Content | Features
Full color TFT 7” display with PCAD (projected capacitive) touchscreen. Size and tilt of the display allow an easy and effortless selection of the parameters and increase user safety.
All required parameters and functions are available on the main screen: section mode, section and trimming thickness, section counter, section sum, remaining travel, retraction and coarse feed, memory function.
MEM key for higher productivity, to retrieve previous cuttings settings when working with uniform paraffin blocks. By simply pressing a key, the specimen moves into the stored MEM position.
Thanks to a blocking mechanism the easy to operate change system allows to work with different specimen clamps. Indication of 0-position in x and y direction by palpable “click” for the precise alignment of the specimen.
Precise, motorized coarse feed in two modes, continuous and step. In continuous mode, speed is selectable between slow and fast to ensure a controlled specimen approach.
- Quick release specimen clamp
Cutting-edge design of the specimen clamp that prevents building up of dirt and facilitates operations with the microtome. The retraction function selectable between 5 -250μ can be deactivated, although it is advisable as it prolongs the life of the blade. ( Default value 40 μ)
Special antistatic coating prevents paraffin adhesion and minimizes the cleaning time. Ergonomic design with surface for arm rest. Wide area on the top of the microtome for the storage of tools.
Blade holder slides sideways in both directions allowing the use of the entire cutting edge. It accepts low- and high-profile blades. All blade holders are equipped with finger guard for safety reasons.
- Smooth and ergonomic handwheel
The handwheel is perfectly balanced thanks to an innovating counterweight system and can be locked in any angular position. Cutting can be done by turning the handwheel clockwise or counterclockwise.
Technical Data Microtome M-240
Section thickness |
|
Total range in (μm) |
0,5 – 100 |
Thickness settings in (μm) |
|
|
0,5 – 5 in increments of 0,5 |
|
5 – 20 in increments of 1 |
|
20 – 60 in increments of 5 |
|
60 – 100 in increments of 10 |
Trimming |
|
Total range in (μm) |
1 – 600 |
Thickness settings in (μm) |
|
|
1 – 10 in increments of 1 |
|
10 – 20 in increments of 2 |
|
20 – 50 in increments of 5 |
|
50 – 100 in increments of 10 |
|
100 – 600 in increments of 50 |
Specimen feed (mm) |
28 ± 1 mm |
Vertical stroke (mm) |
72 ± 1 mm to allow sectioning of mega-cassettes |
User interface |
7” capacitive touchscreen display |
Operating modes |
Rotational or Rocking (selectable) |
Specimen retraction |
Optional function that can be deactivated |
Total range in (μm) |
5 – 250 μm (selectable in 1 μm increment) |
|
5 predefined values: 20, 30, 40, 60, 80 μm |
|
Default value: 40 μm |
Motorized coarse feed (μm/sec) |
|
|
300 (slow speed forward) |
|
800 (fast speed forward) |
|
1800 (ultrafast speed backward) |
|
Additional function for forward/backward coarse feed in step mode |
Blade Holder Type |
Two in One for high- and low-profile blades |
Max. specimen size |
50x60x40 mm (w x h x d)
Super cassette clamp 68x48x15 mm |
Specimen orientation |
|
|
± 8º horizontal and vertical |
|
Rotational capability: 360º |
|
Indication of 0-position by means of click (x and y direction) |
Power requirements |
100-240 VAC / 50-60Hz |
Consumption |
40 VA |
Dimensions |
|
Width |
465 mm |
Depth with tray |
540 mm |
Height |
298 mm |
Weight |
33,9 kg |
| Binocular gemological stereomicroscopes for brightfield and darkfield applications with special side-emitting LED illumination ring for true darkfield illumination. Equipped also with an incident LED flexible arm and a diffusive LED disc for transmitted illumination. The instrument can be easily tilted horizontally for immersion analysis.
Features:
- Observation mode: Brightfield, darkfield.
- Heads: Binocular, 45° inclined, 360° rotating.
- Interpupillary distance: Adjustable between 51 and 75 mm.
- Dioptric adjustment: On both eyepiece tubes.
- Eyepieces: WF10x/21 mm, high eye-point.
- Objective: Parfocal achromatic zoom 0.7x…4.5x (zoom factor 6.43:1).
- Working distance: 100 mm.
- Specimen stage: Gemological stage, with clamp for holding gems.
- Focusing: Rack and pinion mechanism controlled by a pair of knobs.
- Stand: Fixed arm stand with tilting system (with position lock control). It can be totally overturned and rotated allowing in this way to obtain a 2-in-one instrument: an instrument for standard observations and one for observation of water-immersed gems.
- Darkfield illumination: Equipped with a state-of-the-art illuminator for darkfield observation. It consist of an innovative side-emmiting LEDs ring with an emission angle of 38°. With brightness control.
- Transmitted light llumination: Equipped with a LED illuminator, located under the stage. With brightness control.
- Incident illumination: Equipped with a flexible gooseneck-arm LED illuminator. With brightness control.
- Color temperature: Pure white 6,300 K
Technical Specifications:
Observation Method -
Transmitted Light |
Brightfield |
Yes |
|
Darkfield |
Yes |
|
Simple polarized light |
As optional |
Observation Method -
Incident Light |
Brightfield |
Yes |
|
Darkfield |
Yes |
|
Simple polarized light |
As optional |
Main Body |
Type |
Upright |
|
Construction material |
Aluminum die-cast |
|
Trasportation handle |
Yes |
Head |
Type |
Binocular |
|
Construction material |
Aluminum & Plastic molds / Aluminum gears |
|
Inclination |
45° |
|
360° rotating |
Yes |
|
Interpupillary distance (mm) |
51-75 |
|
Dioptric adjustement |
On both tube |
|
Head holder internal diameter (mm) |
76 |
|
Tube inner diameter (mm) |
30 |
Eyepieces |
Field number (mm) |
21 |
|
Magnification |
10x |
|
Micrometric scale |
As optional |
|
Diameter of micrometer glass (mm) |
23 |
|
High eyepoint (for glass wearers) |
Yes |
|
Rubber cup |
Yes |
|
Retractable protections |
Yes |
Objectives |
Optical system |
Greenough |
|
Anti-fungus treatment |
Yes |
|
Zoom type |
Achromatic |
|
Working distance (mm) |
100 |
|
Standard magnifications |
7x-45x |
|
Zoom ratio |
6.43 |
Focusing System |
Type |
Coarse |
|
Coarse total travel (mm) |
114 |
|
Adjustable tension |
Yes |
|
Head holder internal diameter (mm) |
76 |
Stand |
Type |
Fixed arm |
|
Tilting mechanism |
Yes, full 90° tilt angle and 360° rotating |
Stage |
Gemological clamp |
Yes, adjustable |
Transmitted
Illumination |
Type |
LED |
|
Darkfield illuminator |
Yes, side-emitting LEDs |
|
Lever for dark background insertion |
Yes |
|
Selector for illumination modes |
Yes, 3 modes:
- brightfield only
- darkfield only
- both brightfield and darkfield. |
|
Light source power (W) |
2 |
|
Illuminance (lux) |
6,000 |
|
Brightness control |
Manual |
|
Lifetime (hours) |
> 65,000 |
|
Temperature (K) |
6,300 |
|
Max. required power (W) |
3 |
Incident Illumination |
Type |
LED |
|
Light source power (W) |
1 |
|
Illuminance (lux) |
20,000 |
|
Brightness control |
Manual |
|
Lifetime (hours) |
> 65,000 |
|
Temperature (K) |
6,300 |
|
Max. required power (W) |
3 |
Power Supply for
Transmitted
Illumination |
Type |
External |
|
Microscope connector |
Jack, 2.1 mm |
|
Power plug type |
Multi-plug (EU, UK, US) |
|
Input voltage |
100/240 Vac, 50/60 Hz |
|
Output voltage |
12 Vdc 2.5A |
Accessories Included |
Dust cover |
Yes |
|
User Manual |
Digital version (downloadable) |
Additional Information |
Maximum sample height (mm): |
90 |
Product Weight |
Total Height (mm) |
480 |
|
Head Height (mm) |
230 |
|
Head Width (mm) |
140 |
|
Head depth (mm) |
150 |
|
Base height (mm) |
60 |
|
Base width (mm) |
210 |
|
Base depth (mm) |
270 |
Product Weight |
(kg) |
10 |
| Fluorescence binocular and trinocular microscopes especially designed for tubercolosis and malaria analysis.
Features:
- Observation mode: Brightfield.
- Head: Trinocular, 360° rotating and 30° inclined. Interpupillary distance 48-75mm.
- Dioptric adjustement: On the left eyepiece tube.
- Eyepieces: WF10x/20 mm, high eye-point and secured by a screw.
- Nosepiece: Quadruple revolving nosepiece, rotation on ball bearings.
- Objectives:
Equipped with binocular head and following objectives:
IOS N-PLAN 10x/0.25 (Cover/No Cover), with anti-fungus treatment
IOS N-PLAN 20x/0.40 (Cover/No Cover), with anti-fungus treatment
IOS N-PLAN 40x/0.65 (Cover/No Cover), with anti-fungus treatment
IOS W-PLAN MET 50x/0.75 (No Cover), with anti-fungus treatment
- Specimen stage: Double layer rackless mechanical sliding stage, 150×139 mm, 75×33 mm X-Y movement range. Vernier scale on the two axes, accuracy: 0.1 mm.
- Focusing: Coaxial coarse and fine focusing mechanism with limit stop to prevent the contact between objective and specimen. Adjustable tension of coarse focusing knob.
- Condenser: Abbe N.A. 1.25, with objective-coded iris diaphragm, focusable and centerable.
- Brightfield Illumination (Fixed Koehler type): X-LED3 with white 3.6 W LED (6,300 K) and light intensity control. Multi-plug 100-240Vac/6Vdc external power supply.
- Fluorescence Illumination: Extra efficiency LED, with light intensity control. Peak wavelength: 465 nm, Power: 3.6W.
- Epi Fluorescence Attachment: Slider with 3 positions (2 fluorescence, 1 brightfield), with 1 included filterset: Fluorescence B: EX 460-490, DM 505, EM 515LP: Acridine Yellow, Acridine Orange, Auramine, DiO, DTAF, FITC, GFP, YFP, etc.
Technical Specifications:
Observation Method -
Transmitted Light |
Brightfield |
Yes |
|
Phase contrast (Positive type) |
As optional |
|
Darkfield |
As optional |
|
Simple polarized light |
As optional |
Observation Method -
Incident Light |
Fluorescence |
Yes |
Main Body |
Type |
Upright |
|
Construction material |
Aluminum die-cast |
|
Trasportation handle |
Yes |
Head |
Type |
Trinocular (Siedentopf) |
|
Split ratio |
50/50 |
|
Inclination |
30° |
|
360° rotating |
Yes |
|
Interpupillary distance (mm) |
48-75 |
|
Dioptric adjustement |
On left tube |
|
Fixing screw for eyepieces |
Yes |
|
Tube inner diameter (mm) |
23 |
Eyepieces |
Field number (mm) |
20 |
|
Magnification |
10x |
|
Pointer |
As optional |
|
Micrometric scale |
As optional |
|
Diameter of micrometer glass (mm) |
21 |
|
High eyepoint (for glass wearers) |
Yes |
|
Rubber cup |
Yes |
Nosepiece |
Positions |
Quadruple |
|
Bi-directional |
Yes |
|
Rotation on ball bearings |
Yes |
|
Objective thread |
RMS |
Objectives |
Optical system |
∞ |
|
Anti-fungus treatment |
Yes |
|
Parfocal distance (mm) |
45 |
|
Standard magnifications |
40x-400x |
|
Type |
IOS |
|
Objectives included |
OS N-PLAN
10x/0.25, W.D. 5.8 mm
IOS N-PLAN
20x/0.40, W.D. 5.1 mm
IOS N-PLAN
40x/0.65, W.D. 0.43 mm
IOS W-PLAN MET
50x/0.75, W.D. 0.32 mm |
Stage |
Type |
Double layer |
|
Dimensions (mm) |
150x139 |
|
Moving mechanism |
Rackless |
|
Moving range (mm) |
75x33 |
|
Material |
Anti-scratch painting |
|
Specimen holder |
Yes |
|
Slide number |
1 |
|
X-Y Vernier scale |
Yes |
|
Vernier scale accuracy (mm) |
0.1 |
Condenser - Single
Position |
Type |
Abbe |
|
Removable |
Yes |
|
Numerical aperture (N.A.) |
1.25 |
|
Magnification scale for simplified positioning |
Yes |
|
Diaphragms |
Iris |
|
Centrable |
Yes |
|
Focusable |
By rack and pinion |
Focusing System |
Type |
Coaxial coarse & fine |
|
Coarse total travel (mm) |
18 |
|
Fine total travel (per single rotation) (mm) |
0.4 |
|
Fine graduations |
100 |
|
Fine resolution (µm) |
4 |
|
Upper stop to prevent contact |
Yes |
|
Adjustable tension |
Yes |
Transmitted
Illumination |
Kohler illumination |
Fixed |
|
Type |
X-LED |
|
X-LED type |
X-LED3 |
|
Light source power (W) |
3.6 |
|
Brightness control |
Manual |
|
Lifetime (hours) |
> 65,000 |
|
Temperature (K) |
6,300 |
|
Max. required power (W) |
6 |
Power Supply for
Transmitted
Illumination |
Type |
External |
|
Microscope connector |
Jack, 2.1 mm |
|
Power plug type |
Multi-plug (EU, UK, US) |
|
Input voltage |
100/240 Vac, 50/60 Hz |
|
Output voltage |
6 Vdc 2.5A |
Accessories Included |
Dust cover |
Yes |
|
Immersion oil (10ml) |
Yes |
|
Tension adjustment tool |
Yes |
|
User Manual |
Digital version (downloadable) |
Additional Information |
|
Mirror for transmitted light (as optional).
External rechargeable battery pack (as optional) |
Product Weight |
Height (mm) |
515 |
|
Width (mm) |
235 |
|
Depth (mm) |
340 |
Product Weight |
(kg) |
7.5 |
Fluorescence
Attachment |
Number of positions |
3 |
|
Blue filter set (included) specs |
Excitation: 460 - 490 nm; Dichroic: 505 nm;
Emission: 515LP nm |
|
Filter dimensions |
Excitation: 18 mm diam.;
Dichroic: 26.5 mm x 19 mm;
Emission: 18 mm diam. |
|
Filter set selection |
Manual |
Fluorescence Light
Source |
Light source |
Blue LED |
|
Watt (W) |
3.6 |
|
LED wavelength |
Blue LED: 465 nm |
|
Lifetime (hours) |
> 65,000 |
|
Brightness control |
Yes |
| The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts.
Technical specifications:
- Speed: 11,800rpm with 24- place rotor
- RCF: 14,000g with 24-place rotor
- Acceleration: 0-11,800rpm in 60 seconds, with 24-place rotor
- Brake: Automatic
- Noise: 62dB running with 24-place rotor
- Motor: High precision AC/DC series wound motor, brush gear, computer wound coil winding, balance armature and high speed bearings.
- Timer: 0-15 minute timer, graduated in 1 minute increments. Automatic switch at zero
- Weight: 5.1Kg net (without rotor)
- Dimensions: 23.5cm height x 27cm diameter, footprint 16cm diameter
- Construction: Aluminium casing with a steel lid
- Finish: Body cream white baked enamel, with matt black baked enamel lid
| Cordless, modern binocular microscope ideal for students and mainly primary schools with achromatic lenses (1000x), FN 18 eyepieces, finite optical system, coaxial focusing, StagErase™ eraseable mechanical stage, Abbe condenser and 1 W LED illumination with rechargeable batteries. Slim and easy to carry, it is equipped with arm/wrist rest support to reduce the fatigue during use and long lasting LED illumination to provide over 20 years of use.
Features:
- Observation mode: Brightfield.
- Head: Binocular, 30° inclined; 360° rotating.
- Dioptric adjustment: Left eyepiece.
- Eyepiece: WF10x/18 mm, secured by screw
- Nosepiece: Quadruple ball bearings revolving nosepiece, reversed.
- Objectives:
– Achromatic 4x/0.10, with anti-fungus treatment
– Achromatic 10x/0.25, with anti-fungus treatment
– Achromatic 40x/0.65, with anti-fungus treatment
– Achromatic 100x/1.25 (oil), with anti-fungus treatment
- Specimen stage: StagErase™ eraseable mechanical stage, 125×125 mm, 62×24 mm X-Y movement range. Vernier scale on the two axes, accuracy: 0.1 mm.
- Focusing: Coaxial coarse and fine focusing mechanism with limit stop to prevent the contact between objective and specimen.
- Condenser: Abbe N.A. 1.25, pre-centered, focusable, with iris diaphragm.
- Illumination: 1 W LED, with brightness control, rechargeable batteries.
- Color temperature: 6,300 K. Multi-plug 100-240Vac/5Vdc external power supply.
Technical Specifications:
Observation Method - Transmitted Light |
Brightfield |
Yes |
|
Simple polarized light |
As optional |
Main Body |
Type |
Upright |
|
Construction material |
Aluminum die-cast |
|
Trasportation handle |
Yes |
Head |
Type |
Binocular (Siedentopf) |
|
Inclination |
30° |
|
360° rotating |
Yes |
|
Interpupillary distance (mm) |
55-75 |
|
Dioptric adjustement |
On left tube |
|
Fixing screw for eyepieces |
Yes |
|
Tube inner diameter (mm) |
23 |
Eyepieces |
Field number (mm) |
18 |
|
Magnification |
10x |
|
Pointer |
As optional |
|
Micrometric scale |
As optional |
Nosepiece |
Positions |
Quadruple |
|
Reversed |
Yes |
|
Bi-directional |
Yes |
|
Rotation on ball bearings |
Yes |
|
Objective thread |
RMS |
Objectives |
Optical system |
160 |
|
Anti-fungus treatment |
Yes |
|
Parfocal distance (mm) |
35 |
|
Standard magnifications |
40x-1000x |
|
Type |
Achromatic |
|
|
4x/0.10, W.D. 10.6 mm |
|
|
10x/0.25, W.D. 7.0 mm |
|
|
40x/0.65, W.D. 0.5 mm |
|
|
100x/1.25 (Oil), W.D. 0.13 mm |
Stage |
Type |
Double layer |
|
Dimensions (mm) |
125x125 |
|
Moving mechanism |
Rack and pinion |
|
Moving range (mm) |
62x24 |
|
Material |
Anti-scratch painting |
|
Specimen holder |
Yes |
|
Slide number |
1 |
|
X-Y Vernier scale |
Yes |
|
Vernier scale accuracy (mm) |
0.1 |
Condenser - Single
Position |
Type |
Abbe |
|
Numerical aperture (N.A.) |
1.25 |
|
Diaphragms |
Iris |
|
Focusable |
By rotation |
Focusing System |
Type |
Coaxial coarse & fine |
|
Coarse total travel (mm) |
23 |
|
Fine total travel (per single rotation) (mm) |
1.2 |
|
Fine graduations |
100 |
|
Fine resolution (µm) |
12 |
|
Upper stop to prevent contact |
Yes |
Transmitted
Illumination |
Type |
LED |
|
Light source power (W) |
1 |
|
Brightness control |
Manual |
|
Lifetime (hours) |
> 65,000 |
|
Temperature (K) |
6,300 |
|
Max. required power (W) |
1.5 |
Power Supply for
Transmitted
Illumination |
Type |
External |
|
Microscope connector |
Jack, 2.1 mm |
|
Power plug type |
Multi-plug (EU, UK, US) |
|
Input voltage |
100/240 Vac, 50/60 Hz |
|
Output voltage |
5 Vdc 500 mA |
|
Rechargeable batteries |
Yes |
|
Battery type |
Ni-MH (3x, AAA size) |
|
Working time of batteries (hours) |
4 |
|
Charging time of batteries (hours) |
8 |
Accessories Included |
Dust cover |
Yes |
|
Immersion oil (10ml) |
Yes |
|
User Manual |
Digital version (downloadable) |
Product Dimensions |
Height (mm) |
330 |
|
Width (mm) |
135 |
|
Depth (mm) |
235 |
Product Weight |
(kg) |
3.0 |
| Phase contrast, darkfield and brightfield binocular microscope with W-PLAN objectives, rackless stage and combining the exclusive X-LED3 with ALC (Automatic Light Control) for great-looking, rich and highquality view.
Features:
- Observation mode: Brightfield, phase contrast and darkfield (dry).
- Head: Binocular, 30° inclined, 360° rotating (when ALC cable is unplugged).
- Interpupillary distance: Adjustable between 48 and 75 mm.
- Dioptric adjustment: On the left eyepiece tube.
- Eyepieces: WF10x/20 mm, high eye-point and secured by screw.
- Nosepiece: Quintuple revolving nosepiece, rotation on ball bearings.
- Objectives:
W-PLAN 4x/0.10
W-PLAN PH 10x/0.25
W-PLAN PH 40x/0.65
W-PLAN PH 100x/1.25 (Oil/Water)
All with anti-fungus treatment.
- Specimen stage: Double layer rackless mechanical stage, 150×139 mm, 75×33 mm X-Y range.
- Focusing: Coaxial coarse (adjustable tension) and fine focusing mechanism with limit stop to prevent the contact between objective and specimen.
- Condenser: Phase condenser (10x/20x, 40x, 100x) with darkfield (dry) and brightfield.
- Illumination (Fixed Koehler type): X-LED3 with white 3.6 W LED (6,300K) and brightness control. ALC system. Multi-plug 100-240Vac/6Vdc external power supply
Technical Specifications:
Observation Method -
Transmitted Light |
Brightfield |
Yes |
|
Phase contrast (Positive type) |
Yes |
|
Darkfield |
Yes |
|
Simple polarized light |
As optional |
Main Body |
Type |
Upright |
|
Construction material |
Aluminum die-cast |
|
Trasportation handle |
Yes |
Head |
Type |
Binocular (Siedentopf) |
|
Inclination |
30° |
|
360° rotating |
Yes |
|
Interpupillary distance (mm) |
48-75 |
|
Dioptric adjustement |
On left tube |
|
Fixing screw for eyepieces |
Yes |
|
Tube inner diameter (mm) |
23 |
Eyepieces |
Field number (mm) |
20 |
|
Magnification |
10x |
|
Pointer |
As optional |
|
Micrometric scale |
As optional |
|
Diameter of micrometer glass (mm) |
21 |
|
High eyepoint (for glass wearers) |
Yes |
|
Rubber cup |
Yes |
Nosepiece |
Positions |
Quintuple |
|
Reversed |
Yes |
|
Bi-directional |
Yes |
|
Rotation on ball bearings |
Yes |
|
Objective thread |
RMS |
Objectives |
Optical system |
160 |
|
Anti-fungus treatment |
Yes |
|
Parfocal distance (mm) |
45 |
|
Standard magnifications |
40x-1000x |
|
Type |
IOS |
|
|
W-PLAN
4x/0.10, W.D. 15.8 mm
W-PLAN PH
10x/0.25, W.D. 12.2 mm
W-PLAN PH
40x/0.65, W.D. 0.37 mm
W-PLAN PH
100x/1.25 (Oil),
W.D. 0.13 mm |
Stage |
Type |
Double layer |
|
Dimensions (mm) |
150x139 |
|
Moving mechanism |
Rackless |
|
Moving range (mm) |
75x33 |
|
Material |
Anti-scratch painting |
|
Specimen holder |
Yes |
|
Slide number |
1 |
|
X-Y Vernier scale |
Yes |
|
Vernier scale accuracy (mm) |
0.1 |
Condenser - Multiple
Position |
Type |
Abbe.
Brightfield - Phase contrast - Darkfield (dry) |
|
Number of positions |
5 (BF, 10x/20x, 40x, 100x, DF) |
|
Numerical aperture (N.A.) |
1.25 |
|
Removable |
Yes |
|
Diaphragms |
Iris |
|
Centrable |
Yes |
|
Focusable |
By rack and pinion |
Focusing System |
Type |
Coaxial coarse & fine |
|
Coarse total travel (mm) |
25 |
|
Fine total travel (per single rotation) (mm) |
0.2 |
|
Fine graduations |
100 |
|
Fine resolution (µm) |
2 |
|
Upper stop to prevent contact |
Yes |
|
Adjustable tension |
Yes |
|
Flat knob for ergonomy |
Yes |
Transmitted
Illumination |
Kohler illumination |
Fixed (full as optional) |
|
Type |
X-LED |
|
X-LED type |
X-LED3 |
|
Light source power (W) |
3.6 |
|
Brightness control |
Manual
& Automatic (ALC) |
|
Lifetime (hours) |
> 65,000 |
|
Temperature (K) |
6,300 |
|
Max. required power (W) |
6 |
Power Supply for
Transmitted
Illumination |
Type |
External |
|
Microscope connector |
Jack, 2.1 mm |
|
Power plug type |
Multi-plug (EU, UK, US) |
|
Input voltage |
100/240 Vac, 50/60 Hz |
|
Output voltage |
6 Vdc 2.5A |
Accessories Included |
Dust cover |
Yes |
|
Immersion oil (10ml) |
Yes |
|
Tension adjustment tool |
Yes |
|
Allen wrench |
Yes |
|
Centering telescope |
Yes |
|
Green filter |
Yes |
|
User Manual |
Digital version (downloadable) |
Additional Information |
|
External rechargeable battery pack (as optional) |
Product Weight |
Height (mm) |
405 |
|
Width (mm) |
235 |
|
Depth (mm) |
370 |
Product Weight |
(kg) |
8 |
|
Reviews
There are no reviews yet.