Exhaled Nitric Oxide Detector

$3,850.00

Shipped From Abroad

Exhaled nitric oxide detection is to measure the concentration of NO in human exhaled breath, referred to as FeNO detection

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130159-6
Brands:: Ancool

Description

Exhaled Nitric Oxide Analyzer

The test can be performed with just 10 seconds of exhalation, and the test analysis time only takes 60 seconds.

For common diseases in departments such as respiratory medicine, pediatrics, otolaryngology, physical examination, and allergy, such as cough, asthma, chronic obstructive pulmonary disease, etc., during routine clinical examinations, it helps doctors to safely, quickly, and conveniently identify the type of inflammation, assess the level of inflammation, guide treatment, and monitor prognosis.

Detection principle:

Nitric oxide can be produced by a variety of intrinsic cells and inflammatory cells on the surface of the airways under the oxidation of nitric oxide synthase. Allergens and other stimuli induce airway inflammation, and cells such as eosinophils (EOS) release cytokines, activate nitric oxide synthase, and increase airway nitric oxide levels. Currently, FeNO detection can be used to identify chronic airway diseases with similar clinical manifestations such as COPD, asthma, and asthma -COPD overlap syndrome, and can be used to predict the treatment effect and prognosis of COPD patients. FeNO detection helps to improve the diagnosis and treatment of airway inflammatory diseases and can raise the clinical management level of airway inflammation to a new level. FeNO detection has the advantages of accurate results, reliable data, and good repeatability. It is an ideal non-invasive examination technology for airway inflammatory diseases.

Note:

1. Avoid eating, drinking, smoking, strenuous exercise, lung function, or other tests within 1 hour before sampling.

2. Avoid eating foods rich in nitrates or nitrites, such as broccoli, kale, lettuce, celery, radish, and smoked, pickled, or grilled foods within 3 hours.

3. Also ask and record the test time, medication, etc.

Reviews

There are no reviews yet.

Be the first to review “Exhaled Nitric Oxide Detector”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsExhaled Nitric Oxide Detector removeMaico EasyScreen ABR + OAE Combined in One Hearing Screen Device removeMaico ERO•SCAN Otoacoustic Emission (OAE) Screener removeMIR Spirodoc – Spirometer with Oximeter removeM.I One ENT Treatment Chair (IC-3000) removeMaico TouchTymp MI36 Tympanometry remove
NameExhaled Nitric Oxide Detector removeMaico EasyScreen ABR + OAE Combined in One Hearing Screen Device removeMaico ERO•SCAN Otoacoustic Emission (OAE) Screener removeMIR Spirodoc – Spirometer with Oximeter removeM.I One ENT Treatment Chair (IC-3000) removeMaico TouchTymp MI36 Tympanometry remove
ImageMaico EasyScreen ABR + OAE Combined in One Hearing Screen DeviceMaico ERO•SCAN Otoacoustic Emission (OAE) ScreenerMIR Spirodoc with pulse oximetryMaico TouchTymp MI36 Tympanometry and Amp
SKUSF1033560130159-6SF1033560063-1SF1033560063-3SF10335601290SF10335601262SF1033560063-10
Rating
Price

$3,850.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Exhaled nitric oxide detection is to measure the concentration of NO in human exhaled breath, referred to as FeNO detection
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad
The easyScreen unites ABR, TEOAE and DPOAE screening capabilities in one device to meet your need for a cost efficient 2-step ABR/OAE Hearing Screener. easyScreen will lighten your daily workload in many ways: the device fits right into your pocket and helps you save time with its binaural automated ABR screening to test both ears at the same time. The integrated CE-Chirp® stimulus generates accurate pass or refer results within seconds. The device is easy to operate and allows even first-time users to achieve the most accurate results thanks to its on-screen guidance.
  Delivery & Availability: Typically 10 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad
ERO•SCAN® provides automated tests with 2 DPOAE and 2 TEOAE screening protocols. Ideal for professionals involved in a hearing screening program or who need a quick assessment of the cochlear system with “Pass” or “Refer” outcomes. An excellent solution for screening newborn, infant, pre-school and nursery children.
  Delivery & Availability: Typically 10 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock
The MIR  Spirodoc™ Touchscreen Spirometer with Oximeter is a high quality, portable spirometer used for measuring lung function, as well as measuring oxygen saturation. Delivery & Availability: Typically 7-14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
The IC-3000 ENT treatment chair features electrical height adjustment which is foot controlled, along with adjustable and removable armrests. Other features include 360° rotation (position lock), adjustable backrest from vertical to horizontal position, and an articulated headrest. Delivery & Availability: Typically 14-21 Working Days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad TouchTymp MI 36 combines diagnostic middle ear analyzer and audiometry tests in one exceptional device. The full 10.4" touchscreen with its user-friendly interface guarantees a unique intuitive operation and allows to quickly change parameters. You can easily switch between the tests without reorganizing from one to another device and beneft from its small footprint when facing limited desk space. touchTymp MI 36 really improves your workflow every day. Delivery & Availability: Typically 10 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Exhaled Nitric Oxide Analyzer
The test can be performed with just 10 seconds of exhalation, and the test analysis time only takes 60 seconds. For common diseases in departments such as respiratory medicine, pediatrics, otolaryngology, physical examination, and allergy, such as cough, asthma, chronic obstructive pulmonary disease, etc., during routine clinical examinations, it helps doctors to safely, quickly, and conveniently identify the type of inflammation, assess the level of inflammation, guide treatment, and monitor prognosis.
Detection principle:
Nitric oxide can be produced by a variety of intrinsic cells and inflammatory cells on the surface of the airways under the oxidation of nitric oxide synthase. Allergens and other stimuli induce airway inflammation, and cells such as eosinophils (EOS) release cytokines, activate nitric oxide synthase, and increase airway nitric oxide levels. Currently, FeNO detection can be used to identify chronic airway diseases with similar clinical manifestations such as COPD, asthma, and asthma -COPD overlap syndrome, and can be used to predict the treatment effect and prognosis of COPD patients. FeNO detection helps to improve the diagnosis and treatment of airway inflammatory diseases and can raise the clinical management level of airway inflammation to a new level. FeNO detection has the advantages of accurate results, reliable data, and good repeatability. It is an ideal non-invasive examination technology for airway inflammatory diseases. Note: 1. Avoid eating, drinking, smoking, strenuous exercise, lung function, or other tests within 1 hour before sampling. 2. Avoid eating foods rich in nitrates or nitrites, such as broccoli, kale, lettuce, celery, radish, and smoked, pickled, or grilled foods within 3 hours. 3. Also ask and record the test time, medication, etc.
The easyScreen unites ABR, TEOAE and DPOAE screening capabilities in one device to meet your need for a cost efficient 2-step ABR/OAE Hearing Screener. easyScreen will lighten your daily workload in many ways: the device fits right into your pocket and helps you save time with its binaural automated ABR screening to test both ears at the same time. The integrated CE-Chirp® stimulus generates accurate pass or refer results within seconds. The device is easy to operate and allows even first-time users to achieve the most accurate results thanks to its on-screen guidance.
Features:
  • Fast and accurate ABR + OAE Hearing Screening
  • Powerful automated ABR Screening method with CE-Chirp® stimulus
  • Intuitive user interface and large color touchscreen
  • Pocke tsized and lightweight
  • HearSIM™ patient database and device manager
 
Click Here To Download Catalogue
ERO•SCAN® provides automated tests with 2 DPOAE and 2 TEOAE screening protocols. Ideal for professionals involved in a hearing screening program or who need a quick assessment of the cochlear system with “Pass” or “Refer” outcomes. An excellent solution for screening newborn, infant, pre-school and nursery children. Features:
  • Fast automatic OAE screening with Pass/Refer results and graphical displays
  • 2 DP and 2 TE protocols for screening devices, 5 DP and 3 TE protocols for diagnostic devices
  • High noise immunity for operation in normal clinical environment
  • Lightweight, small ear probe
  • Sharp colored Organic LED display
  • Wireless communication to PC and optional printer
 
Click Here To Download Catalogue
The MIR  Spirodoc™ Touchscreen Spirometer with Oximeter is a high quality, portable spirometer used for measuring lung function, as well as measuring oxygen saturation. The Touchscreen Spirometer is ideal for lung and asthma specialty offices, as well as hospitals and clinics.The Desktop Spirometer features a bright, easy to read backlit LCD touchscreen display and a flowmeter head which can detach from the touchscreen to facilitate an oximetry test.
  • Touch screen.
  • Non-invasive.
  • Detachable flowmeter head to facilitate oximetry tests.
  • Spot oximetry test.
  • 24 hour Holter test.
  • Patient eDiary.
  • On-screen results and curves preview for immediate data assessment.
  • Home care symptoms diary.
  • 6MWT (6-Minute Walk Test).
  • Triaxial Accelerometer.
  • Capable of sleep desaturation study.
  • Respiratory Rehabilitation Monitoring.
  • Activity Monitoring.
  • Long life, rechargeable battery.
  • Traffic light health indicator for immediate test interpretation.
  • Wireless real time test on PC via Bluetooth.
  • May be used for both home and office use.
  • Unit:
    • Display: LCD backlit touch screen.
    • Resolution: 128 x 64 pixels.
    • Power Supply: Lithium Ion 3.7 V 1100 mA rechargeable battery.
    • Data Transmission: USB 2.0 on-the-go and Bluetooth 2.1.
    • Accelerometer: Triaxial ± 2 g. 400 Hz sampling.
    • Dimensions: 101 mm x 48 mm x 16 mm.
    • Weight: 0.22 lb (99 g).
    • Removable Turbine Head Dimensions: 46 mm x 47 mm x 24 mm.
    • Removable Turbine Head Weight: 17 g.
  • Spirometer:
    • Flow Sensor: Bi-directional digital turbine.
    • Flow Range: ± 16 L/s.
    • Volume Accuracy: ± 3% or 50 mL, whichever is greater.
    • Flow Accuracy: ± 5% or 200 mL/s, whichever is greater.
    • Dynamic Resistance at 12 L/s: < 0.5 cmH2O/L/s.
    • Temperature Sensor: Semiconductor (0 - 45 degrees C).
  • Pulse-Oximeter:
    • SpO2 Range: 0 - 99%.
    • SpO2 Accuracy: ± 2 % (70 - 99% SpO2).
    • Heart Rate Range: 30 - 254 BPM.
    • Heart Rate Accuracy: ± 2 BPM or 2%, whichever is greater.
 
Click Here To Download Catalogue
The IC-3000 ENT treatment chair features electrical height adjustment which is foot controlled, along with adjustable and removable armrests. Other features include 360° rotation (position lock), adjustable backrest from vertical to horizontal position, and an articulated headrest. Features: - Convenient 5 position button Backrest Side Control Button Bottom Memory Button Backrest Rotation Button Backrest Control Button Armrest Turn Control Button - Electrical gear Driven Technical Specifications: Power Source: 220V AC, 50/60Hz Power Consumption: 400W Rotation: 3600 Electronic Brake system Up-Down Stroke: 300mm + 10%, Lifting Mechanism (Motor Support) Range of Back-Rest Movement: 0~900 Electronic Linear Actuator Headrest: Up/Down By Manual Dimension: W653xD881xH1278 Weight: Approx 120kg Arm-Rest: 0~900 by Manual Foot Switch: Up/Down/Front/Rear Remote Control: Hand Type, Up/Down/Front/Rear/Memory x 2Sit Position Memory x 4TouchTymp MI 36 combines diagnostic middle ear analyzer and audiometry tests in one exceptional device. The full 10.4" touchscreen with its user-friendly interface guarantees a unique intuitive operation and allows to quickly change parameters. You can easily switch between the tests without reorganizing from one to another device and beneft from its small footprint when facing limited desk space. touchTymp MI 36 really improves your workflow every day. FEATURES AT A GLANCE
  • Combo device with small footprint
  • Customizable to suit individual needs
  • High resolution and quick screen transitions
  • Full touch-based interface for intuitive handling
  • Probe tone 226 Hz, 678 Hz, 800 Hz
  • Optional high-frequency probe tone 1 kHz
  • Acoustic reflex stimuli 500 Hz,1 kHz, 2 kHz, 4 kHz, BB, HP, LP (ipsilateral and contralateral)
  • Reflex Decay test (ipsilateral and contralateral)
  • ETF test for intact and perforated eardrums
  • Air conduction audiometry
  • Bone conduction audiometry
  • Built-in printer or data transfer to PC
  • Optional MAICO Sessions PC Software connectable with OtoAccess® or Noah patient database for easy data management
Comprehensive test protocols
  • Our touchTymp MI 36 provides comprehensive standard protocols for immediate operation of screening and diagnostic test processes: tympanometry with 226 Hz, tympanometry with automatic or fxed acoustic reflexes, reflex decay, Eustachian tube function testing (ETF) plus air conduction and bone conduction audiometry. The optional high-frequency probe tone of 1 kHz is ideal for providing reliable results when testing newborns
Stay focused on your patients
  • The unique touchTymp light bar on our shoulder box probe provides a real-time progression of the immittance test. The shoulder box can easily be clipped to your patient's top for controlled handling of the diagnostic probe. The light indicator shows you which ear is tested and the test result.
Printing made easy
  • Print test results instantly by using the touchTymp built-in printer. Place the shoulder box into its holder to automatically start printing. You can transfer the results to a PC to allow long term storage, full page printout and PDF creation for EMR integration.
Compatible to Sessions: Get ready for fast data transfer!
  • Use the touchTymp MI 36 with our intuitive data transfer solution Sessions, for easy management and visualization of your immittance measurements.
  TECHNICAL SPECIFICATION Tympanometry
  • Probe Frequency - 226 Hz ± 1 %, 85 dBSPL ± 1.5 dB, 678 Hz ± 1%, 72 dBSPL ± 1.5 dB, 800 Hz ± 1%, 70.5 dBSPL ± 1.5 dB
  • Optional High Frequency - 1 kHz ± 1%, 69 dBSPL ± 1.5 dB
  • Pressure Range - -600 to + 400 daPa
  • Accuracy of Pressure - ± 5 % or ± 10 daPa
  • Volume Range - 0.0 to 6.0 ml (compensated)
  • Compliance Range - 0.1 to 8.0 ml at 226 Hz, 0.1 to 15.0 mmho at 678, 800 and 1000 Hz
  • Accuracy of Volume - ± 5 % or 0.1 ml
  • Test Time Measurement - 3 - 5 seconds
Acoustic Reflexes
  • Test Frequencies - 0.5, 1, 2, 4 kHz ± 1 %
  • Test Noise - BB, LP, HP
  • Test Methods - Ipsilateral, contralateral
  • Level Ipsilateral - 70 to 105 dBHL
  • Level Contralateral - 70 to 120 dBHL
  • Level Setting - Automatic, fxed
  • Ipsilateral Reflex - Test With AGC
Reflex Decay
  • Standard - Probe frequency 226 Hz
  • Test Frequencies - 0.5, 1, 2, 4 kHz ± 1 %
  • Test Noise - BB, LP, HP
  • Level Ipsilateral - 70 to 105 dBHL
  • Level Contralateral - 70 to 120 dBHL
Eustachian Tube Function
  • Test Methods - Intact and perforated
  • Pressure Range - -600 to + 400 daPa
Audiometry
  • Test Signals - Sinus and warble tone, (pulsed and continuous)
  • Test Frequencies - 125, 250, 500, 750, 1000, 1500, 2000, 3000, 4000, 6000, 8000 Hz (125 Hz excluded
  • from bone conduction test frequencies)
  • Level Steps - 5 or 1 dB
  • Hearing Level Range AC - -10 to 120 dBHL
  • Hearing Level Range BC -  -10 to 80 dBHL
  • Masking Noise - Narrow band and white noise
Device General
  • Display - 10.4" Graphic LED-Display with resistive touchscreen
  • PC Interface - USB
  • Probe - Lightweight diagnostic Shoulder-Box with built-in control light and switch
  • Printer - Fast 4 inch thermal printer
  • Power Supply - Mains 100 to 240 V~ ± 10 %, 50 - 60 Hz ± 10 %
  • Dimensions / Weight - W 30 x D 34.5 x H 14.8 cm / 3.2 kg
  • Languages - English, German, Spanish, French, Polish, Turkish, Russian, Chinese
 
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare