Scanning Visible Spectrophotometer

$0.00

Shipped From Abroad

Scanning Visible Spectrophotometer measures the intensity of light absorbed by a sample across the visible spectrum (400-800 nm) by scanning through different wavelengths. It uses a monochromator to separate light into its component wavelengths, which are then passed through the sample. This method provides detailed absorption spectra, useful for precise chemical analysis and research.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-55
Brands:: Scitek

Description

Visible Spectrophotometer Features:

SP-V723 has the features of a compact structure, complete functions, high-cost performance. You can use it in drug analysis, water quality control analysis, biochemical and clinical testing, material research, food testing, etc.

  1. Automatic wavelength detection and calibration, making the wavelength precision high.
  2. Wide wavelength range to meet the needs of most spectrophotometric tests.
  3. High scanning speed to improve working efficiency.
  4. High photometric accuracy improves the efficiency of the assembly process.
  5. Offline U disk storage, convenient for users to manage data in Excel and other formats.
  6. Equipped with a USB port, you can communicate online without setting any parameters.
  7. The electronic system adopts a 32-bit ARM core processor with various offline quantitative measurement functions.

 

Visible Spectrophotometer Specifications:
Model SP-V723
Wavelength Range 320nm-1100nm
Wavelength Accuracy ±1nm
Wavelength Repeatability ≤0.5nm
Bandwidth 2nm
Photometry Accuracy ±0.5%T
Photometry Repeatability ≤0.2%T
Stray Light ≤0.1%T(220nm, NaI)
Baseline Flatness ±0.002A
Stability ≤0.0008A
Noise ≤0.5%T(100%T), ≤0.2%T(0%T)
Photometry Range 0.0~200%(T), -0.3~4(A)
Display System 128×64 LCD Display
Functional Port USB-A(U Disk), USB-B(PC), Serial Port(Printer)
Size(W×D×H)(mm) 370×357×220
Shipping Size(W×D×H)(mm) 450×420×310
N.W./G.W. (kg) 8/11

Reviews

There are no reviews yet.

Be the first to review “Scanning Visible Spectrophotometer”

Your email address will not be published. Required fields are marked *

Quick Comparison

Scanning Visible Spectrophotometer removeAutomatic Pipette removeMotic BA210 Series Biomedical Microscope removeAlcohol Pad Per Pack removePlastic Urine Container Per Pack removeiSED Fully Automated ESR Analyzer remove
NameScanning Visible Spectrophotometer removeAutomatic Pipette removeMotic BA210 Series Biomedical Microscope removeAlcohol Pad Per Pack removePlastic Urine Container Per Pack removeiSED Fully Automated ESR Analyzer remove
Image
SKUSF1033560130127-55SF1033560084-130SF1033560084-78SF1033560084-64SF1033560084-106SF1033560084-129
Rating
Price

$0.00

$0.00

$0.00

$4.25

$8.20

$0.00

Stock
Availability
Add to cart

DescriptionShipped From AbroadScanning Visible Spectrophotometer measures the intensity of light absorbed by a sample across the visible spectrum (400-800 nm) by scanning through different wavelengths. It uses a monochromator to separate light into its component wavelengths, which are then passed through the sample. This method provides detailed absorption spectra, useful for precise chemical analysis and research.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
This Automatic Pipette will help you get your lab up and running in no time—at a great price! Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock The BA210 series is a line of basic biological microscopes manufactured by Motic. The unit is equipped with Motic Infinity Optics (CCIS®, offering quality performance in the fields of education and training. The device features a coaxial coarse and fine housing with a quadruple reverse-mounted nose piece. Its contrast methods, such as phase contrast, polarization and dark field, are easily performed through optional accessories. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Visible Spectrophotometer Features:
SP-V723 has the features of a compact structure, complete functions, high-cost performance. You can use it in drug analysis, water quality control analysis, biochemical and clinical testing, material research, food testing, etc.
  1. Automatic wavelength detection and calibration, making the wavelength precision high.
  2. Wide wavelength range to meet the needs of most spectrophotometric tests.
  3. High scanning speed to improve working efficiency.
  4. High photometric accuracy improves the efficiency of the assembly process.
  5. Offline U disk storage, convenient for users to manage data in Excel and other formats.
  6. Equipped with a USB port, you can communicate online without setting any parameters.
  7. The electronic system adopts a 32-bit ARM core processor with various offline quantitative measurement functions.
 
Visible Spectrophotometer Specifications:
Model SP-V723
Wavelength Range 320nm-1100nm
Wavelength Accuracy ±1nm
Wavelength Repeatability ≤0.5nm
Bandwidth 2nm
Photometry Accuracy ±0.5%T
Photometry Repeatability ≤0.2%T
Stray Light ≤0.1%T(220nm, NaI)
Baseline Flatness ±0.002A
Stability ≤0.0008A
Noise ≤0.5%T(100%T), ≤0.2%T(0%T)
Photometry Range 0.0~200%(T), -0.3~4(A)
Display System 128×64 LCD Display
Functional Port USB-A(U Disk), USB-B(PC), Serial Port(Printer)
Size(W×D×H)(mm) 370×357×220
Shipping Size(W×D×H)(mm) 450×420×310
N.W./G.W. (kg) 8/11
This Automatic Pipette will help you get your lab up and running in no time—at a great price! Features:
  • Lowest operation and tip ejection forces
  • Fully autoclavable
  • Ultra light weight with space-age materials
  • Secondary adjustment option for various liquid classes
  • Spring loaded tip con
  • For transferring molecular samples and PCR mix solutions.
  • One set is for DNA work and the other for RNA work. Each with the following specs
  • Light weight, traditional tip shaft, and will fit all generic brands of tips
  • Equal to or better than accuracy and precision compared to ISO 8655, so results can be trusted.
  • Easy and quick volume adjustment with or without gloves. Foolproof volume lock prevents accidental volume changes.
  • Low maintenance and autoclavable 121° for at least 20 minutes
  • Quick release
The BA210 series is a line of basic biological microscopes manufactured by Motic. The unit is equipped with Motic Infinity Optics (CCIS®, offering quality performance in the fields of education and training. The device features a coaxial coarse and fine housing with a quadruple reverse-mounted nose piece. Its contrast methods, such as phase contrast, polarization and dark field, are easily performed through optional accessories. Technical applications: Biomedical Type: Optical Observation technique: Dark field Magnification: 4 unit, 10 unit, 40 unit, 100 unit  Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Size and packing of Medical Alcohol pad:
  • Pad Size: Unfolded: 30 x 60 mm (other size can be request ).
  • Folded: 30x30 mm, 30 x 35mm,can be 2ply or 4ply ( other size, ply can be request ).
  • Aluminum Package: 60 x 50 mm , 50 x 50mm approximate ( other size can be request ).
  • Packing: 100/200 pcs per inner box, 50/ 100 boxes per carton(packing can be request).
Use of Medical Alcohol pad:
  • For cleaning prior to injection or to disinfect the hurted skin for family and medical treatment organization use.
  • For preparation and immediate disinfection of skin, wound area orr Instrument and utensil.
Notice of Medical Alcohol pad:
  • Not for eyes;
  • keep out of reach of children;
  • For external use only;
  • please stop using if you feel allergic or amyctic
Materials - Non-Woven Fabric
Trademark - OEM/ODM
Specification - CE&ISO13485
   
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr. Features:
  • Results in 20 Seconds

  • 100µL sample drawn directly from primary EDTA tube

  • Fully automated, walk-away operation

  • Random access

  • Positive patient identification via internal barcode reader

  • Compatible with pediatric tube

     
Technical Specifications: 
Principle of Measure: Photometrical
Results: “Printed mm/hr, Range from 1-130 mm/hr”
Sample Requirements: 500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated.
Tube Requirements: 13 x 75 mm, pierceable capped tube
Quality Control: Barcoded Seditrol® QC
Barcode Reader: Internal
Printer: Internal
Interface Specifications: serial RS232 port for LIS connection
Weight: 14 kg
Dimensions (H x W x D): 36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in)
Voltage: 100-240VAC
Frequency Range: 50-60 Hz
Power: 160W
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare