Pensky-Martens Closed Cup Flash Point Tester PE-TVZ
$0.00
Shipped From Abroad
Purpose:
The flash point tester PE-TVZ is intended for usage as laboratory equipment to perform closed cup flash point determination of oil products according to method B EN ISO 2719: 2002 and ASTM D93 are considered for oil products testing.
Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Purpose:
The flash point tester PE-TVZ is intended for usage as laboratory equipment to perform closed cup flash point determination of oil products according to method B EN ISO 2719: 2002 and ASTM D93 are considered for oil products testing.
Technical specifications:
– Maximum heating temperature, °C – up to 370
– Power supply voltage from AC mains with frequency of 50Hz, V – 220±22
– Power consumption, no higher than, W – 400
– Instrument weight, kg – 6.8
– Service life, years at least – 5
Operation conditions:
– Air temperature, °C – 15?35
– Relative humidity, % – 30?90
– Overall dimensions (body), mm:
– Length, mm – 307
– Width, mm – 255
– Height, mm – 153
– Range of flash point determination, °C – 25-370
– Ignition device, type – oil
Complete set:
1. Pensky-Martens Closed Cup Flash Point Tester PE-TVZ- 1 pc.
2. Thermometer- 1pc.
3. Operation manual- 1 pc.
4. ASTM D93
5. Stowage box- 1 pc.
Quick Comparison
Settings | Pensky-Martens Closed Cup Flash Point Tester PE-TVZ remove | ApexBio HemoSmart Gold Hemoglobin Meter remove | Discover 14 Panel Cup with Adulterants Per Pack remove | Automatic Pipette remove | Erma B-111 Bilirubin Meter remove | Discover 5 Panel Cup with Adulterants Per Pack remove |
---|---|---|---|---|---|---|
Name | Pensky-Martens Closed Cup Flash Point Tester PE-TVZ remove | ApexBio HemoSmart Gold Hemoglobin Meter remove | Discover 14 Panel Cup with Adulterants Per Pack remove | Automatic Pipette remove | Erma B-111 Bilirubin Meter remove | Discover 5 Panel Cup with Adulterants Per Pack remove |
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() |
SKU | SF10335601078 | SF1033560084-29 | SF1033560084-28 | SF1033560084-130 | SF1033560084-6 | SF1033560084-23 |
Rating | ||||||
Price |
| $55.00 |
|
| $715.00 |
|
Stock | ||||||
Availability | ||||||
Add to cart | ||||||
Description | Shipped From Abroad
Purpose:
The flash point tester PE-TVZ is intended for usage as laboratory equipment to perform closed cup flash point determination of oil products according to method B EN ISO 2719: 2002 and ASTM D93 are considered for oil products testing.
Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In Stock
HemoSmart GOLD offers a fast and easy way to measure hemoglobin level and is the first biosensor-based palm sized hemoglobin testing system in the world.The one of its kind strip-based testing method offers ease of use and portability and requires only 1μL of blood.
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self contained and the entire cup is tamper resistant.
Delivery & Availability:
| In stock
| Shipped From Aboard
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self-contained and the entire cup is tamper resistant.
Delivery & Availability:
|
Content | Purpose: The flash point tester PE-TVZ is intended for usage as laboratory equipment to perform closed cup flash point determination of oil products according to method B EN ISO 2719: 2002 and ASTM D93 are considered for oil products testing. Technical specifications: - Maximum heating temperature, °C - up to 370 - Power supply voltage from AC mains with frequency of 50Hz, V - 220±22 - Power consumption, no higher than, W - 400 - Instrument weight, kg – 6.8 - Service life, years at least – 5 Operation conditions: - Air temperature, °C - 15?35 - Relative humidity, % - 30?90 - Overall dimensions (body), mm: - Length, mm - 307 - Width, mm - 255 - Height, mm - 153 - Range of flash point determination, °C - 25-370 - Ignition device, type - oil Complete set: 1. Pensky-Martens Closed Cup Flash Point Tester PE-TVZ- 1 pc. 2. Thermometer- 1pc. 3. Operation manual- 1 pc. 4. ASTM D93 5. Stowage box- 1 pc. | HemoSmart GOLD offers a fast and easy way to measure hemoglobin level and is the first biosensor-based palm sized hemoglobin testing system in the world.The one of its kind strip-based testing method offers ease of use and portability and requires only 1μL of blood.
Feature
Click Here To Download Catalogue |
All-in-One Design
| This Automatic Pipette will help you get your lab up and running in no time—at a great price!
Features:
| The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric
analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Feature
|
All-in-One Design
|
Weight | N/A | N/A | N/A | N/A | N/A | N/A |
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A |
Additional information |
Reviews
There are no reviews yet.