can be performed with just 10 seconds of exhalation, and the test analysis time only takes 60 seconds. For common diseases in departments such as respiratory medicine, pediatrics, otolaryngology, physical examination, and allergy, such as cough, asthma, chronic obstructive pulmonary disease, etc., during routine clinical examinations, it helps doctors to safely, quickly, and conveniently identify the type of inflammation, assess the level of inflammation, guide treatment, and monitor prognosis.
Detection principle:
Nitric oxide can be produced by a variety of intrinsic cells and inflammatory cells on the surface of the airways under the oxidation of nitric oxide synthase. Allergens and other stimuli induce airway inflammation, and cells such as eosinophils (EOS) release cytokines, activate nitric oxide synthase, and increase airway nitric oxide levels. Currently, FeNO detection can be used to identify chronic airway diseases with similar clinical manifestations such as COPD, asthma, and asthma -COPD overlap syndrome, and can be used to predict the treatment effect and prognosis of COPD patients. FeNO detection helps to improve the diagnosis and treatment of airway inflammatory diseases and can raise the clinical management level of airway inflammation to a new level. FeNO detection has the advantages of accurate results, reliable data, and good repeatability. It is an ideal non-invasive examination technology for airway inflammatory diseases. Note: 1. Avoid eating, drinking, smoking, strenuous exercise, lung function, or other tests within 1 hour before sampling. 2. Avoid eating foods rich in nitrates or nitrites, such as broccoli, kale, lettuce, celery, radish, and smoked, pickled, or grilled foods within 3 hours. 3. Also ask and record the test time, medication, etc.
The flexible Naso-Pharyngo-Laryngoscope is manufactured in Germany to the highest of standards. It is highly suitable for both adult and paediatric use. The high resolution, crystal clear optics ensure sharp image quality. The flexible tip can be moved 150° using the scope’s mechanism. Technical Specifications
Total length
530 mm
Working length
300 mm
Flexible part diameter
3.4 mm or 2.8 mm
Angle deflection
up 150°, down 150°
Angle of vision
70°
Depth of focus
5-50 mm
The Spirobank II Spirometer basic is an affordable way for you to offer screening spirometry for a great price to your practice. You can use this spirometer remotely, or you can use it as an online spirometer with your PC. It works quickly and intuitively with an icon-based navigation menu and features a high-resolution backlit LCD. This is an excellent spirometer for use in primary care, pediatrics, pulmonologists, and Hospitals. 
Spirobank II Basic Features:
  • Fast and intuitive to operate with an icon-based navigation menu
  • Backlit, high-resolution display
  • On screen results and curves preview for immediate data analysis
  • Ideal for family doctors, primary care, occupational medicine, screening.
  • Estimated Lung Age (ELA) test to assess the benefits from smoking cessation
  • Traffic lights for immediate test interpretation
  • Rechargeable, long-life battery (~ 40 hours continous operation)
  • Real-time tests via USB (Bluetooth optional)
  • Memory up to 10,000 tests
  • The tests are analyzed directly on the display without having to connect to a computer.
  • Internal temperature  and pressure sensor for automatic correction
  • Never requires calibration when using disposable turbines
 
Click Here To Download Catalogue
The new Spirobank II Advanced from MIR is a user-friendly, intuitively operable mobile spirometer that has enough storage space to record up to 10,000 tests and enables immediate diagnosis thanks to the traffic light display. The real-time spirometry curve allows the results to be evaluated directly on the device.
MIR Spirobank II Advance Specifications
  • Bluetooth 2.1.
  • Portable spirometer with high resolution display.
  • Quick and intuitive to use thanks to function keys with symbols.
  • User-friendly technology.
  • Backlighting enables use in emergency medicine.
  • With traffic light display.
  • Spirometry analysis also possible directly on the display.
  • Storage space for up to 10,000 spirometry exams.
  • With integrated, powerful battery (approx. 40 operating hours).
  • USB connection for data transfer.
  • Estimated lung age (ELA).
  • With motivational images for children.
  • Optionally available with reusable or disposable turbines.
  • Includes WinspiroPRO software.
  • LCD display with backlight, resolution: 160 x 18.
  • 3.7 V lithium battery, rechargeable.
  • Temperature sensor: semiconducting (0 – 45 ° C).
  • Flow sensor: bi-directional digital turbine.
  • Capacity: 10 liters.
  • Dimensions: 16.0 x 5.5 x 2.5 cm.
   
Click Here To Download Catalogue
The V7 range of high vacuum portable suction units are ideal for use in healthcare facilities (surgery, gynaecology, ENT), homes, ambulances, transportation and use in emergency situations. Features:
  • ABS ergonomical case and ancorage system tested to 10 g.
  • Long life medical grade piston type suction pump. Oil-free and maintenance-free.
  • Vacuum gauge of 0-100 kPa (0-760 mmHg).
  • Precise and stable vacuum control knob.
  • Indicator lights: ON, flashing, vacuum level, vacuum indicator and battery status.
  • Maximum noise level: 49 + 1,5 dB (depending on model).
  • Battery for long duration autonomy (consult models in which it is included). LED battery level lights.
  • Collection jar with overflow safety valve in polycarbonate or polysulfone of 1 L (useful capacity 0.75 L) PC1/PSU1 or 1.75 L (useful capacity 1.30 L) -PC2/PSU2.
  • Also available with holders compatible with the main disposable canister
  • Hydrophobic bacteria filter, made of PTFE. With an efficiency of 99% in the retention of particles and bacteria of 99.99%. With PVC suction tube.
  • ON/OFF swith with moisture protection.
  • Equipment dimensions: 385 x 155 x 255 mm.
Technical Specifications:

Power supply

Flow rate

Maximum vacuum

V7 ac

220 VaC

250 W

20 L/min

80 kPa

600 mmHg

V7 dc

12 VDC

18 W

14 L/min

75 kPa

562 mmHg

V7 plus ac

220 VAC

120 W

30 L/min

84 kPa

630 mmHg

V7 plus dc

12 VDC

85 W

30 L/min

84 kPa

630 mmHg

V7 plus b

12 VDC

85 W

Battery

30 L/min

84 kPa

630 mmHg

V7 plus b emergency

12 VDC

85 W

Battery

30 L/min

84 kPa

630 mmHg

V7 mx

110/240 Vac

12 VDC

160 W (AC) /

84 W (DC)

Battery

30 L/min

84 kPa

630 mmHg

 
Click Here To Download Catalogue 
   

 

 
The Minispir Light is an economical and easy to use PC spirometer for essential examinations. The Minispir light comes with the Winspiro Light software to help determine the most important parameters for diagnostic spirometry.
Minispir Light Specifications
  • Minispir Light PC spirometer.
  • For essential spirometry.
  • Display flow/volume and volume/time curve in real time with before and after comparisons.
  • Intuitive use.
  • COPD and asthma screening.
  • Includes post-medication test.
  • Winspiro Light software.
  • Export data effortlessly inc. via e-mail.
  • With various motivational pictures for children.
  • Measured parameters FVC, FEV1, FEV1%, FEV6, PEF, FEF25-75% FIVC, estimated age lungs, VC, IVC.
  • USB powered.
  • Dimensions: 14.2 x 4.97 x 2.6 cm.
  • Weight: 65 g.
  • Winspiro Light software.
  • Export FVC and VC tests.
  • Combined display flow/volume and volume/time curves.
  • Displays the three best curves per examination.
  • Quality of the tests in the result display.
  • Automatic test interpretation (in result display and print).
  • Traffic light system shows severity of the obstruction/restriction.
 
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare