Spin Tissue Processor STP 120

$6,050.00

Shipped From Abroad

Myr Spin Tissue Processor STP 120 has been developed to meet the requirements of every single laboratory. The technology and the unique processing method of the STP 120 qualifies it as the most successful Spin Tissue Processors ever. With more than 3.500 units installed around the world confirms its leading position.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130128-3
Brands:: Myr

Description

Features
  • A worldwide unique technique

Tissue processing is a technique than uses alcohols to remove water from tissues and replace it with a medium that allows sectioning of tissue. Several methods are used to achieve this. Myr Spin Tissue Processor STP 120 fulfills it in a patented and unique technique that combines several movements for the tissue to achieve perfect infiltration results. This is possible thanks to the world’s best spin processing method.

  • ROTATIONAL AGITATION

The basket with the cassettes is immersed into the reagent vessel. In this position, the basket turns at 60 rpm and changes the rotational direction every 60 seconds. The rotational agitation achieves a perfect infiltration of tissue, a homogeneous mixture of the reagents and a reduction of processing time. To get better results, the user can start optionally a shaking process.

  • SHAKING

This movement can be optionally activated on the control panel and allows the basket to perform an up-down movement inside the vessel that combined with the rotational agitation fulfills a helicoidal movement that increases infiltration quality at a high degree of precision. At the end of this process, baskets start centrifuging.

  • CENTRIFUGING

This function is activated as soon as the infiltration time comes to an end. The basket rises above the reagent’s level but rests inside the vessel. For a period of 60 seconds, it starts whirling at 210 rpm and changes the rotational direction every 15 seconds. This process allows the tissue to be optimally drained and avoids carry-over of reagents from one vessel to another.

Tissue processing achieves by this method almost similar results to those obtained with vacuum systems!

  • Ergonomic control panel

The buttons of the control panel are arranged ergonomically for easy handling. The LCD display shows all the parameters throughout the process, such as program number, vessel, remaining time, start delay, total duration of the program, rotational agitation and shaking, basket’s centrifuging, temperature of paraffin baths, date and time.

  • Easy handling

The instrument has the capacity to store up to 10 different programs that can be freely set up by the user. Each one of the programs can be started in immediate or delayed mode, without a time limit. The instrument can easily be rotated via the four rollers mounted on the base. This allows the user to have fast and safe access to each one of the vessels.

  • Maximum safety standards for the user and the specimen

The individual cover for each one of the vessels reduces the emission of vapors to a minimum. The STP 120-2 and STP 120-3 versions incorporate a fume extraction system that – through a fan and an active charcoal filter – cleanse the vapors before being discharged into the air. Optional adaptor for the laboratory general extraction system.

In case of a power shutdown, the specimens are automatically lowered inside the vessel by means of a battery to protect them against desiccation and solid paraffins. Once power is restored, the instrument resumes the program at the same point in which it was interrupted. lf it is a long power failure and the paraffin baths become solidified, the safety program will be activated. The instrument will then wait for the baths to be fully liquified before going ahead with the change to the paraffin baths.

Emergency motions can be implemented through the battery, such as moving the basket up and down or station change (as long as the basket is not inside a solidified paraffin bath). The instrument is also equipped with an emergency stop button. It is possible to interrupt a program for reloading or advanced unloading of samples.

  • Alarms during the process

If the specimens remain inside a station for a longer time than the programmed time, e.g. due to a power failure, the display will show a message indicating the station number and the overtime spent in that station compared with the initially programmed time. The acoustic and visual alarms can easily be identified by the user. The keyboard can be locked by the user to avoid an inadvertent change of the process parameters during operation.

Technical Data Spin Tissue Processor STP 120
Power requirements
Nominal voltage 100 – 120 V 220-240 V AC (±10%)
Network’s frequency 50/60 Hz
Consumption 400 VA
Fuses 115 V (2xT4A) 230 V (2xT2A)
Accumulator Nickel-Cadmium 12 V 600 mA
Capacity
Reagent stations
Number of vessels 10 (9 if 3 paraffin baths are used)
Volume per vessel 1,8 l
Paraffin stations
Number 2 (optionally 3)
Volume 1,8 l
Nominal voltage 24 V AC
Nominal power per station 100 VA
Temperature setting range (temperature increase by 1 degree celsius) 45 – 70 °C
Overtemperature release 75 °C (± 4 °C)
Cassette baskets
Number of baskets 1 (optionally 2)
Basket capacity 120 cassettes (optionally 240)
Programming
Number of programs 10 (selectable)
Infiltration time per station from 1 m to 99 h 59 m
Rotational agitation selectable
Shaking selectable
Centrifuging time selectable
Program start delay selectable without time limit
Dimensions
Diameter 850 mm
Height 500 – 700 mm
Diameter of the roller’s circle 670 mm
Weight
Including packaging 130 kg
Net (fully equipped) 70 kg

Optional accessories

Spiral support for a second cassette basket (double processing capacity)
Additional basket
Additional paraffin bath (necessary when operating the processor with two baskets)
Fume extraction system with active charcoal filter

 

Click here to download Catalogue

Reviews

There are no reviews yet.

Be the first to review “Spin Tissue Processor STP 120”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsSpin Tissue Processor STP 120 removeOptika B-292LD1 Binocular LED Fluorescence Microscope removeOptika B-510ASB Trinocular Phase Contrast Microscope removeOptika B-69 Binocular Microscope removeLab/Ward Coat removeLeica Rotary Microtome remove
NameSpin Tissue Processor STP 120 removeOptika B-292LD1 Binocular LED Fluorescence Microscope removeOptika B-510ASB Trinocular Phase Contrast Microscope removeOptika B-69 Binocular Microscope removeLab/Ward Coat removeLeica Rotary Microtome remove
ImageOptika B-292LD1 Binocular LED Fluorescence MicroscopeOptika B-510ASB Trinocular Phase Contrast MicroscopeOptika B-69 Binocular Microscope
SKUSF1033560130128-3SF1033560098-6SF1033560098-9SF1033560098-1SF1033560084-222SF1033560084-167
Rating
Price

$6,050.00

$0.00

$0.00

$0.00

$11.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Myr Spin Tissue Processor STP 120 has been developed to meet the requirements of every single laboratory. The technology and the unique processing method of the STP 120 qualifies it as the most successful Spin Tissue Processors ever. With more than 3.500 units installed around the world confirms its leading position.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad Fluorescence binocular and trinocular microscopes especially designed for tubercolosis and malaria analysis.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad Advanced routine laboratory microscope for brightfield and phase contrast observations with IOS W-PLAN objectives and rackless stage. Ideal for Asbestos analysis in accordance to international rules with 12.5x eyepieces and Walton & Becket graticule to perform perfect asbestos fibers analysis at a glance. The high-efficiency X-LED3 makes it reliable for all transmitted light observations.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Ship from abroad Cordless, modern binocular microscope ideal for students and mainly primary schools with achromatic lenses (1000x), FN 18 eyepieces, finite optical system, coaxial focusing, StagErase™ eraseable mechanical stage, Abbe condenser and 1 W LED illumination with rechargeable batteries.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • This white coat laboratory coat is a knee-length overcoat/smock is perfect for professionals in the medical field or by those involved in laboratory work.
  • This garment is Easy to wash and made from a cotton polyester blend, allowing it to be washed at high temperature and make it easy to see if it is clean.
  • Easy to wash.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The fully automated Leica RM2255 microtome embodies the latest technological innovations in microtomy and perfectly harmonizes practical features with an ergonomic design and user safety. Its two-in-one design concept, which allows motorized as well as manual sectioning, provides reproducible, quality sections.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features
  • A worldwide unique technique
Tissue processing is a technique than uses alcohols to remove water from tissues and replace it with a medium that allows sectioning of tissue. Several methods are used to achieve this. Myr Spin Tissue Processor STP 120 fulfills it in a patented and unique technique that combines several movements for the tissue to achieve perfect infiltration results. This is possible thanks to the world’s best spin processing method.
  • ROTATIONAL AGITATION
The basket with the cassettes is immersed into the reagent vessel. In this position, the basket turns at 60 rpm and changes the rotational direction every 60 seconds. The rotational agitation achieves a perfect infiltration of tissue, a homogeneous mixture of the reagents and a reduction of processing time. To get better results, the user can start optionally a shaking process.
  • SHAKING
This movement can be optionally activated on the control panel and allows the basket to perform an up-down movement inside the vessel that combined with the rotational agitation fulfills a helicoidal movement that increases infiltration quality at a high degree of precision. At the end of this process, baskets start centrifuging.
  • CENTRIFUGING
This function is activated as soon as the infiltration time comes to an end. The basket rises above the reagent’s level but rests inside the vessel. For a period of 60 seconds, it starts whirling at 210 rpm and changes the rotational direction every 15 seconds. This process allows the tissue to be optimally drained and avoids carry-over of reagents from one vessel to another.

Tissue processing achieves by this method almost similar results to those obtained with vacuum systems!

  • Ergonomic control panel
The buttons of the control panel are arranged ergonomically for easy handling. The LCD display shows all the parameters throughout the process, such as program number, vessel, remaining time, start delay, total duration of the program, rotational agitation and shaking, basket’s centrifuging, temperature of paraffin baths, date and time.
  • Easy handling
The instrument has the capacity to store up to 10 different programs that can be freely set up by the user. Each one of the programs can be started in immediate or delayed mode, without a time limit. The instrument can easily be rotated via the four rollers mounted on the base. This allows the user to have fast and safe access to each one of the vessels.
  • Maximum safety standards for the user and the specimen
The individual cover for each one of the vessels reduces the emission of vapors to a minimum. The STP 120-2 and STP 120-3 versions incorporate a fume extraction system that – through a fan and an active charcoal filter – cleanse the vapors before being discharged into the air. Optional adaptor for the laboratory general extraction system. In case of a power shutdown, the specimens are automatically lowered inside the vessel by means of a battery to protect them against desiccation and solid paraffins. Once power is restored, the instrument resumes the program at the same point in which it was interrupted. lf it is a long power failure and the paraffin baths become solidified, the safety program will be activated. The instrument will then wait for the baths to be fully liquified before going ahead with the change to the paraffin baths.

Emergency motions can be implemented through the battery, such as moving the basket up and down or station change (as long as the basket is not inside a solidified paraffin bath). The instrument is also equipped with an emergency stop button. It is possible to interrupt a program for reloading or advanced unloading of samples.

  • Alarms during the process
If the specimens remain inside a station for a longer time than the programmed time, e.g. due to a power failure, the display will show a message indicating the station number and the overtime spent in that station compared with the initially programmed time. The acoustic and visual alarms can easily be identified by the user. The keyboard can be locked by the user to avoid an inadvertent change of the process parameters during operation.
Technical Data Spin Tissue Processor STP 120
Power requirements
Nominal voltage 100 – 120 V 220-240 V AC (±10%)
Network’s frequency 50/60 Hz
Consumption 400 VA
Fuses 115 V (2xT4A) 230 V (2xT2A)
Accumulator Nickel-Cadmium 12 V 600 mA
Capacity
Reagent stations
Number of vessels 10 (9 if 3 paraffin baths are used)
Volume per vessel 1,8 l
Paraffin stations
Number 2 (optionally 3)
Volume 1,8 l
Nominal voltage 24 V AC
Nominal power per station 100 VA
Temperature setting range (temperature increase by 1 degree celsius) 45 – 70 °C
Overtemperature release 75 °C (± 4 °C)
Cassette baskets
Number of baskets 1 (optionally 2)
Basket capacity 120 cassettes (optionally 240)
Programming
Number of programs 10 (selectable)
Infiltration time per station from 1 m to 99 h 59 m
Rotational agitation selectable
Shaking selectable
Centrifuging time selectable
Program start delay selectable without time limit
Dimensions
Diameter 850 mm
Height 500 – 700 mm
Diameter of the roller’s circle 670 mm
Weight
Including packaging 130 kg
Net (fully equipped) 70 kg
Optional accessories
Spiral support for a second cassette basket (double processing capacity)
Additional basket
Additional paraffin bath (necessary when operating the processor with two baskets)
Fume extraction system with active charcoal filter
 
Click here to download Catalogue
Fluorescence binocular and trinocular microscopes especially designed for tubercolosis and malaria analysis. Features:
  • Observation mode: Brightfield.
  • Head: Binocular, 360° rotating and 30° inclined. Interpupillary distance 48-75mm.
  • Dioptric adjustment: On the left eyepiece tube.
  • Eyepieces: WF10x/20 mm, high eye-point and secured by a screw.
  • Nosepiece: Quadruple revolving nosepiece, rotation on ball bearings.
  • Objectives: Equipped with binocular head and following objectives: IOS N-PLAN 10x/0.25 (Cover/No Cover), with anti-fungus treatment IOS N-PLAN 20x/0.40 (Cover/No Cover), with anti-fungus treatment IOS N-PLAN 40x/0.65 (Cover/No Cover), with anti-fungus treatment IOS W-PLAN 100x/0.80 (No Cover, Dry), with anti-fungus treatment
  • Specimen stage: Double layer rackless mechanical sliding stage, 150×139 mm, 75×33 mm X-Y movement range. Vernier scale on the two axes, accuracy: 0.1 mm.
  • Focusing: Coaxial coarse and fine focusing mechanism with limit stop to prevent the contact between objective and specimen. Adjustable tension of coarse focusing knob.
  • Condenser: Abbe N.A. 1.25, with objective-coded iris diaphragm, focusable and centerable.
  • Brightfield Illumination (Fixed Koehler type): X-LED3 with white 3.6 W LED (6,300 K) and light intensity control. Multi-plug 100-240Vac/6Vdc external power supply.
  • Fluorescence Illumination: Extra efficiency LED, with light intensity control. Peak wavelength: 465 nm, Power: 3.6W.
  • Epi Fluorescence Attachment: Slider with 3 positions (2 fluorescence, 1 brightfield), with 1 included filterset: Fluorescence B: EX 460-490, DM 505, EM 515LP: Acridine Yellow, Acridine Orange, Auramine, DiO, DTAF, FITC, GFP, YFP, etc.
 
Click Here To Download Catalogue
Advanced routine laboratory microscope for brightfield and phase contrast observations with IOS W-PLAN objectives and rackless stage. Ideal for Asbestos analysis in accordance to international rules with 12.5x eyepieces and Walton & Becket graticule to perform perfect asbestos fibers analysis at a glance. The high-efficiency X-LED3 makes it reliable for all transmitted light observations. Features:
  • Observation mode: Brightfield, phase contrast.
  • Head: Trinocular (fixed 50/50), 30° inclined, 360° rotating.
  • Interpupillary distance: Adjustable between 50 and 75 mm.
  • Dioptric adjustment: On the left eyepiece tube.
  • Eyepieces: WF10x/22 mm, high eye-point and WF12.5x/18 mm with dioptric adjustment, one with Walton & Beckett graticule.
  • Nosepiece: Quintuple revolving nosepiece, rotation on ball bearings.
  • Objectives: – IOS W-PLAN 4x/0.10 – IOS W-PLAN 10x/0.25 – IOS W-PLAN PH 40x/0.65 – IOS W-PLAN 100x/1.25 (Oil) All with anti-fungus treatment.
  • Specimen stage: Double layer rackless mechanical stage, 233×147 mm, 78×54 mm X-Y range.
  • Focusing: Coaxial coarse (adjustable tension) and fine focusing mechanism with limit stop to prevent the contact between objective and specimen.
  • Condenser: Abbe N.A. 1.25, with objective-coded iris diaphragm, focusable and centerable. With 40x phase contrast slider.
  • Transmitted illumination (Full Koehler type):  X-LED³ with white 3.6 W LED (6,300K) with brightness control. Multi-plug 100-240Vac/6Vdc external power supply.
  Technical Specifications:
Observation Method - Transmitted Light Brightfield Yes
  Phase contrast (Positive type) Yes
  Darkfield As optional
  Simple polarized light As optional
Main Body Type Upright
  Construction material Aluminum die-cast
  Trasportation handle Yes
Head Type Trinocular (Siedentopf)
  Split ratio 50/50
  Inclination 30°
  360° rotating Yes
  Interpupillary distance (mm) 50-75
  Tube inner diameter (mm) 30
Eyepieces Field number (mm) 22
  Magnification 10x
  Planar type Yes
  Micrometric scale As optional
  Diameter of micrometer glass (mm) 26
  High eyepoint (for glass wearers) Yes
  Rubber cup Yes
  Retractable protections Yes
Nosepiece Positions Quintuple
  Reversed Yes
  Bi-directional Yes
  Rotation on ball bearings Yes
  Objective thread RMS
Objectives Optical system
  Anti-fungus treatment Yes
  Parfocal distance (mm) 45
  Standard magnifications 40x-1000x
  Type IOS W-PLAN
  Objectives included 4x/0.10, W.D. 17.3 mm 10x/0.25, W.D. 10 mm PH 40x/0.65, W.D. 0.54 mm 100x/1.25 (Oil), W.D. 0.13 mm
Stage Type Double layer
  Dimensions (mm) 233x147
  Moving mechanism Rackless
  Moving range (mm) 78x54
  Material Anti-scratch painting
  Specimen holder Yes
  Slide number 2
  X-Y Vernier scale Yes
  Vernier scale accuracy (mm) 0.1
Condenser - Multiple Position Type Abbe. Brightfield - Phase contrast
  Number of positions 2 (BF, 40x)
  Numerical aperture (N.A.) 1.25
  Magnification scale for simplified positioning Yes
  Removable Yes
  Diaphragms Iris
  Centrable Yes
  Focusable By rack and pinion
Focusing System Type Coaxial coarse & fine
  Coarse total travel (mm) 25
  Fine total travel (per single rotation) (mm) 0.2
  Fine graduations 100
  Fine resolution (µm) 2
  Upper stop to prevent contact Yes
  Adjustable tension Yes
  Flat knob for ergonomy Yes
Transmitted Illumination Kohler illumination Full
  Type X-LED
  X-LED type X-LED3
  Light source power (W) 3.6
  Brightness control Manual  
  Lifetime (hours) > 65,000
  Temperature (K) 6,300
  Max. required power (W) 6
Power Supply for Transmitted Illumination Type External
  Microscope connector Jack, 2.1 mm
  Power plug type Multi-plug (EU, UK, US)
  Input voltage 100/240 Vac, 50/60 Hz
  Output voltage 6 Vdc  2.5A
Accessories Included Dust cover Yes
  Immersion oil (10ml) Yes
  Tension adjustment tool Yes
  Allen wrench Yes
  Centering telescope Yes
  Green filter Yes
  User Manual Digital version (downloadable)
Additional Information Heating stage (as optional). External rechargeable battery pack (as optional).
Product Weight Height (mm) 405
  Width (mm) 235
  Depth (mm) 370
Product Weight (kg) 9
Cordless, modern binocular microscope ideal for students and mainly primary schools with achromatic lenses (1000x), FN 18 eyepieces, finite optical system, coaxial focusing, StagErase™ eraseable mechanical stage, Abbe condenser and 1 W LED illumination with rechargeable batteries. Slim and easy to carry, it is equipped with arm/wrist rest support to reduce the fatigue during use and long lasting LED illumination to provide over 20 years of use. Features:
  • Observation mode: Brightfield.
  • Head: Binocular, 30° inclined; 360° rotating.
  • Dioptric adjustment: Left eyepiece.
  • Eyepiece: WF10x/18 mm, secured by screw
  • Nosepiece: Quadruple ball bearings revolving nosepiece, reversed.
  • Objectives: – Achromatic 4x/0.10, with anti-fungus treatment – Achromatic 10x/0.25, with anti-fungus treatment – Achromatic 40x/0.65, with anti-fungus treatment – Achromatic 100x/1.25 (oil), with anti-fungus treatment
  • Specimen stage: StagErase™ eraseable mechanical stage, 125×125 mm, 62×24 mm X-Y movement range. Vernier scale on the two axes, accuracy: 0.1 mm.
  • Focusing: Coaxial coarse and fine focusing mechanism with limit stop to prevent the contact between objective and specimen.
  • Condenser: Abbe N.A. 1.25, pre-centered, focusable, with iris diaphragm.
  • Illumination: 1 W LED, with brightness control, rechargeable batteries.
  • Color temperature: 6,300 K. Multi-plug 100-240Vac/5Vdc external power supply.
  Technical Specifications:
Observation Method - Transmitted Light Brightfield Yes
  Simple polarized light As optional
Main Body Type Upright
  Construction material Aluminum die-cast
  Trasportation handle Yes
Head Type Binocular (Siedentopf)
  Inclination 30°
  360° rotating Yes
  Interpupillary distance (mm) 55-75
  Dioptric adjustement On left tube
  Fixing screw for eyepieces Yes
  Tube inner diameter (mm) 23
Eyepieces Field number (mm) 18
  Magnification 10x
  Pointer As optional
  Micrometric scale As optional
Nosepiece Positions Quadruple
  Reversed Yes
  Bi-directional Yes
  Rotation on ball bearings Yes
  Objective thread RMS
Objectives Optical system 160
  Anti-fungus treatment Yes
  Parfocal distance (mm) 35
  Standard magnifications 40x-1000x
  Type Achromatic
  4x/0.10, W.D. 10.6 mm
  10x/0.25, W.D. 7.0 mm
  40x/0.65, W.D. 0.5 mm
  100x/1.25 (Oil), W.D. 0.13 mm
Stage Type Double layer
  Dimensions (mm) 125x125
  Moving mechanism Rack and pinion
  Moving range (mm) 62x24
  Material Anti-scratch painting
  Specimen holder Yes
  Slide number 1
  X-Y Vernier scale Yes
  Vernier scale accuracy (mm) 0.1
Condenser - Single Position Type Abbe
  Numerical aperture (N.A.) 1.25
  Diaphragms Iris
  Focusable By rotation
Focusing System Type Coaxial coarse & fine
  Coarse total travel (mm) 23
  Fine total travel (per single rotation) (mm) 1.2
  Fine graduations 100
  Fine resolution (µm) 12
  Upper stop to prevent contact Yes
Transmitted Illumination Type LED
  Light source power (W) 1
  Brightness control Manual
  Lifetime (hours) > 65,000
  Temperature (K) 6,300
  Max. required power (W) 1.5
Power Supply for Transmitted Illumination Type External
  Microscope connector Jack, 2.1 mm
  Power plug type Multi-plug (EU, UK, US)
  Input voltage 100/240 Vac, 50/60 Hz
  Output voltage 5 Vdc 500 mA
  Rechargeable batteries Yes
  Battery type Ni-MH (3x, AAA size)
  Working time of batteries (hours) 4
  Charging time of batteries (hours) 8
Accessories Included Dust cover Yes
  Immersion oil (10ml) Yes
  User Manual Digital version (downloadable)
Product Dimensions Height (mm) 330
  Width (mm) 135
  Depth (mm) 235
Product Weight (kg) 3.0
  • This white coat laboratory coat is a knee-length overcoat/smock is perfect for professionals in the medical field or by those involved in laboratory work.
  • This garment is Easy to wash and made from a cotton polyester blend, allowing it to be washed at high temperature and make it easy to see if it is clean.
  • Easy to wash.
The fully automated Leica RM2255 microtome embodies the latest technological innovations in microtomy and perfectly harmonizes practical features with an ergonomic design and user safety. Its two-in-one design concept, which allows motorized as well as manual sectioning, provides reproducible, quality sections. Features:
  • Compact, ergonomic design
  • Ergonomically designed handwheel handle
  • Smooth-running handwheel with integrated quick-lock mechanism for safety
  • Enclosed micrometer feed mechanism
  • Low-maintenance cross-roller bearings
  • Two forward and backward coarse feed speeds
  • Alternate trimming and sectioning modes, as indicated on the display
  • Speed control through the cutting window for enhanced efficiency
  • Automatic, variable specimen retraction, depending on sectioning speed
  • Section thickness totalizer and section counter
  • Intuitive control panel
  • Integrated communication display
  • Precise specimen orientation with zero point reference
  • Knife holder design with red colored knife guard
  • Precise lateral knife holder adjustment with click stop settings
  • Spacious and easy-to-clean section waste tray
  • Wide range of accessories
  Technical Specifications: Section thickness Setting thickness setting range: 0.5 – 100 µm Setting values: from 0.5 – 5 µm in 0.5 µm increments from 5 – 20 µm in 1 µm increments from 20 – 60 µm in 5 µm increments from 60 – 100 µm in 10 µm increments Trimming section thickness setting range: 1 – 600 µm Setting values: from 1 – 10 µm in 1 µm increments from 10 – 20 µm in 2 µm increments from 20 – 50 µm in 5 µm increments from 50 – 100 µm in 10 µm increments from 100 – 600 µm in 50 µm increments Object feed:  24 mm ± 1 mm, feed motion via step motor Vertical specimen stroke:  70 mm Sectioning modes:  4   Specimen retraction: In manual operation:  5 – 100 µm in 5 µm increments, can be turned off In motorized operation:  varying with the sectioning speed, can be turned of Electric coarse feed: 300 µm/s and 800 µm/s Sectioning speed: 0.5 – 420 mm/s ± 10% Maximum specimen size (L x H x W): 50 x 60 x 40 mm Specimen orientation horizontal: ±8°, vertical: ±8° Nominal supply voltages: 100/120/230/240 V AC ± 10% Nominal frequency: 50/60 Hz Power draw: 340 VA   Dimensions basic instrument Width (incl. handwheel):  413 mm Depth (incl. waste tray): 618 mm Height (with storage area on cover): 305 mm Weight (without accessories): Approx. 40 kg   Dimensions control panel: W x D x H 121 x 166 x 50 mm Weight: approx. 0.66 kg, approx. 1.45 Ibs Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare