DynaMesh-IPOM

$0.00

Shipped From Abroad

DynaMesh®-IPOM and DynaMesh®-IPOM visible implants are intended for the surgical treatment of epigastric hernias, umbilical or incisional hernias, and the treatment of parastomal hernias following ostomy surgery, and permanently bridge and reinforce the soft tissue of the abdominal wall in the area of the abdominal wall defect.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130161-4
Brands:: Dyna Mesh

Description

DynaMesh®-IPOM and DynaMesh®-IPOM visible implants are primarily made of polyvinylidene fluoride (PVDF).
The mesh implants are warp-knitted using coloured and uncoloured polyvinylidene fluoride (PVDF) monofilaments and uncoloured polypropylene (PP) monofilaments.

 

Positioning
DynaMesh®-IPOM and DynaMesh®-IPOM visible implants have a parietal side and a visceral side. The parietal side is identified by the green filament ends and consists of PVDF on the surface and a small proportion of PP, whereas the visceral side consists of PVDF on the surface.

The mesh implant must be placed in such a way that the green filament ends are always oriented towards the abdominal wall. At the same time, the mesh implant must be oriented so that the green filament ends are cranial or caudal.

 

DM-IPOM_intraoperativei

Intraoperative view

 

Specifications
Product DynaMesh®-IPOM (1)
DynaMesh®-IPOM visible (2)
Surgical Treatment Umbilical Hernias / Epigastric Hernias /
Incisional Hernias / Parastomal Hernias
Surgical Approach Minimally Invasive / Open
Mesh Position Intraperitoneal* according to the intraperitoneal onlay mesh technique (IPOM).
Fixation Suture / Tacks / No Fibrin Glue
Green Filament Ends gruene_punkte
Visible Technology graue_punkte (1) / gruene_punkte (2)
Materials – Polyvinylidene fluoride (PVDF) (CAS 24937-79-9) > 85% (w/w) (1) (2)
– Polypropylene (PP) (CAS 9003-07-0) < 13% (w/w) (1) (2)
– Phthalocyanine green (CAS 1328-53-6) < 1% (w/w) (1) (2)
– Triiron tetraoxide (CAS 1317-61-9) < 1% (w/w)  (2)
Polymers (Monofilament) PVDF, PP
Biocompatibility
gruene_punkte[TR1]
Ageing Resistance
gruene_punkte[2A, 5VIT, 27A, 52VIT, 93A, 101]
Tear Propagation Resistance
gruene_punkte[TR62]
Effective Porosity
gruene_punkteHigh effective porosity reduces inflammation and the risk of excessive scar formation. [103P, TR64]
Klinge’s Mesh Classification Class 1a [102P, TR64]
* In particular cases with an extraperitoneal mesh position in which there is a risk of contact between the mesh implant and the intestine, the device may also be placed extraperitoneally in onlay, sublay and/or preperitoneal mesh position.
gruene_punkte Applies to all product sizes
gaue_punkte Does not apply
[#] Reference “#” (see “References”)
[TR#] Internal test report (see “internal test report references”)
Limitations “A” animal trial, “B” bench test, “VIT” in-vitro trial,
“P” published results based on the analysis of human mesh explants,
“PB” published results mainly based on bench tests

DynaMesh®-IPOM and DynaMesh®-IPOM visible implants have a parietal side and a visceral side. The parietal side is identified by green filament ends and consists of PVDF on the surface and a small proportion of PP, whereas the visceral side consists of PVDF on the surface.

Click here to download Catalogue

Reviews

There are no reviews yet.

Be the first to review “DynaMesh-IPOM”

Your email address will not be published. Required fields are marked *

Quick Comparison

DynaMesh-IPOM removeElastomeric Pump (Disposable Infusion Pump) with PCA removePortable Stainless Steel Autoclave Sterilizer removeDe Lineb Oxygen Face Mask removeSpinal Epidural Pack removeBettermed BT667E Electric Operating Table remove
NameDynaMesh-IPOM removeElastomeric Pump (Disposable Infusion Pump) with PCA removePortable Stainless Steel Autoclave Sterilizer removeDe Lineb Oxygen Face Mask removeSpinal Epidural Pack removeBettermed BT667E Electric Operating Table remove
Image
SKUSF1033560130161-4SF1033560084-18SF1033560084-4SF1033560084-39SF1033560084-25SF1033560084-50
Rating
Price

$0.00

$0.00

$216.00

$1.40

$0.00

$2,178.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad DynaMesh®-IPOM and DynaMesh®-IPOM visible implants are intended for the surgical treatment of epigastric hernias, umbilical or incisional hernias, and the treatment of parastomal hernias following ostomy surgery, and permanently bridge and reinforce the soft tissue of the abdominal wall in the area of the abdominal wall defect.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock This product make the tension of silicon capsule as the driving force to control the flow by micro porous tube, it was pre-selected by doctor base on patients'situation, and then and then handed over to the patients ' self- management “to relieve or ease the pain

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock
  • Can be set as required sterilization temperature, working tem. range:room tem.:+5~126 Degree.
  • Can ge set as required sterilization time of heat preservation, setting range:1~99min.
  • Having a low water to stop heating function.
  • This product uses the high quality stainless steel SUS304. Having to work under normal conditions adequate safety strength.
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
De Lineb Oxygen Face Mask: This mask provides a method to transfer breathing oxygen gas from a storage tank to the lungs. Oxygen masks may cover only the nose and mouth (oral nasal mask) or the entire face (full-face mask).
  Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock It is for performing spinal/epidural or combined spinal/epidural or never-block loco-regional anaesthesia on patinet in clinical surgery.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock This operation table is used for the surgeries of chest ,abdomen ,ophthalmology,obstetrics,and urology.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
DynaMesh®-IPOM and DynaMesh®-IPOM visible implants are primarily made of polyvinylidene fluoride (PVDF). The mesh implants are warp-knitted using coloured and uncoloured polyvinylidene fluoride (PVDF) monofilaments and uncoloured polypropylene (PP) monofilaments.   Positioning DynaMesh®-IPOM and DynaMesh®-IPOM visible implants have a parietal side and a visceral side. The parietal side is identified by the green filament ends and consists of PVDF on the surface and a small proportion of PP, whereas the visceral side consists of PVDF on the surface. The mesh implant must be placed in such a way that the green filament ends are always oriented towards the abdominal wall. At the same time, the mesh implant must be oriented so that the green filament ends are cranial or caudal.  

DM-IPOM_intraoperativei

Intraoperative view

 
Specifications
Product DynaMesh®-IPOM (1) DynaMesh®-IPOM visible (2)
Surgical Treatment Umbilical Hernias / Epigastric Hernias / Incisional Hernias / Parastomal Hernias
Surgical Approach Minimally Invasive / Open
Mesh Position Intraperitoneal* according to the intraperitoneal onlay mesh technique (IPOM).
Fixation Suture / Tacks / No Fibrin Glue
Green Filament Ends gruene_punkte
Visible Technology graue_punkte (1) / gruene_punkte (2)
Materials – Polyvinylidene fluoride (PVDF) (CAS 24937-79-9) > 85% (w/w) (1) (2) – Polypropylene (PP) (CAS 9003-07-0) < 13% (w/w) (1) (2) – Phthalocyanine green (CAS 1328-53-6) < 1% (w/w) (1) (2) – Triiron tetraoxide (CAS 1317-61-9) < 1% (w/w)  (2)
Polymers (Monofilament) PVDF, PP
Biocompatibility
gruene_punkte[TR1]
Ageing Resistance
gruene_punkte[2A, 5VIT, 27A, 52VIT, 93A, 101]
Tear Propagation Resistance
gruene_punkte[TR62]
Effective Porosity
gruene_punkteHigh effective porosity reduces inflammation and the risk of excessive scar formation. [103P, TR64]
Klinge’s Mesh Classification Class 1a [102P, TR64]
* In particular cases with an extraperitoneal mesh position in which there is a risk of contact between the mesh implant and the intestine, the device may also be placed extraperitoneally in onlay, sublay and/or preperitoneal mesh position.
gruene_punkte Applies to all product sizes
gaue_punkte Does not apply
[#] Reference “#” (see “References”)
[TR#] Internal test report (see “internal test report references”)
Limitations “A” animal trial, “B” bench test, “VIT” in-vitro trial, “P” published results based on the analysis of human mesh explants, “PB” published results mainly based on bench tests
DynaMesh®-IPOM and DynaMesh®-IPOM visible implants have a parietal side and a visceral side. The parietal side is identified by green filament ends and consists of PVDF on the surface and a small proportion of PP, whereas the visceral side consists of PVDF on the surface.

Click here to download Catalogue

This product make the tension of silicon capsule as the driving force to control the flow by micro porous tube, it was pre-selected by doctor base on patients'situation, and then and then handed over to the patients ' self- management “to relieve or ease the pain Product Components: one-way valve medicated device, elastic liquid storage device, liquid medicine filter, current limiting device, automatic liquid feeding device ( CBI & PCA ), pipe and the external connector; Product Features: 1. The continued to liquid (CBI) make the drug-stored sac mechanical stretch as a driving force, limited the flow through the micro porous tube to the patient safely, effectively, slightly, continuous uniform injection of liquid to analgesic effect; extrusion pump body does not affect the liquid normal velocity; liquid filtering device which can control the particles enter the body better; 2. Continued to liquid + self control to liquid ( CBI+PCA ) make the drug-stored sac mechanical stretch as a driving force, limited the flow through the micro porous tube to the patient safely, effectively, slightly, continuous uniform injection of liquid to analgesic effect; Automatic medicated function is the patients can medicate according to pain independently. Extrusion pump body does not affect the liquid normal velocity; liquid filtering device which can control the particles enter the body better; How to use: 1. Get analgesia pump out from sterile packaging, removing the cap of medicine inlet and outlet; pour the analgesic liquid in the liquid storage device, draw out the air from the liquid storage. 2. Finish medicating, waiting for the liquid outflow from the medicine outlet; please clamp tightly to stop flowing for preparation. 3. Control keys (PCA key) is a function key to add the medicine base on continue to medicated by patients' self-controlled. So the patients can self-control the PCA key under the guidance of doctors, according to the needs while they are in treatment. At the same time, doctor should fill in PCA treatment card, so that they can analyze the condition from PCA additional times.Features:
  • Can be set as required sterilization temperature, working tem. range:room tem.:+5~126 Degree.
  • Can ge set as required sterilization time of heat preservation, setting range:1~99min.
  • Having a low water to stop heating function.
  • This product uses the high quality stainless steel SUS304. Having to work under normal conditions adequate safety strength.
Technical Specifications:
Model No.: YX280A
Sterilizing volume 18L
Working pressure 0.14-0.16Mpa
Working temperature 126ºC
Max. safety pressure 0.165Mpa
Characteristics Electric heated
De Lineb Oxygen Face Mask: This mask provides a method to transfer breathing oxygen gas from a storage tank to the lungs. Oxygen masks may cover only the nose and mouth (oral nasal mask) or the entire face (full-face mask).
Features:
  • Non-toxic PVC
  • Medium concentration
  • Adjustable nose clip
  • Non-Autoclavable
  • Available size: adult, child
  Technical Specifications:
  • Product Name: Oxygen Mask
  • Material: Medical grade PVC
  • Color: Green
  • Size: S, M, L, L , XL
  • Package: PE bag
  • Tube size: 2m
  • Nose Clip: adjustable
  • Disposable Medical Oxygen Face Mask Types MSLMK01
 
It is for performing spinal/epidural or combined spinal/epidural or never-block loco-regional anaesthesia on patinet in clinical surgery. Component:
  • Epidural needle 16G,
  • Epidural catheter,
  • Epidural filter 0.2 um,
  • Catheter connector,
  • LOR syringe
This operation table is used for the surgeries of chest, abdomen, ophthalmology, obstetricsand urology, etc.It has the following advantages: ●The board can shift longitudinally. It is made of Transparent material material.it can be X-rayed or scan when using along with C-ARM . ●The board is controlled by electric handspike to move up and down, lean from left to right and move back and forth. ●The leg board is dismantable. It is manual rotation and could be ooutreached with the force from the spring and gravity, convenient for urology surgery. Technical Specification
●Material: 304stainless steel ●Reverse Trendelenburg:25° ●Lateral Adjustment:20° ●Longitudinal displacement:300mm ●Headrest adjust:- 90°~+45° ●Backrest adjust:- 10°~+60° ●Waist bridge: 100mm ●Leg plate(s): 90° ●Swiveling of leg plate:90° ●Standard accessory: anesthesia screen, the shoulder rest, arm support ,body support, Knee crutch ,mattress.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare