Description | In Stock
- Light weight lead core for protection; Velcro enclosure
- 0.5mm Lead (pb) Equivalency Protection
- Stain resistant and washable material
- Easy to wear ; One size fits all
| In Stock
GXR Analogue X-ray system matches with a radiographic room which perfectly fits your workow and can be easily upgraded to DR system with the help of DR interface and PC interface in GXR generator as well as Bucky suitable to Flat Panel Detector. GXR X-ray system is equipped with a high frequency X-ray generator which consistently produces high quality radiograph in favor of high quality X-ray output with a very small kV ripple and accurate mA and mAs. GXR X-ray system is designed to provide convenience to operator and comfort to patient.
Delivery & Availability:
Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from abroad
The DrGem Ceiling Analogue X-ray Machine is a diagnostic radiography system that provides reliable high quality radiographic images with a reduced dose. The reliable high-frequency x-ray generators that are known worldwide for their excellent performance, lifetime and stability. Patient tables and wall stands are also offered.
Delivery & Availability:
Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
- Length: 355 mm
- Height: 560 mm
- Diameter: 150 mm
- Power: 30 w
- Scattering diffusion: Greater than 0.9
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad
SuperMark 1.5T is a new generation superconducting MRI system based on years of experience in production and research. It's applicable to whole body scan, such as, nervous system, spine, joint soft tissue, pelvic and abdominal cavity, etc
Delivery & Availability:
Typically 90 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In Stock
The GXR-SD is a diagnostic digital radiography system that provides reliable high quality digital radiographic images with a reduced dose. The GXR-SD DR systems offer comprehensive digital solutions to all radiography needs, featuring ACQUIDR digital imaging system with stationary or portable digital flat-panel detectors as well as reliable high-frequency x-ray generators that are known worldwide for their excellent performance, lifetime and stability. Patient tables and wall stands are also offered.
Delivery & Availability:
Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
Content |
- Light weight lead core for protection; Velcro enclosure
- 0.5mm Lead (pb) Equivalency Protection
- Stain resistant and washable material
- Easy to wear ; One size fits all
| DrGem GXR Floor Mounted Analogue X-ray system matches with a radiographic room which perfectly fits your workflow and can be easily upgraded to DR system with the help of DR interface and PC interface in GXR generator as well as Bucky suitable to Flat Panel Detector. GXR (Analogue X-ray)system is equipped with a high frequency X-ray generator which consistently produces high quality radiograph in favor of high quality X-ray output with a very small kV ripple and accurate mA and mAs. GXR (Analogue X-ray) system is designed to provide convenience to operator and comfort to patient.
Features of DrGem GXR Floor Mounted Analogue X-ray:
- 4 way Tabletop Patient Table (PBT-4)
A large tabletop with extended travel enables all radiography studies with minimal patient movement, and supporting patient weight up to 300kg. Fully at tabletop without a frame on the edge makes cleanliness and odors free
- Floor Mount Tube Stand (TS-FM6)
Floor Rail type tube stand provides all radiography studies with smooth movement on the rail.
- Wall Bucky Stand (WBS)
Elegant design, durable and easy-to-use Wall Bucky Stand provides full satisfaction.
Technical Specifications of DrGem GXR Floor Mounted Analogue X-ray:
- Power Rating - 32KW
- Generator - GXR-32S
- Rotor - Dual Speed Starter(DSS)
- Input Power - 400/480VAC, Three phase
- Line Frequency - 50/60Hz
- X-ray tube - DXT-12M, (0.6/1.2mm, 300kHU)
- Tube Voltage - 40 to 150kV, 1kV Step
- Tube Current – 10 to 640mA
- Output - 640mA@81kV, 500mA@104kV, 400mA@130kV, 320mA@150kV
- Time Range - 1ms to 10s
- mAs Range - 0.1 to 800mAs
- Reproducibility - Coecient of Variation : kV < 0.005, Time < 0.005,mAs < 0.01
- Accuracy - kV < ±(1%+1kV), mA < ±(3%+1mA), Time <±(1%+0.5ms), mAs < ±(3%+0.1mAs)
- Linearity - Coecient of Linearity < 0.01 : CL = (X1-X2)/(X1+X2), where X is mR/mAs
| DrGem Ceiling Analogue X-ray Machine is a diagnostic radiography system X-ray Machine that provides reliable high quality radiographic images with a reduced dose. The reliable high-frequency x-ray generators that are known worldwide for their excellent performance, lifetime and stability. Patient tables and wall stands are also offered.
Features of DrGem Ceiling Analogue X-ray Machine
- TS-CSA-A (Vertical movement, 1.6m stroke, rail length 3x4meter) including HV cable 15m
- WBS-TA: Vertical movement
- V Stroke:1,450mm in Uprigh Bucky Position,
- 1,526mm in Horizontal Bucky position.
- PBT-4 is a 4 way Floating Tabletop with. A large tabletop with extended travel enables all radiography studies with minimal patient movement. Fully fat tabletop without a frame on the edge makes cleanliness and odors free
Technical Specifications of DrGem Ceiling Analogue X-ray Machine
- Power Rating - 32KW
- Generator - GXR-32S
- Rotor - Dual Speed Starter(DSS)
- Input Power - 400/480VAC, Three phase
- Line Frequency - 50/60Hz
- X-ray tube - DXT-12M, (0.6/1.2mm, 300kHU)
- Tube Voltage - 40 to 150kV, 1kV Step
- Tube Current – 10 to 640mA
- Output - 640mA@81kV, 500mA@104kV, 400mA@130kV, 320mA@150kV
- Time Range - 1ms to 10s
- mAs Range - 0.1 to 800mAs
- Reproducibility - Coecient of Variation : kV < 0.005, Time < 0.005,mAs < 0.01
- Accuracy - kV < ±(1%+1kV), mA < ±(3%+1mA), Time <±(1%+0.5ms), mAs < ±(3%+0.1mAs)
- Linearity - Coecient of Linearity < 0.01 : CL = (X1-X2)/(X1+X2), where X is mR/mAs
- Mechanical Parts:
-TS-CSA-A (Vertical movement, 1.6m, stroke rail length 3x4meter) including HV cable 15m
- PBT-4: 4 way Floating Tabletop with Elevating Feature (66cm).
- WBS-TA: a. Vertical movement
- V Stroke:1,450mm in Upright Bucky
- Position, 1,526mm in Horizontal Bucky position.
- HVC-15: 15M HV cable
- Auto Collimator
|
- Length: 355 mm
- Height: 560 mm
- Diameter: 150 mm
- Power: 30 w
- Scattering diffusion: Greater than 0.9
| SuperMark 1.5T is a new generation superconducting MRI system based on years of experience in production and research. It's applicable to whole body scan, such as, nervous system, spine, joint soft tissue, pelvic and abdominal cavity, etc. SuperMark 1.5T provides not only conventional pulse sequences and clinical diagnosis functions, but also provides advanced functional applications, for instance, 3D angiography and water imaging. It adopts brand new ANKE APEX operating system which ensures easy operation and fast diagnosis.
Technical Advantages:
- Reliable short cavity superconducting magnet system with zero liquid helium
consumption
- New generation fully digitalized and extensible multichannel spectrometer
- Powerful high efficiency and high fidelity gradient system; Multi-channel PA RF
receiving coil with intelligent identification
- English operating system and high extensible computer system
- High resolution conventional clinical images; Practical advanced functional
imaging
Superconducting MRI System:
- Highly open and humanization design -> Streamlined design
- Rich sequences and technology satisfy clinical needs -> Efficient service
Low Investment:
- High cost performance superconducting MRI system
- Zero liquid helium consumption, low running and maintenance cost
- Core technology by independent R & D supports full upgrade
- Low electric consumption
- Compact magnet design, minimum installation space: 35 square meters
High Return:
- High resolution thin slice images improve diagnosis
- Short cavity magnet design makes patients comfortable
- Fast scan speed improves work efficiency
Technical Specifications:
No. |
Technique Description |
Parameter |
1 |
Magnet System |
|
1.1 |
Magnet Type |
Permanent Magnet
Automatic constant temperature
system |
1.2 |
Field Strength |
0.51T |
1.3 |
Magnet Shape |
Dual-pillar shape |
1.4 |
Homogeneity(40cm,DSV,VRMS) |
≤1.6ppm |
1.5 |
Shim Method |
Active/Passive |
1.6 |
Magnet Vertical Gap (Cover) |
40cm |
1.7 |
Magnetic Pole Dia. (Exclude Cover) |
145cm |
1.8 |
Accessibility(Horizontal Opening Angle, |
280° |
1.9 |
5 Gauss fringe field |
X-axis:horizontal ≤2.5m
Y-axis:Vertical ≤2.5m
Z-axis:horizontal ≤2.5m |
2 |
Patient Couch and Communication |
|
2.1 |
Patient Couch Driven mode |
Motor-driven |
2.2 |
Max. Patient Weight |
≥200kg(440lbs) |
2.3 |
Patient Positioning Tools |
Laser Light Localizer for positioning of center slice Motor-driven transfer to center of imaging volume |
2.4 |
Position accuracy |
±1mm |
2.5 |
Emergency Call Key |
Yes |
2.6 |
Intercom System |
Yes |
3 |
Gradient System |
|
3.1 |
Gradient Field Strength(Single Axis) |
≥30mT/m |
3.2 |
Gradient Slew Rate (Single Axis) |
≥100mT/m/ms |
3.3 |
Rise Time |
≤0.3ms |
3.4 |
Gradient Cooling System ( Gradient coils
and Power electronics) |
Air Cooling |
4 |
RF System |
|
4.1 |
RF System Type |
Digital Transmit and
Receive signal |
4.2 |
Number of RF Channels |
4 |
4.3 |
Transmitter Amplifier Peak Power |
6kW |
4.4 |
RF Bandwidth of Receiver |
≥1.25MHz |
4.5 |
Head Coil |
Yes |
4.6 |
Neck Coil |
Yes |
4.7 |
Body/Spine Coil (17 inch) |
Yes |
4.8 |
Body/Spine Coil (21 inch) |
Yes |
4.9 |
Knee Coil |
Yes |
4.10 |
Shoulder Coil |
Yes |
4.11 |
Flexible Coil |
Optional |
4.12 |
Breast Coil |
Optional |
5 |
Computer System |
|
5.1 |
Host Computer |
DELL Computer (for MR) |
5.2 |
System Software |
Windows XP |
5.3 |
Operation Software |
APEX |
5.4 |
CPU Clock rate |
3.0GHz |
5.5 |
Main Memory |
4GB |
5.6 |
Color LCD Monitor |
19” |
5.7 |
Keyboard and Mouse |
Standard |
5.8 |
Image Reconstruction Speed(256 x 256
Matrix) |
200 frame/Sec. |
5.9 |
Hard Disk |
500GB |
5.10 |
Image Storage Capacity(256 x 256
Matrix) |
500,000 |
5.11 |
Media Driver |
DVD RW |
5.12 |
DICOM 3.0 |
Yes |
5.13 |
Ethernet |
Yes |
5.14 |
Operation Console |
Yes |
5.15 |
Operation Chair |
Yes |
6 |
Scanning Parameter |
|
6.1 |
Max. FOV |
410mm |
6.2 |
Min. FOV |
5mm |
6.3 |
Min. TE(SE) |
5ms |
6.4 |
Min. TR(SE) |
11ms |
6.5 |
Min. TE(GR) |
1ms |
6.6 |
Min. TR(GR) |
3ms |
6.7 |
Min. 2D Thickness |
1.0mm |
6.8 |
Min. 3D Thickness |
0.1mm |
6.9 |
Max. Image Matrix |
512x512 |
7 |
Scanning Sequence & Imaging Technique |
|
7.1 |
Spin Echo 2D/3D (SE 2D/3D) |
Yes |
7.2 |
DE/QE |
Yes |
7.3 |
Fast Spin Echo 2D/3D(FSE 2D/3D) |
Yes |
7.4 |
Single Shot FSE 2D/3D |
Yes |
7.5 |
Inversion Recovery(IR) |
Yes |
7.6 |
Fast Inversion Recovery(FIR) |
Yes |
7.7 |
Gradient Echo 2D/3D(GR 2D/3D) |
Yes |
7.8 |
Fast GR 2D/3D |
Yes |
7.9 |
SPGR |
Yes |
7.10 |
FLAIR |
Yes |
7.11 |
Fat Imaging |
Yes |
7.12 |
Fat Suppression imaging |
Yes |
7.13 |
Water-Fat Separation imaging |
Yes |
7.14 |
TOF MRA(2D/3D) |
Yes |
7.15 |
MRCP(2D/3D) |
Yes |
7.16 |
MRU (2D/3D) |
Yes |
7.17 |
MRM |
Yes |
7.18 |
Fast Hydrograph Imaging |
Yes |
7.19 |
Diffusion Weighted Imaging(DWI) |
Yes |
7.20 |
Max. b Value |
1000s/mm2 |
7.21 |
Breath Hold Technology |
Yes |
7.22 |
Magnetization Transfer Contrast(MTC) |
Yes |
7.23 |
Multi-slice and Angle-free Presaturation |
Yes |
7.24 |
Saturation Tracking |
Yes |
7.25 |
Maximum Intensity Projection(MIP) |
Yes |
7.26 |
Multi-Angle Projection(MAP) |
Yes |
7.27 |
3D Reconstruction |
Yes |
7.28 |
Multi-planar Reconstruction(MPR) |
Yes |
7.29 |
Multi-Artifacts Eliminating technology |
Yes |
7.30 |
Checking with Part Metal Implant |
Yes |
7.31 |
Online Image Filtration |
Yes |
7.32 |
Online Post Procession |
Yes |
7.33 |
3D Scout |
Yes |
7.34 |
Scanning Protocol Preset |
Yes |
7.35 |
Scanning Protocol Queue Waiting |
Yes |
7.36 |
Advanced Image Post Processing |
Yes |
7.37 |
Image Fusion Technology of Vascular |
Yes |
7.38 |
Image Fusion Technology of Spine |
Yes |
| DrGem Ceiling Mounted Digital X-ray is a diagnostic digital radiography system that provides reliable high quality digital radiographic images with a reduced dose. The GXR-SD DR systems offer comprehensive digital solutions to all radiography needs, featuring ACQUIDR digital imaging system with stationary or portable digital flat-panel detectors as well as reliable high-frequency x-ray generators that are known worldwide for their excellent performance, lifetime and stability. Patient tables and wall stands are also offered.
Features:
- TS-CSA-A (Vertical movement, 1.6m stroke, rail length 3x4meter) including HV cable 15m
- WBS-TA: Vertical movement
- V Stroke:1,450mm in Uprigh Bucky Position,
- 1,526mm in Horizontal Bucky position.
- PBT-4 is a 4 way Floating Tabletop. A large tabletop with extended travel enables all radiography studies with minimal patient movement. Fully fat tabletop without a frame on the edge makes cleanliness and odors free
- Digital Flat Panel Detector (FPD) – Wireless 17X14 (Csl, 4336W) with Auto Exposure Detection (AED) function, there is no DR trigger cable between detector and generator.
- Full Featured Imaging Software & Excellent Digital Image Processing:
- Provides convenient user interface and easy operation
- Anatomical view-based digital image processing automatically optimizes and enhances the quality of the captured image for the pictured anatomy.
- Radiographic stand & automatic collimator control function
- DICOM 3.0 networking interface includes Worklist, Print, Store, Query for integration with any PACS or RIS
- Included – Software, HP Laptop Computer
- CPU≥3.2GHz
- Memory capacity:≥4GB
- Hard drive capacity :≥500 GB
- Resolution: 1280 x 1024
- Display size: 21 inch color LCD screen
- 64 bit Windows 10 operation system
- Core: i5
Technical Specification:
- Power Rating - 32KW
- Generator - GXR-32S
- Rotor - Dual Speed Starter(DSS)
- Input Power - 400/480VAC, Three phase
- Line Frequency - 50/60Hz
- X-ray tube - DXT-12M, (0.6/1.2mm, 300kHU)
- Tube Voltage - 40 to 150kV, 1kV Step
- Tube Current – 10 to 640mA
- Output - 640mA@81kV, 500mA@104kV, 400mA@130kV, 320mA@150kV
- Time Range - 1ms to 10s
- mAs Range - 0.1 to 800mAs
- Reproducibility - Coecient of Variation : kV < 0.005, Time < 0.005,mAs < 0.01
- Accuracy - kV < ±(1%+1kV), mA < ±(3%+1mA), Time <±(1%+0.5ms), mAs < ±(3%+0.1mAs)
- Linearity - Coecient of Linearity < 0.01 : CL = (X1-X2)/(X1+X2), where X is mR/mAs
- Mechanical Parts:
-TS-CSA-A (Vertical movement, 1.6m, stroke rail length 3x4meter) including HV cable 15m
- PBT-4: 4 way Floating Tabletop.
- WBS-TA: a. Vertical movement
- V Stroke:1,450mm in Upright Bucky
- Position, 1,526mm in Horizontal Bucky position.
- HVC-15: 15M HV cable
- Auto Collimator
|
Reviews
There are no reviews yet.