The Microtome KD-2260 is designed to meet multiple requirements of histology or histopathology labs. It is also suitable for the use in research labs as well as industrial quality assurance. In being manual, the Microtome KD-2260 is flexible to use at any place in the laboratory. With its high-precision mechanics inside, the Microtome KD-2260 permits quality sections, while maintaining a high, consistent throughput. Great functionality and the appealing design are the key features of our microtome. Optimal user comfort enables a rapid, safe and smooth sectioning, even under heavy workload. The integrated sectioning waste tray is resistant to xylene, and can be detached for cleaning.
Technical Specifications:
- Section Thickness Setting Range: 0–60μm
- Section thickness settingoptions:
0–2μm increment 0.25μm
2–10μm increment 1μm
10–20μm increment 2μm
20–60μm increment 5μm
- Trimming Thickness Setting Range: 0- 60μm
- Minimum Setting of Sectioning Thickness: 1μm
- Total Horizontal Specimen Feed:29mm;
- Vertical Specimen Stroke:60mm
- Movement Range of the Base of BladeHolder Base: 0-60mm (front to back)
- Movement Range of the Blade Press plate: 0-23mm
- Specimen Holder Rotation: at any angle within360 degrees
- Maximum Specimen Size: 60×70mm
- Specimen Orientation:XY – 8°
- Precision Error: ±1%
- Dimensions: 570×440×290mm (W×D×H)
- Net weight: 28kg
Review(1)
Quick Comparison
Settings | KEDEE KD-2260 Manual Rotary Microtome remove | Avalun 48 INR Microcuvette remove | Alcohol Pad Per Pack remove | Eppendorf Minispin Centrifuge remove | 8 Bucket Centrifuge remove | Avalun LabPad Device remove | ||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | KEDEE KD-2260 Manual Rotary Microtome remove | Avalun 48 INR Microcuvette remove | Alcohol Pad Per Pack remove | Eppendorf Minispin Centrifuge remove | 8 Bucket Centrifuge remove | Avalun LabPad Device remove | ||||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||
SKU | SF10335601250 | SF1033560084-74 | SF1033560084-64 | SF1033560084-116 | SF1033560084-114 | SF1033560084-65 | ||||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||||
Price | $2,970.00 |
| $4.25 |
| $72.50 |
| ||||||||||||||||||||||||
Stock | Out of stock | |||||||||||||||||||||||||||||
Availability | Out of stock | |||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||||
Description | Ship From Abroad
The Microtome KD-2260 is designed to meet multiple requirements of histology or histopathology labs. It is also suitable for the use in research labs as well as industrial quality assurance. In being manual, the Microtome KD-2260 is flexible to use at any place in the laboratory. Delivery & Availability: Typically 14-21 Working Days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Out stock LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| In stock
| In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | ||||||||||||||||||||||||
Content | The Microtome KD-2260 is designed to meet multiple requirements of histology or histopathology labs. It is also suitable for the use in research labs as well as industrial quality assurance. In being manual, the Microtome KD-2260 is flexible to use at any place in the laboratory. With its high-precision mechanics inside, the Microtome KD-2260 permits quality sections, while maintaining a high, consistent throughput. Great functionality and the appealing design are the key features of our microtome. Optimal user comfort enables a rapid, safe and smooth sectioning, even under heavy workload. The integrated sectioning waste tray is resistant to xylene, and can be detached for cleaning.
Technical Specifications:
| LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users.
Features:
| Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use.
Size and packing of Medical Alcohol pad:
Materials - Non-Woven Fabric
Trademark - OEM/ODM
Specification - CE&ISO13485
| Powerful and user-friendly MiniSpin Centrifuge are small enough so that each workstation can be equipped with a “personal” centrifuge. The rotor, inner centrifuge lid, and lid latch are made of metal for maximum operation safety.
Features:
Click Here To Download Catalogue | 800-1 electric centrifuge is widely used in hospitals, chemical and Biological Chemistry Laboratory for serum, plasma, immune qualitative analysis experiment. Has beautiful shape, large capacity, small volume, complete function. Its performance is stable, the speed is adjustable and can automatically adjust the balance, low temperature, high efficiency and wide applicability and advantages.
Technical Specifications:
Click Here To Download Catalogue | The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
Click Here To Download Catalogue | ||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||
Additional information |
Meshack shiundu
Hello,please email me the operation manual for this brand.Thanks