Key Features
  • Single gas (user defined)
  • Backward compatible with ADC’s ‘Eclipse’
  • Linearised Output
  • Continuous status signal to check device health
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130141-15
Brands:: Analox

Description

Description

The Venus Solo OEM sensor is a self-contained unit designed for integration into other manufacturers’ equipment and provides a measurement of gas concentration according to specific user requirements. These GFC (Gas Filter Correlation) sensors generate a signal proportional to the infrared absorption of the measured gas.

Providing the gas concentration lies within the designed range of the sensor, the signal is periodically compared with a reference gas. Gas concentrations are indicated through the non-linearised analogue signal output. Gas connections to and from the sensor are via suitable fittings on the gas measuring cell.

The Venus Solo OEM Series sensors electrical supply is designed to accept 24V DC (3amp max).

Our Venus Solo OEM sensor uses GFC (Gas Filter Correlation) technology to give highly accurate gas measurements.

The Venus Solo can be integrated into your own gas analyzer or management system and offers the user a 0-2.5v analogue output.

The sensor is currently available as either: Carbon dioxide (CO2), carbon monoxide (CO), nitrous oxide (N20), methane (CH4) or nitric oxide (NO). If your application requires a different gas, just let us know and we can customise it to your needs.

The Venus Solo is used in Military applications to protect submariners from carbon monoxide (CO) exposure.

 

Technical Specification

Venus Solo

Reviews

There are no reviews yet.

Be the first to review “VENUS SOLO OEM SENSOR”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsVENUS SOLO OEM SENSOR removeCARBON MONOXIDE MONITORING SYSTEM (AX60+ CO) removeSuper-Full Touch Screen Water Purification System removeAtmosphere Protection Module removePilot-RO Water Purification System removePARTIAL PRESSURE O2 ANALYSER remove
NameVENUS SOLO OEM SENSOR removeCARBON MONOXIDE MONITORING SYSTEM (AX60+ CO) removeSuper-Full Touch Screen Water Purification System removeAtmosphere Protection Module removePilot-RO Water Purification System removePARTIAL PRESSURE O2 ANALYSER remove
Image
SKUSF1033560130141-15SF1033560130141-1SF1033560130126-3SF1033560130141-16SF1033560130126-2SF1033560130141-19
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Key Features
  • Single gas (user defined)
  • Backward compatible with ADC’s ‘Eclipse’
  • Linearised Output
  • Continuous status signal to check device health
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad

The Ax60+ CO protects users in plant rooms, parking garages and anywhere that carbon monoxide can collect. The Ax60+ CO also can be used for online cylinder filling, to protect divers from compressed air contaminated with carbon monoxide related to compressor maintenance or contamination at the compressor inlet.

The Ax60+ CO benefits from the ability to operate as a single sensor and alarm or as part of a system of up to 4 sensors. Each system can also be composed of Ax60+: O2 sensors and Ax60+ CO2 sensors so it can fulfil multiple application needs.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The Super series uses city tap water as the water source, and can easily and quickly produce secondary RO (reverse osmosis) water, EDI deionized water and UP ultrapure water. It uses a standard two-stage reverse osmosis system and Ionpure EDI technology and modules to continuously produce Class II pure water with a TOC of more than 10MΩ.cm (25℃) and <30ppb, and ultrapure water of 18.2MΩ.cm (25℃). System water output: 10 liters/hour, and the daily output of pure water can reach 240 liters.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • Flexible to meet your specific needs and ensures you meet current legislation
  • Measures up to 2 gasses with a choice of; O2 (oxygen), CO2 (carbon dioxide) and R134a (refrigerants). The APM will soon be able to measure VOCs (volatile organic compounds)
  • Uses MODBUS RTU communications protocol
  • Temperature compensated sensors with PressureSync technology
  • Fitted with 2 relays
  • Compatible with the Analox Distributed Atmosphere Monitoring solution (DAMS)
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad An economical choice of primary pure water for daily laboratory cleaning , with a water output of 45 - 180 liters per hour, ion retention rate >98%, organic matter retention rate >99% (when MW >200 Daltons), particle and bacteria retention rate >99%, which can meet the requirements of conventional production process water and laboratory utensil cleaning water, and can be used as the inlet water for ultrapure water systems, high-pressure steam sterilizers, environmental test chambers and other instruments.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • Compact in size making it ideal for confined space use
  • Fitted with a reliable PPO2 sensor, proven and tested within the hyperbaric environment
  • Large LCD display making readings easy to view
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Description
The Venus Solo OEM sensor is a self-contained unit designed for integration into other manufacturers’ equipment and provides a measurement of gas concentration according to specific user requirements. These GFC (Gas Filter Correlation) sensors generate a signal proportional to the infrared absorption of the measured gas. Providing the gas concentration lies within the designed range of the sensor, the signal is periodically compared with a reference gas. Gas concentrations are indicated through the non-linearised analogue signal output. Gas connections to and from the sensor are via suitable fittings on the gas measuring cell. The Venus Solo OEM Series sensors electrical supply is designed to accept 24V DC (3amp max). Our Venus Solo OEM sensor uses GFC (Gas Filter Correlation) technology to give highly accurate gas measurements. The Venus Solo can be integrated into your own gas analyzer or management system and offers the user a 0-2.5v analogue output.

The sensor is currently available as either: Carbon dioxide (CO2), carbon monoxide (CO), nitrous oxide (N20), methane (CH4) or nitric oxide (NO). If your application requires a different gas, just let us know and we can customise it to your needs. The Venus Solo is used in Military applications to protect submariners from carbon monoxide (CO) exposure.  

Technical Specification
Venus Solo
https://youtu.be/--wsZFTYVWs?si=nI8q1AThpkBD4yNv https://youtu.be/Bi7CmSLIIbA?si=dVXlyZaRw893no_T  
Key Features
  • Ambient CO monitoring
  • Online CO monitoring
  • Can be used with Nitrogen (N2) background gasses or, with calibration, can be used with Helium (He) background gasses
  • Has up to 3 user configurable alarms
  • Can operate as a stand alone sensor or as part of a larger system
  • Compatible with the rest of the Ax60+ range
 
Click here to download Quick Start Guide
Click here to download Manual
Click here to download Service Manual
Performance characteristics
  • New 7.0-inch color touch screen

The new 7-inch color 16:9 widescreen high-resolution full touch screen control system provides a new fingertip touch operation experience.

  • 4-channel water quality and 3-channel flow monitoring on the host

Source water, secondary RO water, EDI deionized water, UP ultrapure w

  • The lab optimized standard two-stage reverse osmosis system

The use of dual pumps, dual membranes and transition water tanks reduces system energy consumption and wastewater, ensuring stable water quality under different source water conditions.

ater, 4-way water quality online monitoring and water quality exceeding standard alarm function.

1-way source water flow statistics, EDI deionized water and UP ultrapure water 2-way high-precision quantitative water extraction function.

  • Standard-50L PE pure water tank

The polyethylene pure water tank with conical bottom design contains an air filter, which can effectively absorb CO2, organic matter and filter bacteria and particles, and can be equipped with UV ultraviolet irradiation sterilization components.

Features and Advantages
  • Built-in 3-pump system with primary and secondary RO booster pumps and circulation disinfection pumps to achieve complete two-stage reverse osmosis, system circulation and disinfection functions
  • Full-level filter element alarm prompt function based on time and flow, showing the used and remaining life of consumables
  • Automatic detection and alarm functions such as system water shortage alarm, water tank full alarm, water quality exceeding standard alarm, consumable life end alarm, water leakage protection alarm, etc. provide safety guarantee
  • Fully automatic RO membrane anti-scaling flushing program (flushing interval and duration can be set) to extend the service life of the RO membrane
  • Built-in SD card, can store and view operation data charts and curves, and can be inserted into a USB flash drive for complete data export, providing data traceability
  • With USB interface system program upgrade function, and optional WIFI module
  • Built-in perpetual calendar clock, convenient for consumables management and service settings
  • Ultrapure water full pipeline dosing disinfection function, just add disinfection tablets to start the one-key disinfection program to ensure high-quality pure water
  • Ultrapure water circulation function, which can be started and shut down freely to maintain low bacterial contamination level in the system
  • Factory and customer secondary passwords, system parameter settings are all password protected to prevent unauthorized changes
  • Compatible with 2 pure water storage methods of pressure water barrels to meet different application needs
  • High-strength all-engineering plastic chassis, ergonomic design, beautiful appearance, no corrosion and rust, ensure the cleanliness of the machine body, in line with GLP specifications
  • Unique 4-door design, pretreatment, RO and ultra-purification components, EDI and TOC modules, water tanks and control components adopt independent modular structures, making system maintenance more convenient
  • Pipes and joints are NSF certified to minimize TOC precipitation in the system and ensure the highest pure water quality
  • Powerful pre-treatment components, combined with 5μm PP transparent filter, KDF composite filter, coconut shell water-washing grade precision activated carbon filter, effectively protect the RO membrane
  • DOW RO reverse osmosis membrane, RO membrane components optimized by The lab, achieve the combination of long life, stability and high desalination rate of RO membrane
  • The new integrated ultra-purification component of DOW resin ensures that the water produced reaches 18.2MΩ.cm and reduces TOC precipitation
  • Ultra-long life 254&185nm dual wavelength UV lamp, combined with medical grade 316L flow hood, effectively sterilizes, reduces TOC, and enhances the system's application range
  • UF ultrafiltration components, molecular weight cut-off: MWCO5000D, effectively remove pyrogens/endotoxins, can be used for precision cell culture and IVF
  • Double-layer terminal sterilizing filter, accuracy: (0.45+0.1)μm, using PES polyethersulfone composite filter membrane, double-layer filtration design to ensure the terminal effluent is sterile
 
Technical Parameters
name Basic Heat removal prototype Low organic matter type Comprehensive Built-in TOC monitor
model Super 10 Super 10F Super 10V Super 10FV Super-TOC10V Super-TOC 10FV
Pure water output 10 L/hour
Ultrapure water output Up to 2.0L/min (when there is water in the water tank)
Ultrapure water index
Resistivity (25℃) 18.2MΩ.cm
Total Organic Carbon TOC* <10ppb <10ppb <3ppb <3ppb <3ppb <3ppb
bacteria <0.01cfu/ml
Particles (>0.1μm) <1/ml
Pyrogens/endotoxins N/A <0.001Eu/ml N/A <0.001Eu/ml N/A <0.001Eu/ml
RNases N/A <1pg/ml N/A <1pg/ml N/A <1pg/ml
Deoxyribonucleases (DNases) N/A <5pg/ml N/A <5pg/ml N/A <5pg/ml
Pure water index
Resistivity* >5MΩ.cm
Total Organic Carbon (TOC)* <30ppb
Silicon Rejection Rate >99.9%
Source water requirements Urban drinking tap water, water temperature 5-45℃, water pressure 1.0-4.0Kgf/cm2
Size and weight Length × width × height: 545 × 470 × 649 mm, weight: about 35 kg
Electrical requirements 220-240V, 50/60Hz
power 240W
System Configuration Host (including 1 set of purification column) + TOC monitor (TOC type) + 50L PE ultrapure water storage tank
   
Descriptions
The Analox APM (Atmosphere Protection Module) is a configurable modular system which has the ability to monitor up to 2 gasses. This unique solution can be used as a stand alone atmosphere monitor or it can be integrated into existing PMS systems.  
Technical Specifications
System Specifications
Operating Temperature 0°C to +45°C +32°F to +113°F
Operating pressure 700 to 1300mBar
Humidity Range 0 to 95% RH
Power 24vDC (nominal) as standard
Communications MODBUS RTU
Relays 2 as standard
Calibration interval Before mission and / or every 3 months
Sensor Unit
Sensor type Range Danger
CO2 NDIR 0 to 5% / 0 to 30mBar Toxic
O2 (Depleted) Electrochemical 0 to 25% / 0 to 2500mBar Asphyxiation
O2 (enriched) Electrochemical 0 to 25% / 0 to 2500mBar Fire/explosion
R134a NDIR 0 to 1000ppm Asphyxiation
VOCs PID 0 to 20ppm Toxic
Click here to download Data Sheet
Download Pumped Detectors Technical Manual
An economical choice of primary pure water for daily laboratory cleaning , with a water output of 45 - 180 liters per hour, ion retention rate >98%, organic matter retention rate >99% (when MW >200 Daltons), particle and bacteria retention rate >99%, which can meet the requirements of conventional production process water and laboratory utensil cleaning water, and can be used as the inlet water for ultrapure water systems, high-pressure steam sterilizers, environmental test chambers and other instruments
Technical Parameters
Product Model Pilot-RO45 Pilot-RO63 Pilot-RO90 Pilot-RO120 Pilot-RO180
Pure water output* 45L/Hour 63L/Hour 90L/Hour 120L/Hour 180L/Hour
RO reverse osmosis water indicators
 Ion retention rate 98%-99% (when using new RO membrane)
 Organic matter retention rate >99%, when MW>200 Daltons
 Particle and bacteria retention >99%
 bacteria <0.01 cfu/ml (optional 0.2μm imported PES terminal filter)
 Particles (>0.2μm) <1/ml (optional (0.2μm imported PES terminal filter)
Raw water requirements Urban drinking tap water, water temperature 5-45℃, water pressure 1.0-4.0Kgf/ cm2
Size and weight Length × width × height: 640 × 540 × 1110mm; Weight: about 70Kg
Electrical requirements 220V, 50/Hz
power 120W 120W 240W 240W 240W
System Configuration Main unit (including 1 set of purification column) + 2 built-in 15L pressure water buckets + TDS/conductivity test pen + accessory bag
Description
The HYP is a rugged and compact portable partial pressure monitor. Simple to operate, the HYP accurately reads oxygen (O2) levels within the hyperbaric environment.
O2 monitoring with the HYP
Classification bodies and industry guidelines within the diving market require each hyperbaric chamber to have a means of providing independent oxygen (O2) monitoring in the event of the primary monitor failing. The HYP is a portable PPO2 monitor capable of helping you to achieve such guidelines.  
Oxygen Sensor
The compact size allows for convenient fitting within confined spaces such as diving bells and hyperbaric lifeboats, or alternatively the unit can easily be hand carried. It is very simple to use, with just a single push-button to switch power on and off, and an LCD display. It may be used at depths of up to 600MSW / 2000FSW, and can also be used at surface pressures.
Technical Specification
HYP
Click here to download Data Sheet
Click here to download Quick Start Guide
Click here to download User Manual
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare