Description
Features of Mainstream ETCO2 Sensor LH910
NDIR (non-dispersive infrared) technology
Small size and lightweight, long service life, low maintenance cost
Monitoring the patient’s real-time ETCO2, respiration rate, and inspired CO2
Checking and confirming ET tube placement
Alarming when accidental extubating occurs
Detecting ventilator airway connection
Fully compatible with Respironics module’s protocol
Packing List:
Mainstream ETCO2 Sensor * 1pc
Disposable ETCO2 adult airway adapter*1 pc
Disposable ETCO2 Kids airway adapter*1 pc
Specifications of Mainstream ETCO2 Sensor LH910
Principle | NDIR |
Measuring range | 0-150mmHg |
0 – 19.7 % | |
0 – 20 kPa | |
Accuracy | 0-40mmHg @ ±2% of reading, 41-70mmHg @ ±5% of reading, 71-100mmHg @ ±8% of reading, 101-150mmHg @ ±10% of reading. |
Respiration | 3 – 150 BPM; Accuracy: ±1 BPM |
Voltage & Power | 5.0VDC ±5%, 600mA (Sensor Average Power Consumption Less than 1W) |
Interface | RS232, TTL (customized) |
Temp & Humidity | Operating: 0º to 40°, 10 to 90% RH, |
Storage: -40º to 70ºC, <90% RH |
Compatible Brands:
![]() |
![]() |
|
![]() |
Philips | Nihon Kohden | Mindray | Biolight |
![]() |
![]() |
![]() |
![]() |
Bionet, Edan, Yonker,Infinium, DRE, Axia Surgical | Contec | Comen | Masimo |
Quick Comparison
Settings | Mainstream ETCO2 Sensor LH910 remove | CWS 5000- Patient Warming Machine remove | Render SD-M2000A(P) Transport/Portable Anesthetic Machine remove | Timesco Eclipse McCoy Laryngoscope Set remove | MediPlus Bain Circuit (Adult) remove | Render SD-M2000C+ Anesthetic Machine remove | |||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Mainstream ETCO2 Sensor LH910 remove | CWS 5000- Patient Warming Machine remove | Render SD-M2000A(P) Transport/Portable Anesthetic Machine remove | Timesco Eclipse McCoy Laryngoscope Set remove | MediPlus Bain Circuit (Adult) remove | Render SD-M2000C+ Anesthetic Machine remove | |||||||||||||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | |||||||||||||||||||||||||||||||||
SKU | SF1033560130174-1 | SF103356013087-1 | SF1033560011-12 | SF1033560084-54 | SF1033560084-21 | SF1033560011-11 | |||||||||||||||||||||||||||||||||
Rating | |||||||||||||||||||||||||||||||||||||||
Price |
| $1,045.00 | $1,320.00 |
| $28.00 | $4,070.00 | |||||||||||||||||||||||||||||||||
Stock | |||||||||||||||||||||||||||||||||||||||
Availability | |||||||||||||||||||||||||||||||||||||||
Add to cart | |||||||||||||||||||||||||||||||||||||||
Description | Shipped From Abroad
LH910 Mainstream end-tidal CO2 sensor, plug and play, less accessories required, suitable for intubated patients and veterinary monitoring. Compatible with multi-patient monitor brands: Philips, Mindray, Zoll, Comen, Nihon Kohden, Contec, Biolight, Bionet, Edan... Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from Abroad
| In Stock
Sirius-XL Eclipse blades feature a flexible tip designed for difficult intubations and are available in Macintosh 4, 3 and 2. Supplied as a blade only in a case or as a blade and handle set in a case.
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In Stock
| Shipped from Abroad
| ||||||||||||||||||||||||||||||||||
Content | Features of Mainstream ETCO2 Sensor LH910
NDIR (non-dispersive infrared) technology
Small size and lightweight, long service life, low maintenance cost
Monitoring the patient’s real-time ETCO2, respiration rate, and inspired CO2
Checking and confirming ET tube placement
Alarming when accidental extubating occurs
Detecting ventilator airway connection
Fully compatible with Respironics module's protocol
Packing List:
Mainstream ETCO2 Sensor * 1pc
Disposable ETCO2 adult airway adapter*1 pc
Disposable ETCO2 Kids airway adapter*1 pc
Specifications of Mainstream ETCO2 Sensor LH910
Compatible Brands:
| Two speed fan motor and two levels of flow rates. CWS 5000 can inflate a very large blanket as well as a small blanket. • Uses a DC motor, quieter and state of the art blower. • CWS 5000 is controlled and operated through a unique robust software developed by Care Essentials. • The Cocoon™ CWS 5000 is light and compact, yet very sturdy. • Designed to be user friendly. • We comply with all essential regulatory standards. We have FDA, CE, TGA, Japan Health approvals. CWS 5000 has been tested for IEC 60601-1 3rd Edition, AM 1 by UL, USA. |
Click Here To download Catalogue | Sirius-XL Eclipse blades feature a flexible tip designed for difficult intubations and are available in Macintosh 4, 3 and 2. Supplied as a blade only in a case or as a blade and handle set in a case.
Click Here To Download Catalogue |
|
Click Here To Download Catalogue | |||||||||||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | |||||||||||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | |||||||||||||||||||||||||||||||||
Additional information |
Reviews
There are no reviews yet.