New
/

NEUROSTIM-Transcranial Electrical Stimulator

$0.00

Shipped From Abroad

NEUROSTIM is a Transcranial Electrical Stimulator (TES) designed for neuromodulation, neuroprotection, and rehabilitation. It delivers precise electrical stimulation to targeted brain areas, aiding in motor cortex mapping, neurological recovery, and cognitive enhancement. Ideal for neurologists, neurosurgeons, and rehabilitation specialists, NEUROSTIM ensures safe, effective, and customizable stimulation for both clinical and research applications. With its advanced technology and user-friendly interface, it enhances treatment precision and patient outcomes in neuroscience and neurorehabilitation.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: Neurosoft

Description

DC output current – up to 2mA

Neurostim is intended for the transcranial noninvasive stimulation with direct low current (up to 2 mA).

The current generates the electrical field changing the brain cortex excitability. Such brain impact has therapeutic effect in the treatment of different disorders including fibromyalgia, major depressive episode, addiction/craving, lower limb neuropathic pain and recovery of motor functions after stroke and brain injuries.

Continuous monitoring of electrode impedance

It is very important to keep the reliable skin-electrode contact during the whole stimulation procedure. Poor electrode contact due to improper electrode placement or dry-out can result in decreased therapeutic effect.  Neurostim ensures continuous impedance monitoring. If the electrode impedance is too high, a notification will sound and the stimulation will be terminated (paused).

Two modes of use: inpatient  and outpatient

For inpatient treatment Neurostim is supplied with pre-defined treatment protocols for most commonly used therapy. Just select the protocol for the particular patient from the list.

For outpatient treatment you should create a treatment course (up to 250 stimulation sessions). A patient will start the treatment sessions one by one. The completed session will be locked and cannot be used for the treatment.

USB connection for advanced control

The software can be used to control and adjust stimulator through USB. In this mode the stimulator is also powered through USB.  The software is a simple way to manage the session list. You can add, remove, edit, import and export session, download user-defined waveform.

Features
  • smulus current – up to 5 mA (30 V)
  • smulaon duraon – up to 40 min
  • smulus type:
  • tDCS (transcranial direct current smulaon)
  • tACS (transcranial alternang current smulaon)
  • tRNS (transcranial random noise smulaon)
  • tDCS-Sham (transcranial direct current smulaon + sham)
  •  tPCS (transcranial pulse current smulaon) custom waveform
  • secure administrator mode to set up sessions
  • operaon modes:
  • stand-alone
  • USB-controlled (smulaon by specified protocol; creaon and eding of smulaon protocols)
Specifications
  • 1 channel transcranial smulator for unipolar (DC) and bipolar (AC) smulaon
  • adjustable smulus current of 0 up to 5 mA with 25 µA increment
  • adjustable smulaon duraon of 15 s to 40 min with 5 s increment
  • 16 bit D/A conversion
  • sampling rate:
    tACS – 33 kHz
    tRNS – 10 kHz
    tDCS – 500 Hz
    tPCS – 10 kHz
  • storage – 250 smulaon sessions
  •  power supply: from 9 V baery of 6LR61 or HR22 type or rechargeable batteries (up to 3 hours)
    from USB of +5 V (galvanically isolated up to 4000 V)

Download Brochure

Reviews

There are no reviews yet.

Be the first to review “NEUROSTIM-Transcranial Electrical Stimulator”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsNEUROSTIM-Transcranial Electrical Stimulator removeDolphin-MAX Transcranial Doppler Probe removeBRAINSWAY Deep TMS H7 RCT Coil removeVentMed Sleep Fairy A9 removeDolphin-IQ Transcranial Doppler Probe removeEctron Ectonustim Series 6 Electroconvulsive Therapy ECT Machine remove
NameNEUROSTIM-Transcranial Electrical Stimulator removeDolphin-MAX Transcranial Doppler Probe removeBRAINSWAY Deep TMS H7 RCT Coil removeVentMed Sleep Fairy A9 removeDolphin-IQ Transcranial Doppler Probe removeEctron Ectonustim Series 6 Electroconvulsive Therapy ECT Machine remove
Image
SKUSF1033560130142-2SF1033560130142-3SF10335601235
Rating
Price

$0.00

$0.00

$0.00

$0.00

$6,325.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad NEUROSTIM is a Transcranial Electrical Stimulator (TES) designed for neuromodulation, neuroprotection, and rehabilitation. It delivers precise electrical stimulation to targeted brain areas, aiding in motor cortex mapping, neurological recovery, and cognitive enhancement. Ideal for neurologists, neurosurgeons, and rehabilitation specialists, NEUROSTIM ensures safe, effective, and customizable stimulation for both clinical and research applications. With its advanced technology and user-friendly interface, it enhances treatment precision and patient outcomes in neuroscience and neurorehabilitation.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Transcranial Doppler machine with an integrated rechargeable battery. The Dolphin/MAX is the ideal portable TCD system for measurements of cerebral blood flow in Neurology, ICU, and Neurosurgery settings
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The H7 Coil stimulates the anterior cingulate cortex and the medial prefrontal cortex.  Treatment is designed to regulate the CSTC circuit believed to be involved in the inhibition of impulsive behavior. A sham coil is integrated above the treatment coil. To the patient and operator, the helmet appears the same, pulses sound the same, and stimulation feels the same on the scalp.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad VentMed sleep monitor device is a brand new intelligent diagnosis system for sleep disorders and sleep apnea, suitable for clinic, hospital, sleep centre, home use study and screening of Sleep Apnea Syndrome (SAS).
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad All of the advantages and performance of the cutting-edge Dolphin TCD technology for measurements of cerebral blood flow velocities are implemented in the smart and compact Dolphin/IQ Transcranial Doppler module.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad

This machines have been developed from the well-proven Series 5A and 5B ECT apparatus. The series 6+ models incorporate all the features of the corresponding Series 5B versions. Experience has shown that a very few patients sometimes require higher dosage than was available with the earlier machines and the opportunity was therefore taken to produce equipment with a second, higher, output range.

Delivery & Availability: Typically 3 Months – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentDC output current – up to 2mA Neurostim is intended for the transcranial noninvasive stimulation with direct low current (up to 2 mA). The current generates the electrical field changing the brain cortex excitability. Such brain impact has therapeutic effect in the treatment of different disorders including fibromyalgia, major depressive episode, addiction/craving, lower limb neuropathic pain and recovery of motor functions after stroke and brain injuries. Continuous monitoring of electrode impedance It is very important to keep the reliable skin-electrode contact during the whole stimulation procedure. Poor electrode contact due to improper electrode placement or dry-out can result in decreased therapeutic effect.  Neurostim ensures continuous impedance monitoring. If the electrode impedance is too high, a notification will sound and the stimulation will be terminated (paused). Two modes of use: inpatient  and outpatient For inpatient treatment Neurostim is supplied with pre-defined treatment protocols for most commonly used therapy. Just select the protocol for the particular patient from the list. For outpatient treatment you should create a treatment course (up to 250 stimulation sessions). A patient will start the treatment sessions one by one. The completed session will be locked and cannot be used for the treatment. USB connection for advanced control The software can be used to control and adjust stimulator through USB. In this mode the stimulator is also powered through USB.  The software is a simple way to manage the session list. You can add, remove, edit, import and export session, download user-defined waveform.
Features
  • smulus current – up to 5 mA (30 V)
  • smulaon duraon – up to 40 min
  • smulus type:
  • tDCS (transcranial direct current smulaon)
  • tACS (transcranial alternang current smulaon)
  • tRNS (transcranial random noise smulaon)
  • tDCS-Sham (transcranial direct current smulaon + sham)
  •  tPCS (transcranial pulse current smulaon) custom waveform
  • secure administrator mode to set up sessions
  • operaon modes:
  • stand-alone
  • USB-controlled (smulaon by specified protocol; creaon and eding of smulaon protocols)
Specifications
  • 1 channel transcranial smulator for unipolar (DC) and bipolar (AC) smulaon
  • adjustable smulus current of 0 up to 5 mA with 25 µA increment
  • adjustable smulaon duraon of 15 s to 40 min with 5 s increment
  • 16 bit D/A conversion
  • sampling rate: tACS – 33 kHz tRNS – 10 kHz tDCS – 500 Hz tPCS – 10 kHz
  • storage – 250 smulaon sessions
  •  power supply: from 9 V baery of 6LR61 or HR22 type or rechargeable batteries (up to 3 hours) from USB of +5 V (galvanically isolated up to 4000 V)
Download Brochure
https://youtu.be/Id0Ma1_lEo0?si=-B5sGwSCDZOQi-ZO
Features of Dolphin TCD Machine

Best Quality Doppler

Fully digital Doppler technology with the amazing Dolphin TCD post-processing capabilities. Review and replay the blood flow waveforms with audio at ANY depth. Discover unmatched clinical diagnosis capabilities.

Best TCD Robotic Probe

The unique Dolphin/XF robotic probe changes the Transcranial Doppler monitoring market as is known to date. Fast and simple scanning is achieved thanks to special algorithms and processes for blood flow detection. The Dolphin/XF robot is comfortable and stable, simplifying probe fixation and saving time.

Continuous Monitoring Made Easy

The Dolphin TCD Products are designed to assist in performing short or long-term patient monitoring. The famous Dolphin Quick-Lock provides the best locking solution. The TCD software is rich with quality features for optimal patient diagnosis.

Unbeatable Durability and Reliability

The Dolphin is considered by many as the most reliable Transcranial Doppler machine in the market. Robust TCD equipment and high-quality Doppler probes are designed for all TCD clinical applications.

Designed for Portability

The slim and lightweight design of the Dolphin TCD machines allows ideal and comfortable portability. The large touch screen can easily be seen from a distance. Mounting the TCD on a trolley is simple and easy. The Dolphin/MAX has a built-in integrated battery that lasts for hours.

Complete Network Connectivity

The unmatched Dolphin connectivity capabilities are ideal for hospital IT personnel and EMR / PACS administrators. Simple plug-and-play operation allows connectivity configuration with automated DICOM Worklist & Storage, Structured Report, and HL7. Unlimited Review Stations for interpretation and reporting in the comfort of your office.

Unmatched HITS Detection

Simultaneous counts of suspected embolic events in all depth gates using a high-resolution proprietary algorithm. Includes numerous advanced emboli analysis options with the proprietary super high-resolution power M Mode display during HITS detection.
The Brainsway Deep TMS H7 RCT Coil is a flexible coil used in transcranial magnetic stimulation (TMS) to treat obsessive-compulsive disorder (OCD) and other neuropsychiatric conditions:
  • What it does
    The H7 Coil stimulates the medial prefrontal cortex and the anterior cingulate cortex of the brain. TMS uses magnetic pulses to create an electrical current in the brain's neuronal tissue. 
  • How it's used
    The H7 Coil is integrated into a cooled, cushioned helmet that allows the patient to move around during treatment. A sham coil is also included so that the patient and operator can't tell the difference between the treatment and sham coils. 
  • What it's used for
    The H7 Coil is FDA-cleared for OCD, but it's also been shown to be effective in treating other conditions, including addiction, major depressive disorder, and autism spectrum disorder. 
  • How it works
    The H7 Coil is designed to regulate the CSTC circuit, which is thought to be involved in impulsive behavior. 
  • Safety
    A 2023 paper that analyzed adverse events from five large, randomized controlled trials found that most adverse events were transient and resolved within days.
Features
  • Stimulates specific brain regions
    The H7 Coil targets the anterior cingulate cortex and the medial prefrontal cortex. 
  • Flexible windings
    The H7 Coil's flexible windings conform to the shape of the patient's head. 
  • FDA-cleared for OCD
    The H7 Coil is FDA-cleared for treating obsessive-compulsive disorder (OCD). 
  • Demonstrated efficacy
    The H7 Coil has been shown to be effective in treating OCD patients with varying degrees of severity and comorbidities. 
  • Integrated sham coil
    The helmet includes a sham coil that makes the treatment appear, sound, and feel the same to the patient and operator.

Click here to download Brochure

The VentMed Sleep Fairy is a sleep monitoring device designed for diagnosing sleep disorders, including sleep apnea. It is available in models such as the Sleep Fairy A7 and Sleep Fairy A9, both of which offer home-based and clinical sleep studies.
Key Features:
  • Advanced Monitoring: Tracks airflow, snoring, SpO2 levels, pulse rate, and body position.
  • 3D Gyroscope Technology: Detects chest and abdominal movement with high sensitivity.
  • User-Friendly Interface: Features a 2.8-inch TFT display and a simple one-switch operation.
  • Data Recording & Reports: Stores sleep data on a 16GB SD card, generating multiple reports for physicians.
  • Compatibility with CPAP: Can be linked to CPAP devices for pressure titration.
  • Compact & Portable: Smallest and lightest sleep monitor, making it easy to use at home.
  • Battery Life: The A9 model has a rechargeable lithium battery that provides up to 30 hours of continuous monitoring​.
Intended Use:

The VentMed Sleep Fairy is suitable for:

  • Home sleep studies
  • Clinics and hospitals
  • Screening for Sleep Apnea Syndrome (SAS)
  • Integration with CPAP therapy
 
Specifications
Category Specification
Brand VentMed
Model Sleep Fairy A9
Device Type Sleep Apnea Monitoring Device
Usage Home sleep testing, clinical sleep studies
Display 2.8-inch TFT screen (320x240 resolution)
Weight 176g (including battery)
Storage 16GB SD card (stores over 16,000 hours of data)
Battery Rechargeable Lithium Battery (2500 mAh)
Battery Life Up to 30 hours of continuous monitoring (more than 4 nights)
Power Source Plug-in
Monitoring Features - Airflow - Snoring levels - Blood Oxygen Saturation (SpO2: 70% - 100%) - Pulse Rate (30 - 240 bpm) - Body Position - Chest & Abdomen movement (via 3D Gyroscope)
Data Transfer SD Card storage
Report Formats PDF, Word, Customizable templates
Operating System Support Windows XP, 7, 8, 10
User Interface Friendly UI with graphical design
Certifications CE / ISO13485
Instrument Classification Class II Medical Device
Compliance AASM (American Academy of Sleep Medicine) requirements
https://youtu.be/Id0Ma1_lEo0?si=kRJ1bUMjUCBuCAqR  
Features of Dolphin TCD Machine

Best Quality Doppler

Fully digital Doppler technology with the amazing Dolphin TCD post-processing capabilities lets you review and replay the measured spectrum with audio at any depth. Unmatched clinical diagnosis capabilities.

Best TCD Robotic Probe

The unique Dolphin/XF robotic probe changes the Transcranial Doppler monitoring market as is known to date. Fast and simple scanning is achieved thanks to special algorithms and processes for blood flow detection. The Dolphin/XF robot is comfortable and stable, simplifying probe fixation and saving time.

Continuous Monitoring Made Easy

The Dolphin devices are well designed to assist the technician or physician in performing short or long-term Monitoring. The Dolphin Headset design comes with the unique probe Quick-Lock – the best locking solution. The Dolphin software is rich with quality features for optimal patient diagnosis, including a complete replay of the entire recording, placement of automatic and predefined markers, and availability of trends display.

Unbeatable Durability and Reliability

The Dolphin is considered by many as the most reliable Transcranial Doppler machine in the market. A range of high-quality Doppler probes is available for different clinical applications and optimal Doppler penetration of the temporal window.

Designed for Portability

The Dolphin TCD machines are the most portable TCD machine on the market. Dolphin/MAX and Dolphin/4D are slim, lightweight, and have a large 18″ Touch Screen, which can be seen from a distance in the ICU or other clinical settings. Their design allows you to simply hand carry them or use the VESA mount options to easily connect the TCD system to a cart or trolley. The Dolphin/MAX has a built-in integrated battery that lasts for hours.

Complete Network Connectivity

The unmatched Dolphin connectivity capabilities are ideal for hospital IT personnel and EMR / PACS administrators. The advanced Dolphin TCD networking abilities allow a simple plug-and-play operation to quickly configure connectivity with automated DICOM Worklist & Storage, Structured Report, and HL7. With unlimited Review Stations, measurements can be reanalyzed and interpreted from the comfort of your office. Final reporting can also be configured and finalized from any location.

Unmatched HITS Detection

Optimal and accurate counts of suspected embolic events using a high-resolution proprietary algorithm that simultaneously detects HITS (emboli events) in all gates! The numerous advanced analysis options of each suspected emboli include an extraordinary high-resolution power M Mode display during HITS detection (up to 50 times faster than the Doppler spectrum!).
This machines have been developed from the well-proven Series 5A and 5B ECT apparatus. The series 6+ models incorporate all the features of the corresponding Series 5B versions. Experience has shown that a very few patients sometimes require higher dosage than was available with the earlier machines and the opportunity was therefore taken to produce equipment with a second, higher, output range. Features: Constant Current stimulus Delivered Dosage Displayed Patient Dynamic Impedance Indicator Simple Single Dose Control Technical Specification: Input Supply: AC 100-120, 210-240 V 40/60 Hz Load: 70 W Apparatus Size: 305 x 170 x 105mm (12” x 6.5” x 4”) Weight: 3.24kg Low Range: 50-700mC @ 750mA High Range: 200-100mC @ 900mA Contents: Two-hand headpiece: 1 C.S lead: 1 Disposable electrodes: 50 Mains cable: 1 Operating & service manual: 1 Removable stand: 1  
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare