Description | Shipped From Abroad
The M-240 microtome from Myr uses state-of-the-art technology and embodies the our commitment to quality and excellence in the microtomy. It provides the operational convenience and the stability required for outstanding sectioning in routine, research and industry applications.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from Abroad
Cordless binocular microscope ideal for students and primary schools, with four PLAN achromatic lenses (1000x), FN 18 high eyepointeyepieces, finite optical system, coaxial focusing, mechanical stage, Abbe condenser and powerful, uniform, white color temperature 1 W X-LED1 illumination.
Delivery & Availability:
Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad
Fluorescence binocular and trinocular microscopes especially designed for tubercolosis and malaria analysis.
Delivery & Availability:
Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
Needle destruction destroy the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad
Digital binocular microscope ideal for teachers and secondary schools, with four achromatic lenses (1000x), FN 18 high eyepoint, finite optical system, coaxial focusing, mechanical stage, Abbe condenser and powerful, uniform, white color temperature 3 W X-LED2 illumination.
Delivery & Availability:
Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad
OPTIKA polarizing microscopes offer a complete system for your laboratory analysis, including polarizer and analyzer filters, Bertrand lens for conoscopic observation, compensator plates, and high-precision rotatable stages. Also available the X-LED illumination system, a high-intensity light source that delivers bright and clear images.
Delivery & Availability:
Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
Content | Features
Full color TFT 7” display with PCAD (projected capacitive) touchscreen. Size and tilt of the display allow an easy and effortless selection of the parameters and increase user safety.
All required parameters and functions are available on the main screen: section mode, section and trimming thickness, section counter, section sum, remaining travel, retraction and coarse feed, memory function.
MEM key for higher productivity, to retrieve previous cuttings settings when working with uniform paraffin blocks. By simply pressing a key, the specimen moves into the stored MEM position.
Thanks to a blocking mechanism the easy to operate change system allows to work with different specimen clamps. Indication of 0-position in x and y direction by palpable “click” for the precise alignment of the specimen.
Precise, motorized coarse feed in two modes, continuous and step. In continuous mode, speed is selectable between slow and fast to ensure a controlled specimen approach.
- Quick release specimen clamp
Cutting-edge design of the specimen clamp that prevents building up of dirt and facilitates operations with the microtome. The retraction function selectable between 5 -250μ can be deactivated, although it is advisable as it prolongs the life of the blade. ( Default value 40 μ)
Special antistatic coating prevents paraffin adhesion and minimizes the cleaning time. Ergonomic design with surface for arm rest. Wide area on the top of the microtome for the storage of tools.
Blade holder slides sideways in both directions allowing the use of the entire cutting edge. It accepts low- and high-profile blades. All blade holders are equipped with finger guard for safety reasons.
- Smooth and ergonomic handwheel
The handwheel is perfectly balanced thanks to an innovating counterweight system and can be locked in any angular position. Cutting can be done by turning the handwheel clockwise or counterclockwise.
Technical Data Microtome M-240
Section thickness |
|
Total range in (μm) |
0,5 – 100 |
Thickness settings in (μm) |
|
|
0,5 – 5 in increments of 0,5 |
|
5 – 20 in increments of 1 |
|
20 – 60 in increments of 5 |
|
60 – 100 in increments of 10 |
Trimming |
|
Total range in (μm) |
1 – 600 |
Thickness settings in (μm) |
|
|
1 – 10 in increments of 1 |
|
10 – 20 in increments of 2 |
|
20 – 50 in increments of 5 |
|
50 – 100 in increments of 10 |
|
100 – 600 in increments of 50 |
Specimen feed (mm) |
28 ± 1 mm |
Vertical stroke (mm) |
72 ± 1 mm to allow sectioning of mega-cassettes |
User interface |
7” capacitive touchscreen display |
Operating modes |
Rotational or Rocking (selectable) |
Specimen retraction |
Optional function that can be deactivated |
Total range in (μm) |
5 – 250 μm (selectable in 1 μm increment) |
|
5 predefined values: 20, 30, 40, 60, 80 μm |
|
Default value: 40 μm |
Motorized coarse feed (μm/sec) |
|
|
300 (slow speed forward) |
|
800 (fast speed forward) |
|
1800 (ultrafast speed backward) |
|
Additional function for forward/backward coarse feed in step mode |
Blade Holder Type |
Two in One for high- and low-profile blades |
Max. specimen size |
50x60x40 mm (w x h x d)
Super cassette clamp 68x48x15 mm |
Specimen orientation |
|
|
± 8º horizontal and vertical |
|
Rotational capability: 360º |
|
Indication of 0-position by means of click (x and y direction) |
Power requirements |
100-240 VAC / 50-60Hz |
Consumption |
40 VA |
Dimensions |
|
Width |
465 mm |
Depth with tray |
540 mm |
Height |
298 mm |
Weight |
33,9 kg |
| Cordless binocular microscope ideal for students and primary schools, with four PLAN achromatic lenses (1000x), FN 18 high eyepointeyepieces, finite optical system, coaxial focusing, mechanical stage, Abbe condenser and powerful, uniform, white color temperature 1 W X-LED1 illumination. Slim and easy to carry, it is equipped with all the main controls to start learning how to use an advanced microscope and with long lasting LED illumination to provide over 20 years of use. The exclusive Li-Ion battery ensures unparalleled duration and fast recharge.
Features:
- Observation mode: Brightfield.
- Head: Binocular, 30° inclined; 360° rotating.
- Eyepieces: WF10x/18 mm, secured by screw.
- Nosepiece: Quadruple ball bearings revolving nosepiece.
- Objectives:
– N-PLAN 4x/0.10 , with anti-fungus treatment
– N-PLAN 10x/0.25 , with anti-fungus treatment
– N-PLAN 40x/0.65 , with anti-fungus treatment
– N-PLAN 100x/1.25 (Oil/Water) , with anti-fungus treatment
- Specimen stage: Mechanical stage, 125x116mm, 70×30 mm X-Y movement range. Vernier scale on the two axes, accuracy: 0.1mm.
- Focusing: Coaxial coarse and fine focusing mechanism with limit stop to prevent the contact between objective and specimen. Adjustable tension of coarse focusing knob.
- Condenser: Abbe N.A. 1.25, pre-centered, focusable, with iris diaphragm.
- Illumination: X-LED1 with white 1 W LED and light intensity control.
- Color temperature: 6,300 K. Li-Ion battery for long lasting operation. Multi-plug 100-240Vac/5Vdc external power supply.
Technical Specifications:
Observation Method -
Transmitted Light |
Brightfield |
Yes |
|
Simple polarized light |
As optional |
Main Body |
Type |
Upright |
|
Construction material |
Aluminum die-cast |
Head |
Type |
Binocular (Siedentopf) |
|
Inclination |
30° |
|
360° rotating |
Yes |
|
Interpupillary distance (mm) |
48-75 |
|
Dioptric adjustement |
On left tube |
|
Fixing screw for eyepieces |
Yes |
|
Tube inner diameter (mm) |
23 |
Eyepieces |
Field number (mm) |
18 |
|
Magnification |
10x |
|
High eyepoint (for glass wearers) |
Yes |
|
Pointer |
As optional |
|
Micrometric scale |
As optional |
|
Diameter of micrometer glass (mm) |
20 |
Nosepiece |
Positions |
Quadruple |
|
Bi-directional |
Yes |
|
Rotation on ball bearings |
Yes |
|
Objective thread |
RMS |
Objectives |
Optical system |
160 |
|
Anti-fungus treatment |
Yes |
|
Parfocal distance (mm) |
45 |
|
Standard magnifications |
40x-400x |
|
Type |
N-PLAN |
|
Objectives included |
4x/0.10, W.D. 15.2 mm
10x/0.25, W.D. 5.5 mm
40x/0.65, W.D. 0.45 mm |
|
|
100x/1.25 (Oil/Water)
W.D. 0.13 mm |
Stage |
Type |
Double layer |
|
Dimensions (mm) |
125x116 |
|
Moving mechanism |
Rack and pinion |
|
Moving range (mm) |
70x30 |
|
Material |
Anti-scratch painting |
|
Specimen clips |
Yes |
|
Slide number |
1 |
|
X-Y Vernier scale |
Yes |
|
Vernier scale accuracy (mm) |
0.1 |
Condenser - Single
Position |
Type |
Abbe |
|
Numerical aperture (N.A.) |
1.25 |
|
Diaphragms |
Iris |
|
Centrable |
Pre-centered |
|
Focusable |
By rotation |
Focusing System |
Type |
Coaxial coarse & fine |
|
Coarse total travel (mm) |
16 |
|
Fine total travel (per single rotation) (mm) |
0.4 |
|
Fine graduations |
100 |
|
Fine resolution (µm) |
4 |
|
Upper stop to prevent contact |
Yes |
|
Adjustable tension |
Yes |
Transmitted
Illumination |
Type |
X-LED |
|
X-LED type |
X-LED1 |
|
Light source power (W) |
1 |
|
Brightness control |
Manual |
|
Lifetime (hours) |
> 65,000 |
|
Temperature (K) |
6,300 |
|
Max. required power (W) |
1.5 |
Power Supply for
Transmitted
Illumination |
Type |
External |
|
Microscope connector |
Jack, 2.1 mm |
|
Power plug type |
Multi-plug (EU, UK, US) |
|
Input voltage |
100/240 Vac, 50/60 Hz |
|
Output voltage |
5 Vdc 500 mA |
|
LED indicator |
Yes |
|
Rechargeable batteries |
Yes |
|
Battery type |
Li-ion (battery pack) |
|
Working time of batteries (hours) |
15 |
|
Charging time of batteries (hours) |
6 |
Accessories Included |
Dust cover |
Yes |
|
Immersion oil (10ml) |
Yes |
|
Tension adjustment tool |
Yes |
|
User Manual |
Digital version (downloadable) |
Additional Information |
|
Mirror for transmitted light (as optional) |
Product Weight |
Height (mm) |
350 |
|
Width (mm) |
170 |
|
Depth (mm) |
320 |
Product Weight |
(kg) |
4 |
| Fluorescence binocular and trinocular microscopes especially designed for tubercolosis and malaria analysis.
Features:
- Observation mode: Brightfield.
- Head: Trinocular, 360° rotating and 30° inclined. Interpupillary distance 48-75mm.
- Dioptric adjustement: On the left eyepiece tube.
- Eyepieces: WF10x/20 mm, high eye-point and secured by a screw.
- Nosepiece: Quadruple revolving nosepiece, rotation on ball bearings.
- Objectives:
Equipped with binocular head and following objectives:
IOS N-PLAN 10x/0.25 (Cover/No Cover), with anti-fungus treatment
IOS N-PLAN 20x/0.40 (Cover/No Cover), with anti-fungus treatment
IOS N-PLAN 40x/0.65 (Cover/No Cover), with anti-fungus treatment
IOS W-PLAN MET 50x/0.75 (No Cover), with anti-fungus treatment
- Specimen stage: Double layer rackless mechanical sliding stage, 150×139 mm, 75×33 mm X-Y movement range. Vernier scale on the two axes, accuracy: 0.1 mm.
- Focusing: Coaxial coarse and fine focusing mechanism with limit stop to prevent the contact between objective and specimen. Adjustable tension of coarse focusing knob.
- Condenser: Abbe N.A. 1.25, with objective-coded iris diaphragm, focusable and centerable.
- Brightfield Illumination (Fixed Koehler type): X-LED3 with white 3.6 W LED (6,300 K) and light intensity control. Multi-plug 100-240Vac/6Vdc external power supply.
- Fluorescence Illumination: Extra efficiency LED, with light intensity control. Peak wavelength: 465 nm, Power: 3.6W.
- Epi Fluorescence Attachment: Slider with 3 positions (2 fluorescence, 1 brightfield), with 1 included filterset: Fluorescence B: EX 460-490, DM 505, EM 515LP: Acridine Yellow, Acridine Orange, Auramine, DiO, DTAF, FITC, GFP, YFP, etc.
Technical Specifications:
Observation Method -
Transmitted Light |
Brightfield |
Yes |
|
Phase contrast (Positive type) |
As optional |
|
Darkfield |
As optional |
|
Simple polarized light |
As optional |
Observation Method -
Incident Light |
Fluorescence |
Yes |
Main Body |
Type |
Upright |
|
Construction material |
Aluminum die-cast |
|
Trasportation handle |
Yes |
Head |
Type |
Trinocular (Siedentopf) |
|
Split ratio |
50/50 |
|
Inclination |
30° |
|
360° rotating |
Yes |
|
Interpupillary distance (mm) |
48-75 |
|
Dioptric adjustement |
On left tube |
|
Fixing screw for eyepieces |
Yes |
|
Tube inner diameter (mm) |
23 |
Eyepieces |
Field number (mm) |
20 |
|
Magnification |
10x |
|
Pointer |
As optional |
|
Micrometric scale |
As optional |
|
Diameter of micrometer glass (mm) |
21 |
|
High eyepoint (for glass wearers) |
Yes |
|
Rubber cup |
Yes |
Nosepiece |
Positions |
Quadruple |
|
Bi-directional |
Yes |
|
Rotation on ball bearings |
Yes |
|
Objective thread |
RMS |
Objectives |
Optical system |
∞ |
|
Anti-fungus treatment |
Yes |
|
Parfocal distance (mm) |
45 |
|
Standard magnifications |
40x-400x |
|
Type |
IOS |
|
Objectives included |
OS N-PLAN
10x/0.25, W.D. 5.8 mm
IOS N-PLAN
20x/0.40, W.D. 5.1 mm
IOS N-PLAN
40x/0.65, W.D. 0.43 mm
IOS W-PLAN MET
50x/0.75, W.D. 0.32 mm |
Stage |
Type |
Double layer |
|
Dimensions (mm) |
150x139 |
|
Moving mechanism |
Rackless |
|
Moving range (mm) |
75x33 |
|
Material |
Anti-scratch painting |
|
Specimen holder |
Yes |
|
Slide number |
1 |
|
X-Y Vernier scale |
Yes |
|
Vernier scale accuracy (mm) |
0.1 |
Condenser - Single
Position |
Type |
Abbe |
|
Removable |
Yes |
|
Numerical aperture (N.A.) |
1.25 |
|
Magnification scale for simplified positioning |
Yes |
|
Diaphragms |
Iris |
|
Centrable |
Yes |
|
Focusable |
By rack and pinion |
Focusing System |
Type |
Coaxial coarse & fine |
|
Coarse total travel (mm) |
18 |
|
Fine total travel (per single rotation) (mm) |
0.4 |
|
Fine graduations |
100 |
|
Fine resolution (µm) |
4 |
|
Upper stop to prevent contact |
Yes |
|
Adjustable tension |
Yes |
Transmitted
Illumination |
Kohler illumination |
Fixed |
|
Type |
X-LED |
|
X-LED type |
X-LED3 |
|
Light source power (W) |
3.6 |
|
Brightness control |
Manual |
|
Lifetime (hours) |
> 65,000 |
|
Temperature (K) |
6,300 |
|
Max. required power (W) |
6 |
Power Supply for
Transmitted
Illumination |
Type |
External |
|
Microscope connector |
Jack, 2.1 mm |
|
Power plug type |
Multi-plug (EU, UK, US) |
|
Input voltage |
100/240 Vac, 50/60 Hz |
|
Output voltage |
6 Vdc 2.5A |
Accessories Included |
Dust cover |
Yes |
|
Immersion oil (10ml) |
Yes |
|
Tension adjustment tool |
Yes |
|
User Manual |
Digital version (downloadable) |
Additional Information |
|
Mirror for transmitted light (as optional).
External rechargeable battery pack (as optional) |
Product Weight |
Height (mm) |
515 |
|
Width (mm) |
235 |
|
Depth (mm) |
340 |
Product Weight |
(kg) |
7.5 |
Fluorescence
Attachment |
Number of positions |
3 |
|
Blue filter set (included) specs |
Excitation: 460 - 490 nm; Dichroic: 505 nm;
Emission: 515LP nm |
|
Filter dimensions |
Excitation: 18 mm diam.;
Dichroic: 26.5 mm x 19 mm;
Emission: 18 mm diam. |
|
Filter set selection |
Manual |
Fluorescence Light
Source |
Light source |
Blue LED |
|
Watt (W) |
3.6 |
|
LED wavelength |
Blue LED: 465 nm |
|
Lifetime (hours) |
> 65,000 |
|
Brightness control |
Yes |
| Needle destruction destroys the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle.
Features:
- Well built
- Easy to maintain
- Having a rubbish drawer with alarm function, this is our most popular model of Syringe Destroyer for use in labs, pharma, universities and doctors clinics
- With its low factory-direct price and excellent quality, its a great addition to add to any medical industry or university office that wants to ensure the safety and legal compliance of its operations
Specifications:
- Short Name: Needle destruction / Needle Destroyer
- Working Noise: ≤50 decibel
- Superheating Sanitization Temperature: 95 deg C
- Working Time: Can completely melt and destroy needle and neck of syringe in 5 seconds
- Working Noise: ≤50 decibel
- Dimensions: Approx. 38cm x 29cm x 28cm
- Power: AC 110V or 220V
| Digital binocular microscope ideal for teachers and secondary schools, with four achromatic lenses (1000x), FN 18 high eyepoint, finite optical system, coaxial focusing, mechanical stage, Abbe condenser and powerful, uniform, white color temperature 3 W X-LED2 illumination. The 3.1 MP CMOS camera ensures excellent colour reproduction and is connected to a Windows tablet PC with vivid color graphic display for unparalleled comfort and performance. The tablet represents a 2-in-1 solution as it can be disconnected and used as a real PC, being Windowsbased, with powerful Intel processor and large touch screen of 10.1” for fast, responsive and smooth control.
Features:
- Observation mode: Brightfield.
- Head: Binocular, 360° rotating and 30° inclined. Interpupillary distance from 48 to 75 mm; dioptric adjuctment on left eyepiece. Built-in 3.1 MP camera.
- Eyepieces: WF 10x/18 mm, secured by screw.
- Nosepiece: Quadruple revolving nosepiece, rotation on ball bearings.
- Objectives:
HC – High Contrast Achromatic 4x/0.10 with anti-fungus treatment.
HC – High Contrast Achromatic 10x/0.25 with anti-fungus treatment.
HC – High Contrast Achromatic 40x/0.65 with anti-fungus treatment.
HC – High Contrast Achromatic 100x/1.25 (Oil/Water) with anti-fungus treatment.
- Specimen stage: Double layer mechanical sliding stage, 125×115 mm, 70×30 mm X-Y movement range. Vernier scale on the two axes, accuracy: 0.1mm.
- Focusing: Coaxial coarse (adjustable tension) and fine focusing mechanism with limit stop to prevent the contact between objective and specimen.
- Condenser: Abbe N.A. 1.25, pre-centered, adjustable height with iris diaphragm.
- Illumination: X-LED² with white 3 W LED and light intensity control. Color temperature: 6,300 K. Multi-plug 100-240Vac/6Vdc external power supply. Color temperature: 6,300 K.
Technical Specifications:
Observation Method -
Transmitted Light |
Brightfield |
Yes |
|
Simple polarized light |
As optional |
Main Body |
Type |
Upright |
|
Construction material |
Aluminum die-cast |
|
Trasportation handle |
Yes |
Head |
Type |
Binocular (Siedentopf) |
|
Inclination |
30° |
|
360° rotating |
Yes |
|
Interpupillary distance (mm) |
48-75 |
|
Dioptric adjustement |
On left tube |
|
Fixing screw for eyepieces |
Yes |
|
Tube inner diameter (mm) |
23 |
Eyepieces |
Field number (mm) |
18 |
|
Magnification |
10x |
|
Pointer |
As optional |
|
Micrometric scale |
As optional |
|
Diameter of micrometer glass (mm) |
20 |
|
High eyepoint (for glass wearers) |
Yes |
Nosepiece |
Positions |
Quadruple |
|
Bi-directional |
Yes |
|
Rotation on ball bearings |
Yes |
|
Objective thread |
RMS |
Objectives |
Optical system |
160 |
|
Anti-fungus treatment |
Yes |
|
Parfocal distance (mm) |
45 |
|
Standard magnifications |
40x-400x |
|
Type |
HC |
|
Objectives included |
4x/0.10, W.D. 18 mm
10x/0.25, W.D. 7 mm
40x/0.65, W.D. 0.53 mm |
|
|
100x/1.25 (Oil/Water)
W.D. 0.13 mm |
Stage |
Type |
Double layer |
|
Dimensions (mm) |
125x116 |
|
Moving mechanism |
Rack and pinion |
|
Moving range (mm) |
70x30 |
|
Material |
Anti-scratch painting |
|
Specimen clips |
Yes |
|
Slide number |
1 |
|
X-Y movement |
Yes |
|
X-Y Vernier scale |
Yes |
|
Vernier scale accuracy (mm) |
0.1 |
Condenser - Single
Position |
Type |
Abbe |
|
Numerical aperture (N.A.) |
1.25 |
|
Centrable |
Pre-centered |
|
Focusable |
By rotation |
Focusing System |
Type |
Coaxial coarse & fine |
|
Coarse total travel (mm) |
18 |
|
Fine total travel (per single rotation) (mm) |
0.4 |
|
Fine graduations |
100 |
|
Fine resolution (µm) |
4 |
|
Upper stop to prevent contact |
Yes |
|
Adjustable tension |
Yes |
Transmitted
Illumination |
Type |
X-LED |
|
X-LED type |
X-LED2 |
|
Light source power (W) |
3 |
|
Brightness control |
Manual |
|
Lifetime (hours) |
> 65,000 |
|
Temperature (K) |
6,300 |
|
Max. required power (W) |
6 |
Power Supply for
Transmitted
Illumination |
Type |
External |
|
Microscope connector |
Jack, 2.1 mm |
|
Power plug type |
Multi-plug (EU, UK, US) |
|
Input voltage |
100/240 Vac, 50/60 Hz |
|
Output voltage |
6 Vdc 2.5A |
Accessories Included |
Dust cover |
Yes |
|
Immersion oil (10ml) |
Yes |
|
Tension adjustment tool |
Yes |
|
User Manual |
Digital version (downloadable) |
|
Calibration slide |
Yes |
|
Touch pen |
Yes |
|
USB cable (m) |
0.5 |
Additional Information |
|
External rechargeable battery pack (as optional).
Tablet Keyboard (as optional). |
Product Weight |
Height (mm) |
525 |
|
Width (mm) |
260 |
|
Depth (mm) |
320 |
Product Weight |
(kg) |
7.5 |
Camera specifications |
PC Camera resolution (MP) |
3.1 |
|
Camera resolution (n° of pixels: W x H) |
2048x1536 |
|
USB Signal output |
USB 2.0 |
|
Color / Monochrome |
Color |
|
Sensor Size |
1/2.5" |
|
Sensor Technology |
CMOS |
|
Sensor Type |
APTINA CMOS |
|
Rolling Shutter |
Yes |
|
Image Format |
4/3 |
|
Pixel Size (mm) |
2.2x2.2 |
|
Frame rate full resolution (fps) |
8@1280x1024 |
|
Frame rate other resolution (fps) |
30@640x480 |
|
Sensitivity |
0.53 V/lux-second |
|
Signal/Noise Ratio (DB) |
40.5 |
|
Dynamic range (DB) |
66.5 |
|
ADC conversion |
12 Bit |
|
Color Depth |
8 Bit |
|
Exposure time |
… - 1.5 sec |
|
Binning |
1x1 |
|
IR filter |
Yes |
|
IR filter range (nm) |
680 |
|
Camera Power |
PC USB |
|
C-Mount |
Yes |
Camera accessories |
Calibration slide |
Yes |
Environment
specifications |
Working Temperature |
-10°C up to +50°C |
|
Storage Temperature |
-20°C up to +60°C |
|
Relative Humidity |
30% to 80% |
|
Storage Humidity |
10% to 60% |
Operating System |
OS |
Windows 10 (64Bit) |
Available Software |
SW |
PROVIEW |
Warranty |
Years |
2 |
Tablet |
Operating system |
Windows 10 (64Bit) |
|
CPU |
Intel® Atom™ Z8350, Quad core |
|
CPU speed |
1.44 GHz |
|
Graphic card |
Intel® HD Graphics 400 |
|
RAM |
Ram 4 GB LPDDR3 |
|
Display size |
LED 10.1” IPS Multi Touch Screen |
|
Display resolution |
1920x1200 |
|
Storage |
Hdd 64 GB |
|
Network |
Wireless - Bluetooth 4.0 |
|
Input ports |
Micro USB (OTG) - USB Type-C - Micro SD card
reader |
|
Output ports |
Microphone - Headphone - Micro HDMI |
|
Battery Type |
Lithium-ion |
|
Battery capacity |
6500 mAh |
|
Power consumption |
15W |
|
Power supply |
5V 3A |
|
Dimensions (mm) |
261X167X9 |
|
Weight (Kg) |
0.53 |
|
Language |
Multilanguage |
Tablet accessories |
OTG cable (micro USB-B to USB-A) |
Yes |
|
USB cable USB-B to USB-A (0.5m) |
Yes |
|
Touch pen |
Yes |
| Observation mode: Brightfield, transmitted polarized light and conoscopy.
Bertrand lens and polarizing attachment: Swing-out type with centering mechanism for observation in conoscopy/orthoscopy. Rotatable analyzer from 0° to 90° with graduated scale. Tint plates: 1° order red (λ); λ/4; Quartz wedge.
Head: Trinocular (fixed 50/50), 30° inclined, 360° rotating.
Interpupillary distance: Adjustable between 48 and 75 mm.
Dioptric adjustment: On the left eyepiece tube.
Eyepieces: WF10x/20 mm, high eye-point and secured by screw. One with crosshair.
Nosepiece: Quadruple revolving nosepiece, rotation on ball bearings. Centering system for each objective.
Objectives (strain-free):
IOS N-PLAN POL 4x/0.10
IOS N-PLAN POL 10x/0.25
IOS N-PLAN POL 40x/0.65
IOS N-PLAN POL 60x/0.80
All with anti-fungus treatment.
Specimen stage: Rotatable stage with locking mechanism. Vernier scale with accuracy 0.1 mm. Diameter 160 mm. Specimen slide clamps.
Focusing: Coaxial coarse (adjustable tension) and fine focusing mechanism with limit stop to prevent the contact between objective and specimen.
Condenser: Abbe N.A. 1.25, with objective-coded iris diaphragm, focusable and centerable. With rotating polarizing filter.
Transmitted illumination (Fixed Koehler type): X-LED3 with white 3.6 W LED (6.300 K) with brightness control. Multi-plug 100-240Vac/6Vdc external power supply.
Specifications |
Head |
Trinocular, 30° inclined, 360° rotating. |
Eyepiece |
WF10x/20mm and with cross-hair micrometer |
Bertrand lens |
Swing-out type; center-able. |
Polarizing attachment |
0° – 90° rotating analyzing filter. Tint plates included: 1° order red (lambda), lambda/4, quartz wedge. |
Nosepiece |
Quadruple, reversed |
Objectives |
IOS N-PLAN POL 4x, 10x, 40x, 60x
View Optika Objective Brochure |
Focusing system |
Coaxial coarse and fine |
Stage |
Round, 360° rotating, 160 mm diameter, with sample clips and stop knob |
Condenser |
Abbe N.A. 1.25, iris diaphragm, focusable and centrable. With rotating polarizer |
Illumination |
X-LED3 illumination system with brightness control.
3.6 Watt LED
Luminous flux: 200 lumen
Luminous intensity: 900 cd
Equivalent to a dichroic halogen lamp with 20W, Equivalent to a standard halogen lamp with 50W
Correlated Color Temperature: 6300K
Pure white, no need of blue correction filter. |
|
Reviews
There are no reviews yet.