Atmosphere Protection Module

$0.00

Shipped From Abroad

Key Features
  • Flexible to meet your specific needs and ensures you meet current legislation
  • Measures up to 2 gasses with a choice of; O2 (oxygen), CO2 (carbon dioxide) and R134a (refrigerants). The APM will soon be able to measure VOCs (volatile organic compounds)
  • Uses MODBUS RTU communications protocol
  • Temperature compensated sensors with PressureSync technology
  • Fitted with 2 relays
  • Compatible with the Analox Distributed Atmosphere Monitoring solution (DAMS)
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130141-16
Brands:: Analox

Description

Descriptions

The Analox APM (Atmosphere Protection Module) is a configurable modular system which has the ability to monitor up to 2 gasses. This unique solution can be used as a stand alone atmosphere monitor or it can be integrated into existing PMS systems.

 

Technical Specifications

System Specifications

Operating Temperature 0°C to +45°C +32°F to +113°F
Operating pressure 700 to 1300mBar
Humidity Range 0 to 95% RH
Power 24vDC (nominal) as standard
Communications MODBUS RTU
Relays 2 as standard
Calibration interval Before mission and / or every 3 months

Sensor Unit

Sensor type Range Danger
CO2 NDIR 0 to 5% / 0 to 30mBar Toxic
O2 (Depleted) Electrochemical 0 to 25% / 0 to 2500mBar Asphyxiation
O2 (enriched) Electrochemical 0 to 25% / 0 to 2500mBar Fire/explosion
R134a NDIR 0 to 1000ppm Asphyxiation
VOCs PID 0 to 20ppm Toxic
Click here to download Data Sheet
Download Pumped Detectors Technical Manual

Reviews

There are no reviews yet.

Be the first to review “Atmosphere Protection Module”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsAtmosphere Protection Module removeCOMPRESSED BREATHING AIR MONITOR removeSmart-RO Water Purification System removeLOW LEVEL CARBON MONOXIDE MONITOR removeAx60+ Kiosk removeConical Glass Flask 250ml remove
NameAtmosphere Protection Module removeCOMPRESSED BREATHING AIR MONITOR removeSmart-RO Water Purification System removeLOW LEVEL CARBON MONOXIDE MONITOR removeAx60+ Kiosk removeConical Glass Flask 250ml remove
Image
SKUSF1033560130141-16SF1033560130141-3SF1033560130126-1SF1033560130141-4SF1033560130141-6SF1033560084-158
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$5.70

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Key Features
  • Flexible to meet your specific needs and ensures you meet current legislation
  • Measures up to 2 gasses with a choice of; O2 (oxygen), CO2 (carbon dioxide) and R134a (refrigerants). The APM will soon be able to measure VOCs (volatile organic compounds)
  • Uses MODBUS RTU communications protocol
  • Temperature compensated sensors with PressureSync technology
  • Fitted with 2 relays
  • Compatible with the Analox Distributed Atmosphere Monitoring solution (DAMS)
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • Provides continuous monitoring 24/7
  • Low maintenance and is easy to install and maintain
  • Provides 90 days of datalogging which you can easily retrieve via a USB connection
  • Cost effective alternative to colorimetric tube testing
  • Supplied as either a fixed or portable version depending upon your needs
  • Can be used on any breathing air compressor
  • Digital display
 
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad An economical choice of primary pure water for daily laboratory cleaning, with an hourly water output of 15-30 liters, ion retention rate >97%, organic matter retention rate >99% (when MW >200 Daltons), particle and bacteria retention rate >99%, which can meet the water requirements for routine laboratory ware cleaning and can be used as the inlet water for ultrapure water systems, high-pressure steam sterilizers, environmental test chambers and other instruments.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • Highly accurate 4-pin sensor
  • >3-year expected cell life
  • Temperature compensation Sub-ppm gas measurement
  • RS485 digital output
  • Optional pressure sensor
  • Easy cell replacement
  • High stability, low drift
  • Easy cell replacement
  • High stability, low drift
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • Low maintenance
  • Quick Connect System
  • Pre-wired, ready to go
  • Can support up to 4 alarm units
  • Push button for unit testing
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • 250ml graduated glass erlenmeyer flask
  • Made from borosilicate with low thermal expansion rate,high temperature tolerance, high strength and hardness
  • High chemical properties,base resistance and acid resistance
  • Narrow mouth design with 29/40 ground joints
  • Large marked metric scale,easy to read
  • Fit for lab chemistry experiment
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Descriptions
The Analox APM (Atmosphere Protection Module) is a configurable modular system which has the ability to monitor up to 2 gasses. This unique solution can be used as a stand alone atmosphere monitor or it can be integrated into existing PMS systems.  
Technical Specifications
System Specifications
Operating Temperature 0°C to +45°C +32°F to +113°F
Operating pressure 700 to 1300mBar
Humidity Range 0 to 95% RH
Power 24vDC (nominal) as standard
Communications MODBUS RTU
Relays 2 as standard
Calibration interval Before mission and / or every 3 months
Sensor Unit
Sensor type Range Danger
CO2 NDIR 0 to 5% / 0 to 30mBar Toxic
O2 (Depleted) Electrochemical 0 to 25% / 0 to 2500mBar Asphyxiation
O2 (enriched) Electrochemical 0 to 25% / 0 to 2500mBar Fire/explosion
R134a NDIR 0 to 1000ppm Asphyxiation
VOCs PID 0 to 20ppm Toxic
Click here to download Data Sheet
Download Pumped Detectors Technical Manual
A Reliable Tool
The ACG+ offers continuous monitoring of up to five different gas variables (oxygen, carbon monoxide, carbon dioxide, volatile organic compounds and water vapor) and simultaneously displays results for testing and calibration purposes. This eliminates potential delays and downtimes while test results are sent out for analysis. The ACG+ has also made cumbersome colorimetric tubes obsolete by drastically reducing the potential for human error in gas analysis. The continuous monitoring also has virtually eliminated the need for time-consuming spot checks. The ACG+ simultaneously scans for O2, CO2, CO, VOCs and water vapor, making it one of the most versatile tools any vessel can utilize. The automatic data log provides additional peace of mind for decision makers.  
A Cost Effective Solution
You can’t put a price on safety, reliability and peace of mind. The Analox development team created the ACG+ to combine multiple tasks simultaneously, reducing the need for multiple analyzer units, costly test tubes, and often, extended times in port for repairs. The ACG+ is available in either a fixed location model or convenient portable units. This adaptability provides designers, procurement officers and equipment specialists some options in closed quarter situations.  
A Tool, Easy To Install And Maintain
While each ACG+ unit can monitor up to five gasses simultaneously, each analytical system operating in the ACG+ is independent of the others. This means sensors can be replaced individually without needlessly causing downtime.  
An Easy Choice

The Analox ACG+ has been proven effective in military situations around the world. The unit’s continuous and specific monitoring capabilities make it an easy choice for key decision-makers.

 
Technical Specifications
ACG+
Power 24V DC
Optional battery power NiMH or Li-ION
Optional mains adaptor Universal input 95 to 250 V AC, 50/60 Hz
IP Rating IP45
Response Time T90 <120 seconds T90 <15 minutes H2O sensor
Temperature Operating: −5 °C to 50 °C / 23°F to 122°F Storage: −10 °C to 60°C / 14°F to 140°F
Flow rate 0.5L per minute (max)
Inlet Pressure 5-10 Bar Gauge (Optional regulator can be purchased)
Humidity 0-99% RH (Non Condensing)
Outputs 1 x normally open relay contacts 1 x normally closed relay contacts 3 x 24 V DC switched output
ACG+ Sensors
O2 Sensor CO2 Sensor CO Sensor VOC Sensor Water Vapor Sensor
Range 0 to 50% 0 to 1000 ppm 0 to 20 ppm 0 to 100 ppm 0 to 100 mg/m3
Accuracy ±(0.035% O2 + 1% of reading + ±(0.035% O2 + 1% of reading + 0.15% of reading/°C) ±(25 ppm CO2 + 1% of reading + 1 ppm CO2/°C) ±(1 ppm CO + 5% of reading + 0.1 ppm CO/°C) ±(1 ppm VOC + 5% of reading + 0.25% of reading/°C) ±(0.15 mg/m3 H2O + 20% of reading)
Technology Analox MEC intelligent electrochemical oxygen sensor Analox 5S3 intelligent NDIR sensor Analox MEC intelligent electrochemical sensor Analox MEC intelligent PID sensor Water vapour sensor using capacitive technology
Click here to download Data Sheet
Click here to download Quick Start Guide
Click here to download User Manual
Technical Parameters
Product Model Smart-RO15 Smart-RO30
Pure water output* 15L/Hour 30L/Hour
Instantaneous water output** Up to 2.0L/Min (when there is water in the water tank)
RO reverse osmosis water indicators
 Ion retention rate 97%-99% (when using new RO membrane)
 Organic matter retention rate >99%, when MW>200 Daltons
 Particle and bacteria retention >99%
 bacteria <0.01 cfu/ml (optional (0.45+0.1)μm imported PES terminal filter)
 Particles (>0.2μm) <1/ml (optional (0.45+0.1)μm imported PES terminal filter)
Raw water requirements Urban drinking tap water, water temperature 5-45℃, water pressure 1.0-4.0Kgf/ cm2
Instantaneous water output 2.0L/min (pressure water bucket required)
Water outlet 1: RO reverse osmosis water
Dimensions/weight Length × width × height: 41 × 22 × 42 cm / about 20 kg
Electrical requirements 100-240V, 50/60Hz
power 48W 72W
System Configuration Main unit (including 1 set of purification column) + 15L pressure water bucket + TDS/conductivity test pen + accessory bag
Consumables Information
Part Number/Model Product Name Service life/root (estimated)
PC-M-PP 5μmPP depth filter element About 2-6 months
PC-PP-ZK Zikang PP filter element About 2-6 months*
PC-AC-B-ZK Zikang activated carbon filter About 4-6 months*
PTC-AC-HZS1 Organic matter purification column About 6800 liters of pure water
RO-100GPD 100GPDRO membrane About 1-2 years
RO-200GPD 200GPDRO membrane About 1-2 years
PTC-MBR-K Deionization purification column (imported resin) About 1000 liters of pure water/column
PTC-UPPR-K Ultrapure water column (imported resin) About 1000 liters of pure water/column
TF-(0.45+0.1)μm-S (0.45+0.1)μm imported PES terminal filter -
UF-5000D MWCO5000DUF ultrafiltration component (original imported) -
UV-(185nm&254nm)-10W-K Dual wavelength (185nm & 254nm) UV lamp assembly (imported) -
LAMP-(185nm&254nm)-10W-K Dual wavelength (185 & 254nm) UV lamp (imported) About 9000 hours
UV-254-10W-K 254nmUV ultraviolet lamp assembly (imported lamp tube) -
LAMP-254-10W-K 254nm UV lamp (imported) About 9000 hours
Description
The TEC CO is a device for monitoring very low levels of carbon monoxide (CO). This is housed in a robust miniature enclosure rated for IP55 ingress protection, with built-in temperature compensation and an RS485 digital output via Analox communications protocol. The sensors are backwards-compatible with the existing MEC (mini electrochemical) range and offer the same modular approach to gas monitoring.  
Technical Specifications
TEC CO
CO2 MONITOR & ALARM DESIGNED FOR KIOSKS

The Ax60+ Kiosk is a CO2 monitor and alarm specifically designed by Analox to alert personnel to a build up/leak of CO2 using a state-of-the-art infrared sensor. The alarm provides both audio and visual alerts in the case of increased levels of carbon dioxide (CO2). Up to four alarms can be added as needed and the unit does not need periodic calibration.

CO2 monitoring with the AX60+ Kiosk
The Ax60+ Kiosk is a smaller version of the popular Ax60+ carbon dioxide (CO2) monitor. It is simple to wall mount in the area where carbon dioxide (CO2) is stored or piped. The Ax60+ Kiosk sensor needs to be installed at a height of 12-18 inches (305-457mm) above the floor – this is because the carbon dioxide (CO2) that leaks from a gas cylinder is denser than ambient air and can collect at low levels. The alarm should be located above the sensor at about head height or at the entrance to the kiosk.  
Technical Specification
Sensor Unit
  • 250ml graduated glass erlenmeyer flask
  • Made from borosilicate with low thermal expansion rate,high temperature tolerance, high strength and hardness
  • High chemical properties,base resistance and acid resistance
  • Narrow mouth design with 29/40 ground joints
  • Large marked metric scale,easy to read
  • Fit for lab chemistry experiment
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare