Near-Infrared Spectrophotometer

$0.00

Shipped From Abroad

Model : SP-NIR450

An NIR (Near-Infrared) Spectrophotometer measures the absorption of near-infrared light (typically 780-2500 nm) by a sample. It’s widely used in agriculture, pharmaceuticals, and chemical industries for its ability to provide rapid and non-destructive analysis of the chemical composition and physical properties of a sample.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-72
Brands:: Scitek

Description

Near-Infrared Spectrophotometer Features:

1. There is no need to treat the sample before testing to protect the integrity of the sample.

2. 900nm-2500nm ultra-wide spectral range, fast analysis speed.

3. Core parts are all internationally famous brands

4. Built-in high-quality PTFE reference module automatic reference calibration to ensure the accuracy of measurement results.

5. Equipped with integrating sphere diffuse reflection system, large sampling spot and sample turntable

6. All tests use NIST traceable standards.

7. Liquid, powder, support particles, film and other forms of sample detection.

8. The instrument’s real-time environmental temperature and humidity monitoring allows users to optimize the measurement conditions.

9. Simple operation and intuitive user interface.

10. Can establish authoritative and professional near-infrared quantitative and qualitative analysis models.

Near-Infrared Spectrophotometer Specifications:
Model SP-NIR450
Measurement Mode The diffuse reflection sample cell
Detector Japan hamamatsu cooled InGaAs
Spectral Bandwidth(nm) 12
Wavelength Range(nm) 900-2500 nm
Wavelength Accuracy(nm) ≤0.2
Wavelength Repeatability(nm) ≤0.05
Stray Light(%) ≤0.1
Absorbance Noise(Abs) ≤0.0005
Analysis Time 1min (adjustable)
Data Transmission Mode USB2.0
Calibration Technology MPLS Modified least squares regression calibration technology
DPLS Spectrum identification and qualitative analysis technology
Item Content
Electricity 90-250V\50Hz (or 60Hz)
Ambient Temperature (℃) 5-35
Ambient Humidity (%RH) 5-85
Size(W×D×H)(mm) 540×380×220
Shipping Size(W×D×H)(mm) 780x550x400
N.W./G.W. (kg) 18/25

Reviews

There are no reviews yet.

Be the first to review “Near-Infrared Spectrophotometer”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsNear-Infrared Spectrophotometer remove8 Bucket Centrifuge removeErma B-111 Bilirubin Meter removeAvalun LabPad Device removeDiscover 5 Panel Cup with Adulterants Per Pack removeAvalun 48 INR Microcuvette remove
NameNear-Infrared Spectrophotometer remove8 Bucket Centrifuge removeErma B-111 Bilirubin Meter removeAvalun LabPad Device removeDiscover 5 Panel Cup with Adulterants Per Pack removeAvalun 48 INR Microcuvette remove
ImageAvalun Labpad machineDrug Test CupAvalun 48 INR Microcuvette
SKUSF1033560130127-72SF1033560084-114SF1033560084-6SF1033560084-65SF1033560084-23SF1033560084-74
Rating
Price

$0.00

$72.50

$715.00

$0.00

$0.00

$0.00

Stock

Out of stock

AvailabilityOut of stock
Add to cart

DescriptionShipped From Abroad Model : SP-NIR450 An NIR (Near-Infrared) Spectrophotometer measures the absorption of near-infrared light (typically 780-2500 nm) by a sample. It’s widely used in agriculture, pharmaceuticals, and chemical industries for its ability to provide rapid and non-destructive analysis of the chemical composition and physical properties of a sample.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
Classification: Laboratory Centrifuge
Brand Name: xiangtian
Model Number: 800-1
Place of Origin: Jiangsu, China
Time range: 0-60min
Max speed: 4000r/min
Max RCF: 1790xg
Capacity: 20ml*6
  Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self-contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Out stock LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Near-Infrared Spectrophotometer Features:
1. There is no need to treat the sample before testing to protect the integrity of the sample. 2. 900nm-2500nm ultra-wide spectral range, fast analysis speed. 3. Core parts are all internationally famous brands 4. Built-in high-quality PTFE reference module automatic reference calibration to ensure the accuracy of measurement results. 5. Equipped with integrating sphere diffuse reflection system, large sampling spot and sample turntable 6. All tests use NIST traceable standards. 7. Liquid, powder, support particles, film and other forms of sample detection. 8. The instrument's real-time environmental temperature and humidity monitoring allows users to optimize the measurement conditions. 9. Simple operation and intuitive user interface. 10. Can establish authoritative and professional near-infrared quantitative and qualitative analysis models.
Near-Infrared Spectrophotometer Specifications:
Model SP-NIR450
Measurement Mode The diffuse reflection sample cell
Detector Japan hamamatsu cooled InGaAs
Spectral Bandwidth(nm) 12
Wavelength Range(nm) 900-2500 nm
Wavelength Accuracy(nm) ≤0.2
Wavelength Repeatability(nm) ≤0.05
Stray Light(%) ≤0.1
Absorbance Noise(Abs) ≤0.0005
Analysis Time 1min (adjustable)
Data Transmission Mode USB2.0
Calibration Technology MPLS Modified least squares regression calibration technology
DPLS Spectrum identification and qualitative analysis technology
Item Content
Electricity 90-250V\50Hz (or 60Hz)
Ambient Temperature (℃) 5-35
Ambient Humidity (%RH) 5-85
Size(W×D×H)(mm) 540×380×220
Shipping Size(W×D×H)(mm) 780x550x400
N.W./G.W. (kg) 18/25
800-1  electric centrifuge is widely used in hospitals, chemical and Biological Chemistry Laboratory for serum, plasma, immune qualitative analysis experiment. Has beautiful shape, large capacity, small volume, complete function. Its performance is stable, the speed is adjustable and can automatically adjust the balance, low temperature, high efficiency and wide applicability and advantages. Technical Specifications:
Type No.
800-1
Power  source
220V 50HZ     110V  60HZ
Speed Range (rpm)
0~4000(rpm)
Time Range(min)
0-60min
Capacity (ml)
20(ml)×6
Maximum centrifugal force(xg)
1790(xg)
Package Size (cm)
29*29*26
 
Click Here To Download Catalogue
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
  • User-friendly: the LabPad® INR is designed to be easy to use especially thanks to its 3D-shaped microcuvette that only requires a small drop of blood from a fingertip. Thanks to the color screen, both measurement steps and browsing the list of results are easy to visualize.
  • Quick and reliable: the reliability of INR results is obtained by quality controls that are performed automatically before each measurement. In less than one minute, you can see if you are in your therapeutic range.
  • Connected: the result obtained after performing the test can be transferred to healthcare professionals in charge of your treatment monitoring. This result is complementary to the pie charts and trend reports directly displayed on the LabPad® INR to help you monitoring your treatment
 
Click Here To Download Catalogue
   
All-in-One Design
FDA 510K & CLIA Waived 99% Accurate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 14 substances Adulterants available
 
 
LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users.
Features:
  • Fully automated "plug-and-play"   behavior
  • Reduced blood volume (only 3µL)
  • A large space for blood drop-off
  • Fills up quickly, using just capillarity
  • Easy handling, thanks to its 3D shape
  • Optimized preservation in individual pouches, in boxes of 12, 24, or 48 units
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare